470 - 516 MHz Informations complmentaires concernant les systmes evolution wireless ew G3 Les metteurs et les rcepteurs sont disponibles dans une plage de frquences UHF de 46 MHz de largeur, ce qui autorise un choix parmi 1840 frquences dmission et de rception. 470 - 516 MHz Informacin adicional para sistemas Senn-
heiser de la serie evolution wireless G3 Para la transmisin se dispone de un rango de frecuencia de 46 MHz de amplitud con 1840 frecuencias de transmisin/
recepcin posibles en la banda UHF. 470 - 516 MHz Zusatzinformation fr Sennheiser Systeme der Serie evolution wireless G3 Fr die bertragung steht im UHF-Band ein 46 MHz breiter Frequenzbereich mit 1.840 mglichen Sende-/Empfangsfre-
quenzen zur Verfgung. 470 - 516 MHz Additional information for Sennheiser evo-
lution wireless G3 systems Transmitters and receivers are available in a 46 MHz UHF fre-
quency range with a total of 1,840 transmission/receiving frequencies. Les metteurs et les rcepteurs possdent 20 banques de fr-
quences, dans lesquelles chaque canal est prrgl en usine sur une frquence. Les frquences prrgles au sein dune banque de frquence sont compatibles entre elles, c..d. ex-
emptes dintermodulation. Elles ne peuvent pas tre modi-
fies. La banque de frquences U (ew 100 G3) et les banques de frquences U1 U6 (ew 300 IEM G3) permettent de mmoriser des frquences au choix, qui peuvent tre rgles par pas de 25 kHz. Il se peut que ces frquences ne soient pas exemptes dintermodulation. Le tableau suivant dresse la liste des frquences prrgles dans les banques de frquences 1 20 :
Srie ew 100 G3 : les 12 premiers canaux dune banque Srie ew 300 IEM G3 : les 16 premiers canaux dune ban-
que Les paramtres par dfaut suivants, prrgls en usine, peu-
vent tre restaurs tout moment via loption Reset. Los transmisores y receptores cuentan con 20 bancos de canales cada uno para los que se ha preajustado una frecuen-
cia en fbrica. Dentro de un banco de canales, los preajustes de frecuencia se encuentran libres de intermodulacin entre ellos. stos no se pueden cambiar. En el banco de canales U (ew 100 G3) y en los bancos de canales U1 hasta U6 puede ajustar libremente y guardar frecuencias a pasos de 25 kHz. Estas frecuencias pueden no estar libres de intermodulacin. Los preajustes de frecuencia en los bancos de canales 1 a 20 se representan en la siguiente tabla:
Serie ew 100 G3: los primeros 12 canales de cada banco de canales Serie ew 300 IEM G3: los primeros 16 canales de cada banco de canales Con la opcin de men Reset, se pueden llamar de nuevo los siguientes ajustes de fbrica en todo momento. Die Sender und Empfnger verfgen ber jeweils 20 Kanal-
bnke, auf denen werkseitig eine Frequenz voreingestellt ist. Innerhalb einer Kanalbank sind die Frequenz-Presets unterei-
nander intermodulationsfrei. Sie sind nicht vernderbar. In der Kanalbank U (ew 100 G3) bzw. den Kanalbnken U1 bis U6 (ew 300 IEM G3) knnen Sie in 25-kHz-Schrit-
ten Frequenzen frei einstellen und abspeichern. Diese sind unter Umstnden nicht intermodulationsfrei. Die Frequenz-Presets in den Kanalbnken 1 bis 20 sind in der folgenden Tabelle dargestellt:
ew 100 G3 Serie: die ersten 12 Kanle je Kanalbank ew 300 IEM G3 Serie: die ersten 16 Kanle je Kanalbank Folgende Werkseinstellungen sind mit dem Menpunkt Reset jederzeit wieder abrufbar. Transmitters and receivers have 20 frequency banks respec-
tively. Each of the channels in the frequency banks has been factory-preset to a frequency. The frequency presets within one frequency bank are intermodulation-free. These frequen-
cies cannot be changed. The frequency bank U (ew 100 G3) and the frequency banks U1 to U6 (ew 300 IEM G3) allow the user to store individual frequencies which are freely selectable in 25-kHz steps. It might be that these frequencies are not intermodu-
lation-free. The following table lists the frequency presets in the frequen-
