XS WIRELESS 1 Technische Daten Specifications Caractristiques techniques Dati tecnici Especificaciones tcnicas Dados tcnicos Technische specificaties Dane techniczne Tekniska data Tekniske data Tekniset tiedot
571314_0516_A01_TD_XSW1_SP15.indb 1 18.07.2016 14:46:30 Specifications System Modulation Frequency ranges wideband FM A: 548 to 572 MHz GB: 606 to 630 MHz B: 614 to 638 MHz C: 766 to 790 MHz D: 794 to 806 MHz E: 821 to 832 MHz and 863 to 865 MHz K: 925 to 937.5 MHz Switching bandwidth up to 24 MHz Frequencies Signal-to-noise ratio THD Temperature range 8 frequency banks, each with up to 10 factory-preset channels
103 dBA
0.9%
operation: 0C to +40C storage: 20C to +70C Transmitter synchronization 2.4 GHz, Low Power OQPSK (only active during synchronization) Receiver Receiver principle Diversity principle Sensitivity (at peak deviation) AF frequency response Max. AF output voltage
(at peak deviation, 1 kHz AF) double superheterodyne antenna switching diversity via internal antennas
< 3 V at 52 dB(A)rms S/N 50 to 16,000 Hz ( 3 dB) 1/4" (6.3 mm) jack socket (unbalanced): +6 dBu XLR socket (balanced): +12 dBu Audio adjustment range 45 dB, adjustable in 5-dB steps Power supply Squelch Line/Mic level Housing material 12 V DC nom. / 300 mA adjustable from 3 dBV to 28 dBV (combined with pilot tone) 20 dB, switchable rugged ABS housing Dimensions (W x H x D) approx. 200 x 42 x 127 mm Weight approx. 340 g E D N E R F T I S E T P L N L P E S K D I F R G U R H Z O K E C N A I L P M O C 571314_0516_A01_TD_XSW1_SP15.indb 1 18.07.2016 14:46:33 XS WIRELESS 1 | 1 Transmitters SK SKM 825 SKM 835 RF output power AF frequency response Audio input Max. input voltage
(Mic/Line) at 3% THD Power supply Operating time Microphone type Input sensitivity (capsule) Pick-up pattern Adjustment range of transmitter sensitivity Housing material Dimensions Weight 10 mW 80 to 14,000 Hz 80 to 16,000 Hz 50 to 16,000 Hz (Line) 80 to 16,000 Hz (Mic) 3.5 mm jack socket typ. 1.5 VRMS Mic/
typ. 2.6 VRMS Line
@ 30 dB Gain 2 AA size batteries, 1.5 V 2 AA size batteries, 1.5 V approx. 10 hours dynamic 1.5 mV/Pa cardioid 0 to 30 dB, adjustable in 10-dB steps rugged ABS housing approx. 71 x 96 x 28 mm
(W x H x D) approx. 95 g approx. 260 x 84 mm
(L x ) approx. 245 g Microphones ME 2-2 ME 3-II e 908T Transducer principle Sensitivity Pick-up pattern Max. SPL condenser, pre-polarized condenser, pre-polarized condenser, pre-polarized 20 mV/Pa 1.6 mV/Pa 0.6 mV/Pa omni-directional cardioid super-cardioid 130 dB 150 dB 147 dB 2 | XS WIRELESS 1 571314_0516_A01_TD_XSW1_SP15.indb 2 18.07.2016 14:46:34 In compliance with (EM, SK and SKM) Europe EMC Radio Safety EN 301489-1/-3/-9 EN 300422-2, EN 301440 EN 60065, EN 62311 (SAR) Approved by (EM) Canada:
USA:
Approved by (SK) Canada:
USA:
Approved by (SKM) Canada:
USA:
Industry Canada RSS 210, RSS 310 IC: 2099A-EMXSW1 FCC Part 15 B & C, FCC-ID: DMOEMXSW1 Industry Canada RSS 210, IC 2099A-SKXSW FCC-Part 74, FCC-ID: DMOSKXSW FCC-Part 15 C, limited to 698 MHz Industry Canada RSS 210, IC 2099A-SKMXSW FCC-Part 74, FCC-ID: DMOSKMXSW FCC-Part 15 C, limited to 698 MHz Connector assignment EM SK 1/4" (6.3 mm) mono jack plug XLR-3 connector 3.5 mm jack plug
+
2 1 3 E D N E R F T I S E T P L N L P E S K D I F R G U R H Z O K E C N A I L P M O C 571314_0516_A01_TD_XSW1_SP15.indb 3 18.07.2016 14:46:35 XS WIRELESS 1 | 3 NT 12-5CW power supply unit Nominal input voltage Power frequency Input current Nominal output voltage Standby power consumption Energy efficiency level Temperature range Storage temperature Relative air humidity Weight (without adapter) 100 to 240 V~
