BioEntry W Compact Outdoor Fingerprint Reader/Controller Installation Guide Version V1.0 www.supremainc.com BioEntry W Important Safety Information Carefully review the information within the user manual before installing/operating the device. Pay careful attention to the warning and cautions below as they are here to prevent any risk/damage to any person(s) or property associated with the device. Warning Caution Failure to heed these warnings may lead to serious injury or even death!
Failure to heed these cautions may lead to minor injury or damage the device. Installation Installation
Do not install the device near heat sources such as radiators,
Do not leave cables (especially power cables) exposed to heat registers, and stoves. heat registers, and stoves. the outer environment. the outer environment.
Do not install the device near areas of large electromagnetic interference.
Do not install the device near objects with a strong magnetic field such as magnets, computer monitors (especially CRT), TV screens and speakers. Usage Usage
Do not disassemble, repair or reconstruct the device.
Do not drop or apply any physical shock/impact to the device. Contact your nearest Suprema dealer for technical support.
Regularly clean the product with a soft dry cloth; avoid
Only use the device its intended use. benzene or alcohol. Copyright 2007 Suprema Inc. 2 BioEntry W Contents About Fingerprint Recognition How to Enroll a Fingerprint on the Device Components Product Description Dimensions Cable Specifications Installation Installation System Configurations Connections Resetting Network Settings Electrical Specifications Product Specifications Troubleshooting Precautions for Device cleaning FCC Rules 4 5 7 9 11 12 13 13 14 17 28 29 30 31 32 33 Copyright 2007 Suprema Inc. 3 BioEntry W About Fingerprint Recognition What is a fingerprint?
Fingerprints are individuals own biometric information and do not change throughout ones life. Fingerprint recognition is a technology that verifies or identifies an individual using such fingerprint information. Free from the risk of theft or loss, fingerprint recognition technology is being widely used in security systems replacing PIN or cards. What is fingerprint recognition?
Fingerprints consist of ridges and valleys. Ridge is a flow of protruding skin in a fingerprint while valley is the hollow between two ridges. Each individual has unique patterns of ridges and valleys; fingerprint recognition makes use of these differences to differentiate between individuals. Fingerprint sensors generate 2-dimentional fingerprint images using various technologies: optical, capacitive, or Fingerprint sensors generate 2-dimentional fingerprint images using various technologies: optical, capacitive, or thermal. Fingerprint template is a collection of numeric data representing the features of a fingerprint. Fingerprint templates are saved inside the memory of BioEntry W, and used for identification. Supremas Personal Information Protection Technology To avoid privacy concern, Supremas fingerprint products do not save fingerprint images itself. It is impossible to reconstruct a fingerprint image from a fingerprint template which is just numeric data of the features of a fingerprint. Copyright 2007 Suprema Inc. 4 BioEntry W How to Enroll a Fingerprint on the Device Suprema's fingerprint products have outstanding recognition performance regardless of the user's fingerprint condition or positioning. However pay careful attention to the following instructions to maximize the performance of the device. Fingerprint Enrollment
It is recommended to enroll the index or middle finger. The thumb, ring or little finger are generally more difficult to position properly. How to place a finger on a sensor How to place a finger on a sensor
Fully cover or provide maximum contact to the surface of the sensor with the desired finger. People tend to place the tip of a finger on the sensor; this will only provide a small area of the finger to be captured and will result in poor performance.
Place the core of the fingerprint near the center of the sensor. This will ensure a good template will be created. The core of a fingerprint is a center where the spiral of ridges is most dense. Copyright 2007 Suprema Inc. 5 BioEntry W How to Enroll a Fingerprint on the Device Fingerprint Enrollment Precautions Operational Warnings
If a finger is wet or too moist, wipe off the moisture then try the scan again.
If a finger is covered with dust or impurities, clean the finger then try the scan again.
If a finger is dry, breathe warm air onto the finger then try the scan again. Solving Authentication Difficulties
Delete then Re-enroll the finger.
Enroll the same finger multiple times.
Enroll the same finger multiple times.
Try a different finger with a more vivid fingerprint.
