CONTENTS Getting started For camera installation Setting up the system Download the app and set up the system Mounting the camera Select height and location 1. Download the Imilab Home APP from the app store (ios devices) or google play (Android devices). 1. Hang the camera 7-10 ft (2-3m) above the ground. This height maximizes the detection range of the motion sensor of the camera. Mount the camera 3. Firmly screw the base of the mounting bracket onto the wall. 5. Tighten the camera to the mounting bracket and adjust the viewing angle by checking the live stream feed in the app. The camera can be mounted both indoors and outdoors. 1. Drill two holes on the wall by using the base of the IMILAB EC4 as a template. It is recommended that you mark the locations of the hole with a pencil before drilling. The diameter of each hole is approximately 6 mm, and the depth is approximately 30mm. IMILAB EC4 Spotlight Battery Camera User Manual EN DE ES IT FR RU Read this manual carefully before use, and retain it for future reference. English Deutsche Espaol Italiano Franais P 01-14 00-00 00-00 00-00 00-00 00-00 IMILAB EC4 Micro-USB Charging Cable Mounting Bracket Mounting Screws and Anchors Product overview Camera Spotlight Lens Light sensor Motion sensor Microphone Status LED SYNC Button USB Charging Port EN-01 Mounting hole Speaker 2. Sign up for a imilab home account , then follow the onscreen instructions to complete the setup. 4. Match the bottom groove of the camera mounting base with the raised area on the base. Press down until the two surfaces are ush, then turn it in either direction to lock it in place. Camera eld of view t f 0 1
7
) m 3
2
Motion Detection Zone Up to 26 ft (8 m) 2. Insert the anchors into the holes. Warning:
To avoid any damages or injuries, the device must be securely fastened to the Ceiling/wall as specied in the installation instructions. When mounting the security camera on a wall:
Please note that the wall must be able to support at least triple the product's total weight. EN-02 EN-03 EN-04 EN-05 EN-06 Charging the camera Method 1 Reset Power Ethernet USB SYNC Method 2 5V USB Charger Status LED Status Status SYNC Button 2 SYNC Button 15 USB/
3 SYNC Button 8 5 3 PIR 1 PIR PIR Safety statement Specications Name: IMILAB EC4 Model: CMSXJ31A Resolution: 2560x1440 Aperture: F1.6 Power Input: 5 V 2 A Item Dimensions: 82 x 86.8 x 50 mm Operating Temperature: -20 C ~ 50 C FCC ID2APA9-CMSXJ31A Battery (battery pack or batteries) must not be exposed to sunlight, re, or similar overheating conditions. This product is a low power consumption camera with battery built-in. Don't use Real-Time Monitoring feature for long time when charging, in order to avoid battery life loss. Do not use the device in the environment at too high or too low temperature, never expose the device under strong sunshine or too wet enviroment. Precautions The suitable operationg temperature range for this product is between -20~50. Don't use the product in an environment with temperatures above or below the specied range. When charging, the operating tempreture range for this product is between 0C~ 45C. Don't charge the product in an environment with temperatures above or below the specied range. Using the product in a low tempreture environment or charging status will aect its standby time. The actual standby time is related to the user's environment and habbit. To improve the product's performance, please do not place the cameralens facing or next to a reective surface, such as glass windows/doors and white walls, which will cause the image to appear overly bright inareas close to the camera and darker in areas further away, or cause thecamera to produce white images. Please install the product in areas with Wi-Fi reception, and try to place the device where the Wi-Fi signal is strong. In addition, please keep the security camera away from metal structures, microwave ovens, or other locations where signal strength may be impacted. Don't replace the battery in camera yourselfif not properly replaced, there is a danger of explosion. FCC Statement Changes or modications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help. FCC 20cm Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. WEEE Information All products bearing this symbol are waste electrical and electronic equipment (WEEE as in directive 2012/
19/EU) which should not be mixed with unsorted household waste. Instead, you should protect human health and the environment by handing over your waste equi pment to a designated collection point for the recycling of waste electrical and electronic equipment, appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. Please contact the installer or local authorities for more information about the location as well as terms and conditions of such collection points. WEEE Information Hereby, Shanghai Imilab Technology Co., Ltd. declares that the radio equipment type IMILAB EC4 is in compliance with Directive 2014/53/EU. WARNING This product can expose you to chemical Bisphenol A (BPA) which is known to the state of California to cause reproductive. For more information, go www.P65Wamings. ca. gov. Manufacturer: Shanghai Imilab Technology Co., Ltd. Address: Room 001A, Floor 11, Block 1, No. 588 Zixing Road, Minhang District, Shanghai, China For further information, please go to www.imilab.com. Support: help@imilab.com EN-07 EN-08 EN-09 EN-10 EN-11 EN-12 EN-13 EN-14 Pantone Cool Gray 11CC:0 M:20 Y:100 K:0