50 or 60 Hz max. 200 mA 12 V
0.1 W VI 0C to +40C 20C to +60C max. 95%
approx. 65 g In compliance with:
Europe USA/Canada China EMC Safety RoHs Energy efficiency level Commission Regulation
(EU) No. EMC Safety EN 55032, EN 55024 EN 60950-1 EN 50581 V 278/2009 and 1275/2008 FCC 47 CFR 15 B ICES 003, CAN ICES-3(B)/NMB-3(B) UL 60950-1 CAN/CSA-C22.2 No. 60950-1 Energy efficiency level DOE Level VI EMC Safety RoHS GB13837, GB17625 GB8898 Australia/New Zealand EMC Safety AS/NZS CISPR 22 AS/NZS 60950-1 4 | XS WIRELESS 1 571314_0516_A01_TD_XSW1_SP15.indb 4 18.07.2016 14:46:35 Manufacturer Declarations Warranty Sennheiser electronic GmbH & Co. KG gives a warranty of 24 months on this product. For the cur-
rent warranty conditions, please visit our website at www.sennheiser.com or contact your Sennheiser partner. FOR AUSTRALIA ONLY Sennheiser goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. This warranty is in addition to other rights or remedies under law. Nothing in this warranty excludes, limits or modifies any liability of Sennheiser which is imposed by law, or limits or modifies any remedy available to the consumer which is granted by law. To make a claim under this warranty, contact Sennheiser Australia Pty Ltd, Unit 3, 31 Gibbes Street Chatswood NSW 2067, AUSTRALIA. Phone: (02) 9910 6700, email: service@sennheiser.com.au. All expenses of claiming the warranty will be borne by the person making the claim. The Sennheiser International Warranty is provided by Sennheiser Australia Pty Ltd (ABN 68 165 388 312), Unit 3, 31 Gibbes Street Chatswood NSW 2067 Australia. In compliance with the following requirements WEEE Directive (2012/19/EU) Please dispose of the products at the end of their operational lifetime by taking them to your local collection point or recycling center for such equipment. Battery Directive (2013/56/EU) The supplied batteries can be recycled. Please dispose of them as special waste or return them to your specialist dealer. To protect the environment, only dispose of exhausted batteries. CE Declaration of Conformity RoHS Directive (2011/65/EU) Radio Equipment Directive (2014/53/EU) EMC Directive (2014/30/EU) Low Voltage Directive (2014/35/EU) The declaration is available at www.sennheiser.com. Before putting into operation, please observe the respective country-specific regulations. E D N E R F T I S E T P L N L P E S K D I F R G U R H Z O K E C N A I L P M O C 571314_0516_A01_TD_XSW1_SP15.indb 5 18.07.2016 14:46:35 XS WIRELESS 1 | 5 FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two condi-
tions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesi-
red operation. This class B digital device complies with the Canadian ICES-003. Changes or modifications made to this equipment not expressly approved by Sennheiser electronic Corp. may void the FCC authorization to operate this equipment. Before putting the device into ope-
ration, please observe the respective country-specific regulations!
Radiofrequency radiation exposure information:
This equipment complies with FCC and IC radiation exposure limits set forth for an uncontrolled en-
vironment. The XSW 1 should be installed and operated with a minimum distance of 20 cm between the radiator and your body. 6 | XS WIRELESS 1 571314_0516_A01_TD_XSW1_SP15.indb 6 18.07.2016 14:46:35