Enroll various fingers for each user. Copyright 2007 Suprema Inc. 6 BioEntry W Components
Basic Components Wall Mount Screws (2) Main Unit Mounting Screws (2) Wall Mounting bracket (1) Software CD (1) BioEntry W Copyright 2007 Suprema Inc. 7 BioEntry W Components
Optional Accessories Secure I/O 12VDC Power Adaptor Plastic Stand USB Fingerprint Scanner Copyright 2007 Suprema Inc. 8 BioEntry W Product Description
Front LED
Displays the current status with various colors. RFID Scanner
Place an RFID card over the
Place an RFID card over the scanner. Fingerprint Sensor
Place a finger on the surface of the Flicker Blue/Yellow Color per 2sec sensor. LED Green Red Pink Device Status Successful Authentication Failed Authentication Processing Flicker Blue/Sky-Blue Color per 2sec Color per 2sec Standard Operation Standard Operation Flicker Red/Pink Color per 2sec Flicker Blue/Red Color per 2sec Device Locked Discharged Internal Battery Unable to Acquire an IP Address from the DHCP Server. Flicker Red Color per 2sec Unit Malfunction. Contact Your Suprema Dealer/Distributor. Flicker Yellow Color per 2sec Waiting for an Input Flicker Yellow Color per 1sec Requesting IP Address from the DHCP Server. Copyright 2007 Suprema Inc. 9 BioEntry W Product Description
Rear and Bottom Cables
Wiegand Input/Output Cables
Power Cables
RS485 Cables
Ethernet Connector
Input Cables
Relay Cables
Relay Cables LED
Network Status LED Network Reset Switch
See "Resetting Network Settings (page 28)" for more details. Star-shaped screw hole for fixing a body to a metal bracket Copyright 2007 Suprema Inc. 10 BioEntry W Dimensions
BioEntry W
Wall Mounting Bracket 44 mm 50 mm 40 mm 172 mm 172 mm 157 mm Copyright 2007 Suprema Inc. 11 BioEntry W Cable Specifications 3 2 1 PINPINPINPIN 4 5 6 7 SWIN0 SWIN1 ETH TXP Description Description Description Description POWER IN ETH RXN ETH RXP ETH TXN BROWN PURPLE WHITE Color Color ColorColor RED BLACK YELLOW ORANGE 8 9 9 10 11 12 13 14 15 16 17 18 19 20 POWER GND PoE VB2 PoE VB2 PoE VB1 PoE VB1 485 TRXN 485 TRXP 485 GND BLACK BLUE BROWN RED GREEN YELLOW/WHITE STRIPE BLUE/WHITE STRIPE BLACK/WHITE STRIPE WIEGAND GND WHITE/BLACK STRIPE WIEGAND D1 WIEGAND D0 NC RELAY NC RELAY COM RELAY NO WHITE GREEN PINK ORANGE/WHITE STRIPE GREEN/WHITE STRIPE GRAY/WHITE STRIPE Copyright 2007 Suprema Inc. 12 BioEntry W Installation 1. Fix the wall mounting bracket on a wall by 3. Fix the device to the wall mounting bracket using the using wall mounting screws. star-shaped screws. 2. Hook the device on the wall mount bracket. Star-shaped screw screw Wall Mount Screws Copyright 2007 Suprema Inc. 13 BioEntry W System Configurations
Standard Door Sensor Door Lock Door Lock Exit Button Exit Button BioEntry W LAN PC USB Fingerprint Scanner Copyright 2007 Suprema Inc. 14 BioEntry W System Configurations
Secure (Secure I/O) RS485 Door Sensor Door Lock Exit Button BioEntry W Secure I/O LAN PC USB Fingerprint Scanner Copyright 2007 Suprema Inc. 15 BioEntry W System Configurations
Network Door Zone 1 (Anti-passback) RS485 RS485 FaceStation Secure I/O BioEntry W BioEntry W LAN PC Server USB Fingerprint Scanner FaceStation Secure I/O BioEntry W Exit Button RS485 Door Zone 2 (Anti-passback) PC Client PC Client Copyright 2007 Suprema Inc. 16 BioEntry W Connections
Power Connection Recommended Power Specifications UPS
(Optional) DC Power Supply DC Power Supply DC Power Supply DC Power Supply DC Power Supply 12V 10%, at least 500mA. Comply with standard IEC/EN 60950-1. When sharing power with other devices, use a power supply with a higher current rating. Copyright 2007 Suprema Inc. 17 BioEntry W Connections