cy banks 1 to 20:
ew 100 G3 series: the first 12 channels in a frequency bank ew 300 G3 IEM series: the first 16 channels in a frequency bank The following factory-preset default settings can be recalled any time via the Reset menu item. ew 100 G3 Auto Lock Sensitivity Mute Mode Squelch AF Out Equalizer Guitar Tuner Name Pilot Tone User Bank
-30 dB
-18 dB inactive SK SKM AF On/Off (SK) low/5 dBV EM EK flat inactive Name of series will not be reset will not be reset
+18 dB 0 dB ew 300 IEM G3 Auto Lock Squelch (EK) Sensitivity (SR) RF Power (SR) Limiter Mode Balance (EK) High Boost (EK) Pilot Tone User Banks Sync Settings (SR) Warnings (SR) IP Address (SR) inactive 5 dB
-18 dB Standard active, -6 dB Stereo 0 flat will not be reset will not be reset inactive active automatic ew 100 G3 Auto Lock Sensitivity Mute Mode Squelch AF Out Equalizer Guitar Tuner Name Pilot Tone User Bank
-30 dB
-18 dB inactive SK SKM AF On/Off (SK) low/5 dBV EM EK flat inactive Name of series will not be reset will not be reset
+18 dB 0 dB ew 300 IEM G3 Auto Lock Squelch (EK) Sensitivity (SR) RF Power (SR) Limiter Mode Balance (EK) High Boost (EK) Pilot Tone User Banks Sync Settings (SR) Warnings (SR) IP Address (SR) inactive 5 dB
-18 dB Standard active, -6 dB Stereo 0 flat will not be reset will not be reset inactive active automatic 571305_0316_ewG3_A1_PRT.indd 1 29.04.2016 11:29:38 Sennheiser electronic GmbH & Co.KG Am Labor 1, 30900 Wedemark, Germany www.sennheiser.com Printed in Germany Publ. 03/16, 571305/A01 470 - 516 MHz Frequenzbereich / Frequency range / Bande de frquence / Rango de frecuencias A1 US TV Channels Ch. 14 (470-476 MHz) Ch. 15 (476-482 MHz) Ch. 16 (482-488 MHz) Ch. 17 (488-494 MHz) Ch. 18 (494-500 MHz) Ch. 19 (500-506 MHz) Ch. 20 (506-512 MHz) Ch. 21 (512-518 MHz) Channel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Channel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Bank 1 470,100 470,500 471,050 471,750 472,200 472,800 473,650 474,750 475,250 506,150 506,950 511,000 508,500 512,300 514,350 515,550 Bank 11 470,800 471,250 472,250 472,950 473,450 474,300 474,950 475,350 475,900 486,050 486,850 487,450 488,600 508,000 511,000 506,700 Bank 2 476,100 476,500 477,050 478,200 488,100 488,600 489,450 490,050 491,050 491,800 492,250 492,900 473,200 506,150 508,250 511,800 Bank 12 471,200 471,600 472,150 472,850 473,300 473,900 474,650 475,850 488,250 490,700 491,350 492,250 507,700 510,350 509,550 511,800 Bank 3 488,100 488,500 489,050 489,750 490,200 490,800 491,550 492,750 506,100 507,200 509,250 510,700 511,600 502,300 505,600 510,050 Bank 13 471,200 471,600 472,150 472,850 473,300 473,900 474,650 475,850 488,250 490,700 491,350 492,250 507,250 509,600 510,400 511,800 Bank 4 494,100 494,500 495,050 495,750 496,200 496,800 497,550 498,750 499,750 471,400 473,750 474,250 475,150 475,800 470,100 504,850 Bank 14 488,400 488,800 489,250 489,750 490,300 490,900 491,550 492,300 493,100 476,500 477,200 478,200 510,400 508,650 506,250 511,300 Bank 5 500,100 500,500 501,050 501,750 502,200 502,800 503,600 504,800 505,650 471,700 472,450 474,350 475,650 470,250 478,050 480,300 Bank 15 494,600 495,000 495,450 495,950 496,500 497,100 497,750 498,950 499,750 476,350 477,100 478,100 502,150 505,100 505,800 504,200 Bank 6 506,100 506,500 506,950 507,450 508,000 508,600 509,250 510,000 510,800 511,700 470,100 474,950 481,500 471,700 477,100 473,000 Bank 16 506,400 506,800 507,250 507,750 508,300 508,900 509,550 510,350 511,250 500,850 501,850 503,400 474,850 473,100 470,950 470,200 Bank 7 470,200 470,600 471,150 471,850 472,300 472,900 473,650 474,850 506,300 508,550 509,400 511,750 504,250 503,350 501,500 504,900 Bank 17 471,000 471,400 471,850 472,350 472,900 473,500 474,200 475,200 488,350 489,000 490,400 493,350 507,650 506,750 510,900 508,750 Bank 8 