Ethernet Connection (Connection with HUB) The device can be connected with a regular hub or PoE hub by connecting the Ethernet cable to the Ethernet terminal. PoE(Power over Ethernet) is an Ethernet connection of which the power is supplied from PSE(Power Sourcing Equipment) satisfying the IEEE802.3af standard. Ethernet Hub Copyright 2007 Suprema Inc. 18 BioEntry W Connections
Ethernet Connection (Direct connection with PC) Use a standard CAT-5 cable to connect the device directly to a PC. BioEntry W supports auto MDI/MDIX, therefore a crossover cable is not necessary. Copyright 2007 Suprema Inc. 19 BioEntry W Connections
RS485 Connection for Host Communication GND -
TRX+
TRX-
RS232-485 Converter Power IN (Red) Power GND (Black) Signal GND (Black/White Stripe) TRX+ (Blue/White Stripe) TRX- (Yellow/White Stripe) BioEntry W Power IN (Red) Power GND (Black) Signal GND (Black/White Stripe) TRX+ (Blue/White Stripe) TRX- (Yellow/White Stripe) BioEntry W Only the devices at the both ends of the bus should be terminated. To enable termination on the RS232-485 converter, refer to the converters manual. Adjust the communication speed as needed. The signal quality vary depending on wiring conditions, and it may be necessary to lower the baudrates. The GND signal may be omitted if and only if the GND potential difference is less than 5V. Copyright 2007 Suprema Inc. 20 Notes BioEntry W Connections
RS485 Connection for Secure I/O Power IN (Red) Power GND (Black) Signal GND (Black/ White Stripe) TRX+ (Blue/ White Stripe) TRX- (Yellow/ White Stripe) BioEntry W Power IN (Red) Power GND (Black) Signal GND (Black/White Stripe) TRX+ (Blue/White Stripe) TRX- (Yellow/White Stripe) BioEntry W TRX GND -
TRX+
TRX-
Secure I/O TRX GND -
TRX+
TRX-
Secure I/O For bus termination, only the devices at both ends of the bus should be terminated. Maximum numbers of devices in an RS485 loop are two(2) Suprema devices and four Secure I/Os. Copyright 2007 Suprema Inc. 21 Notes BioEntry W Connections
Relay Connection Fail safe lock Deadbolt /
Door strike
DC Power supply BioEntry W
(20) Relay NO (Gray/White Stripe)
(19) Relay COM (Green/White Stripe)
(18) Relay NC (Orange/White Stripe) Copyright 2007 Suprema Inc. 22 BioEntry W Connections
Relay Connection Fail secure lock Deadbolt /
Door strike
DC Power supply BioEntry W
(20) Relay NO (Gray/White Stripe)
(19) Relay COM (Green/White Stripe)
(18) Relay NC (Orange/White Stripe) Copyright 2007 Suprema Inc. 23 BioEntry W Connections
Relay Connection - Automatic door RTE Switch Presence Detector Automatic Door RTE Switch BioEntry W
(20) Relay NO (Gray/White Stripe)
(19) Relay COM (Green/White Stripe)
(18) Relay NC (Orange/White Stripe) Copyright 2007 Suprema Inc. 24 BioEntry W Connections
Digital Input Connection (RTE/ Door sensor) Door Status Request TO Exit BioEntry W
(13) 485 GND (Black/White Stripe)
(13) 485 GND (Black/White Stripe)
(1) Input 1 (Brown)
(13) 485 GND (Black/White Stripe)
(2) Input 0 (Purple) Copyright 2007 Suprema Inc. 25 BioEntry W Connections
Digital Input Connection (Alarm/ Emergency switch) Switch #1 Switch #2 BioEntry W
(13) 485 GND (Black/White Stripe)
(13) 485 GND (Black/White Stripe)
(1) Input 1 (Brown)
(13) 485 GND (Black/White Stripe)
(2) Input 0 (Purple) Copyright 2007 Suprema Inc. 26 BioEntry W Connections
Wiegand Input RFID Reader GND Wiegand D1 Wiegand D0
Wiegand Output Controller GND Wiegand D1 Wiegand D0 BioEntry W
(14) Wiegand GND (White/Black Stripe)
(15) Wiegand D1 (White)
(16) Wiegand D0 (Green) BioEntry W
(14) Wiegand GND (White/Black Stripe)
(15) Wiegand D1 (White)