488,200 488,600 489,150 489,850 490,700 491,300 492,600 493,050 470,250 470,750 472,250 473,050 477,750 482,900 475,500 483,950 Bank 18 471,500 471,900 472,350 472,850 473,400 474,000 474,650 475,850 494,750 495,750 496,450 498,650 501,300 505,050 503,650 502,100 Bank 9 476,200 476,600 477,150 477,850 478,300 506,800 507,700 508,350 509,550 510,300 510,900 511,700 502,850 500,850 500,350 503,900 Bank 19 488,550 488,950 489,400 489,900 490,450 491,050 491,700 492,500 493,400 471,150 472,700 475,550 506,950 511,550 506,250 510,150 Bank 10 488,400 488,850 489,450 490,300 490,800 491,450 492,350 493,050 493,600 471,500 473,150 474,150 485,700 484,300 483,500 476,000 Bank 20 500,750 501,150 501,600 502,100 502,650 503,250 503,900 504,700 505,600 507,550 508,850 511,000 470,850 475,500 473,900 470,150 ew 100 G3: Channels 1 - 12 ew 300 IEM G3: Channels 1 - 16 Herstellererklrungen / Manufacturer Declarations /
Dclarations du fabricant / Declaraciones del fabricante Anforderungen werden erfllt fr / In compliance with /
Conformes aux normes / Se cumplen los requisitos para USA / tats-Unis / EE. UU. Kanada / Canada / Canad FCC 47 CFR Part 74 RSS - 123 Issue 1 Zugelassen fr / Approved by / Homologation pour / Homologado para USA / tats-Unis / EE. UU. Kanada / Canada / Canad SKM 100 SK 100 SKP 100 SR 300 IEM SKM 100 SK 100 SKP 100 SR 300 IEM FCC ID: DMOG3SKMEMU FCC ID: DMOG3SKU FCC ID: DMOG3SKPU FCC ID: DMOG3SREKU IC: 2099A-G3SKMEMU IC: 2099A-G3SKU IC: 2099A-G3SKP100U IC: 2099A-G3SREKU FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause un-
desired operation. This class B digital device complies with the Canadian ICES-003. Changes or modifications made to this equipment not expressly approved by Sennheiser electronic Corp. may void the FCC au-
thorization to operate this equipment. Before putting the device into operation, please observe the respective country-specific regulations!
Cet appareil est conforme la Partie 15 des rglementations de la FCC. Lutilisation de lappareil doit respecter les deux conditions suivantes : (1) Lappareil ne doit pas produire dinterfrences nuisibles, et, (2) il doit accepter toutes interferences reues, y compris celles qui pourraient avoir des effets non dsirs sur son fonctionnement. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. Toute modification non expressment approuve par Sennheiser electronic Corp. peut annuler le droit de lutilisateur lemploi de lquipement en question. SK, SKM, SP: For body-worn / hand-held operation, this device has been tested touched to the phantom and meets FCC RF exposure guidelines. SR 300 IEM: Radiofrequency radiation exposure information: This equipment complies with FCC and IC radiation exposure limits set forth for an uncontrolled environment. The SR 300 should be installed and operated with a minimum distance of 20 cm between the radiator and your body. Fr einen strungs- / intermodulationsfreien Betrieb empfehlen wir die aufgefhrten Frequenzen zu nutzen. Zur Berechnung alternativer Frequenzen steht Ihnen unser Wireless Systems Manager (WSM) auf unter www.sennheiser.com zur Verfgung. For operation free of interferences and intermodulations we recommend using the listed frequencies. For calculating alterna-
tive frequencies you can use our Wireless Systems Manager (WSM) which is available at www.sennheiser.com. Pour une opration libre dinterfrences et dintermodulations, nous vous recommandons dutiliser les frquences indiques. Pour calculer les frquences alternatives, notre Wireless Systems Manager (WSM) est disponible a www.sennheiser.com. Para una operacin libre de interferencias e intermodulaciones, se recomienda utilizar las frecuencias indicadas. Para calcualar frecuencias alternativas, est disponible nuesto Wireless Systems Manager (WSM) a www.sennheiser.com. 571305_0316_ewG3_A1_PRT.indd 2 29.04.2016 11:29:38