(16) Wiegand D0 (Green) Copyright 2007 Suprema Inc. 27 BioEntry W Resetting Network Settings In case of forgetting network setting of the device (TCP/IP or RS-485 setting) during installation or using the device, you can initialize network setting (TCP/IP or RS-485 setting) by using the network reset switch on the back panel of the device. Please refer to the figures as below. 1. Turn on the device. 2. Press and hold the network reset switch until the device turns off. (Then, the device will restart.) Network Default Setting
TCP/IP Address : 192.168.0.1
Not checked Use Server
RS-485 : PC Connection, 115200bps 3. Modify then save the TCP/IP or RS485 settings. 4. Reboot the device. 5. Confirm the new settings. Network Reset Switch Copyright 2007 Suprema Inc. 28 BioEntry W Electrical Specifications Min. Typ. Max. Notes Voltage (V) 10.8 12 13.2 Use regulated DC power adaptor only. Power Switch Input TTL/
Wiegand Output Current (mA) VIH (V) VIL (V) Pull-up resistance () VOH (V) VOL (V) Pull-up resistance () Switching capacity (A) Relay Switching power
(resistive) Switching voltage (V)
250
1 0.3 30W 37.5VA 110 125 TBD TBD 4.7k 5 0.8 4.7k
The input ports are pulled up with 4.7k resistors. The outputs ports are open drain type, pulled up with 4.7k resistors internally. 30V DC 125V AC DC AC DC AC Copyright 2007 Suprema Inc. 29 BioEntry W Product Specifications System Max Users 5000 users (10,000 templates) [1:1 & 1:N]
Log Capacity 50,000 logs CPU 533MHz DSP Memory 8MB Flash + 8MB RAM RF Options 125KHz HID PROX Interfaces Interfaces TCP/IP, RS485, Wiegand TCP/IP, RS485, Wiegand Input / Output 2 TTL Inputs, 1 Relay Output Power 12VDC, PoE (Power over Ethernet) General Dimensions BioEntry W
(W x H x D) Wall Bracket
(W x H) 50 x 172 x 44 mm 40 x 157 mm (screw joint included) Copyright 2007 Suprema Inc. 30 BioEntry W Troubleshooting Please contact your local dealer/distributor for support or contact Suprema at support@supremainc.com. Please submit the following information and we will coordinate support with your local dealer/distributor.
Device model
F/W version of the device
H/W version of the device
Detailed information regarding the issue
Error messages / screenshots, if possible
Contact information (Company, Name, Telephone, Email)
Contact information (Company, Name, Telephone, Email) Copyright 2007 Suprema Inc. 31 BioEntry W Precautions for Device Cleaning
Wipe out the device surface with dry towel or cloth.
Use a soft dry towel when removing dust or impurities from the surface of the sensor. Cleaning the sensor with a detergent, benzene or thinner will damage the surface and disrupt the unit's ability to properly read a fingerprint. Copyright 2007 Suprema Inc. 32 BioEntry W FCC Rules
Caution Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the users authority to operate the equipment.
Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interface, and (2) this device must accept any interface received, including interference that may cause undesired operation.
Information to User Information to User This equipment has been tested and found to comply with the limit of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, user and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation; if this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more the following measures:
1. Reorient / Relocate the receiving antenna. 2. Increase the separation between the equipment and receiver. 3. Connect the equipment into an outlet on a circuit difference from that to which the receiver is connected. 4. Consult the dealer or an experienced radio/TV technician for help. Copyright 2007 Suprema Inc. 33 16 Tel : 031-783-4510 Tel : 031-783-4510 Fax : 031-783-4503
: sales@suprema.co.kr
: www.suprema.co.kr
: www.biostation.co.kr BioEntry Plus