Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection LAN Connection RS485 Connection Relay Connection Digital Input Connection WiegandInput/Output Output Installation of Wall-mount Bracket Installation Reference Specification Electrical Specification FCC Rules Safety precautions Do not install the device in a place subject to direct sun light, humidity, dust or soot. Do not place the device next to heating equipments. Do not place a magnet near the product. It may cause a damage or a failure to the product. Be careful not to let liquid like water, drinks or chemicals leak inside the device. It may cause a failure. In cleaning, do not splash water on the device but wipe it out with smooth cloth or towel. Clean the device often to remove dust on it. The list below is to keep users safety and prevent any loss. Please read safety precautions carefully before use. Safety precautions Do not drop the device. Do not let children touch the devicewithout supervision. Do not disassemble, repair or alter the device. The warranty does net apply to any product damage cause by an arbitrary installation or repair. Do not use the device for any other purpose than specified. Do not damage the device. Contact your nearest dealer in case of a trouble or problem. The list above is to keep users safety and prevent any loss. Please read safety precautions carefully before use. Productcomponents Basic components Xpass bracket Extended Ethernet Cable Wall mounting screws
(2 ea) Knife Blocks
(2 ea) Shrinkable Tubes Software CD The components shown above may differ depending on the installation environment. Optional accessories Secure I/O Plastic stand Extended bracket adaptor Names of each parts LED status Product Dimension
(unit : mm)
< Front View >
< Side View >
< Bracket >
< Extended bracket >
Cables and Connectors No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Pin Name 485 GND Wiegand-GND 485 -
Wiegand-1 485 +
Wiegand-0 Input-1 Relay Open Input-GND Relay Com Input-0 Relay Close TX+ (LAN) Power IN+
TX-(LAN) Power IN-
RX+ (LAN) Power OUT+
RX-(LAN) Power OUT-
VB1 VB2 VB1 VB2 Color White (black string) Black Yellow (black string) White Blue (white string) Green Brown Gray (white string) Gray Green (white string) Purple Orange (black string) Pink Red Orange Black (white string) Blue Light Blue Yellow Black (white string) black string) Brown (white string) black string) Brown (white string) Cables and Connectors Cable Specification Pin Relay Wiegand Switch 485 Pin Name RLY NC RLY COM RLY NO WGD D0 WGD D1 WGD GND IN 0 IN 1 IN GND 485+
485-
485 GND Color Orange (black string) Green (white string) Gray (white string) Green White Black Purple Brown Gray Blue (white string) Yellow (black string) White (black string) Pin Power Pin Name POWER OUT -
POWER OUT +
POWER IN -
POWER IN +
Black (white string) Light Blue Black (white string) Red 1 2 3 4 5 6 7 8 9 10 11 12 3 1 LAN cable Pin Pin Name 1 2 3 4 5 6 7 8 LAN RX-
RX+
TX-
TX+
VB1 VB1 VB2 VB2 Color Yellow Blue Orange Pink black string) black string) Brown (white string) Brown (white string) Ethernet extension cable Modular Jack (A) Connector (B) Pin Name TX+
TX-
RX+
RX-
VB1 VB1 VB2 VB2 Color Blue Orange Black Yellow Red Green Brown Gray Power Connection 1 Pin 14 16 Pin Name POWER IN+
POWER IN-
Color Red Black (white string) Recommended power supply 12V 10%, at least 500mA. Comply with standard IEC/EN 60950-1. To share the power with other devices, use a power supply with higher current ratings. Power Connection 2 Recommended power supply Please use the distance of LAN cable within 100m in case of POE power. LAN Connection LAN Connection (Direct connection with PC) RS485 Connection for Host Communication Pin 1 3 5 Pin Name 485 GND 485 -
485 +
Color White (black string) Yellow (black string) Blue (white string) RS485 Connection for Secure I/O Pin 1 3 5 Pin Name 485 GND 485 -
485 +
Color White (black string) Yellow (black string) Blue (white string) Max number of devices Maximum eight(8) devices (including Master) interworksin an RS485 loop. Relay Connection Fail safe lock Pin 10 12 Pin Name RLY COM RLY NC Color Green (white string) Orange (black string) Relay Connection Fail secure lock Pin 8 10 Pin Name RLY NO RLY COM Color Gray (white string) Green (white string) Relay Connection -Automatic door Pin 8 10 Pin Name RLY NO RLY COM Color Gray (white string) Green (white string) Digital Input Connection (Alarm, Emergency S/W) Pin 7 9 11 Pin Name IN 1 IN GND IN 0 Color Brown Gray Purple Digital Input Connection (RTE, Door sensor) Pin 7 9 11 Pin Name IN 1 IN GND IN 0 Color Brown Gray Purple WiegandInput/Output WiegandInput WiegandOutput Pin 2 4 6 Pin 2 4 6 Pin Name WGD GND WGD D1 WGD D0 Pin Name WGD GND WGD D1 WGD D0 Color Black White Green Color Black White Green Output Pin 10 12 18 20 Pin Name RLY COM RLY NC PWR OUT +
PWR OUT -
Color Green (white string) Orange (black string) Light Blue Black (white string) Caution : Max. 700mA is supplied using adapter for the external output. Be careful to satisfy the power capacity in use. Installation of Wall-mount Bracket Fix wall mount bracket on a wall using wall mounting screws Hook Xpasson the wall mount bracket Fix Xpassand wall mounting bracket using a wall mounting screw. Installation Reference 1 -Stand alone Installation Reference 2 Standalone (Secure) Installation Reference 3 Network Specification CPU Memory RF Card User Capacity Log Capacity Network interfaces IP Rate Sound LED RTC I/O Power Operating Temperature Size Certificates 32 bit Micro-processor 8MB FLASH + 16MB SDRAM 13.56 MHz Mifare(XPM) 125 KHz EM Prox(XPE) 125 KHz HID Prox(XPH) 40000 user 50000 log TCP/IP, RS485 IP 65 class Multi-tone buzzer Multi-color LED Lithium-ion rechargeable batteries Relay x 1 Tamper x 1 Switch input x 2 Wiegandx 1 12Vdc, POE
-20 ~ 50 C 45 x 130 x 27mm (W x H x D ) CE, FCC, KCC, IP65 Caution for RTC Battery It may be occurred the risk of explosionfor improper replacement of battery. Please use the specified battery according to proper instruction. Electrical Specification Typ. Min. Max. Notes Power Voltage (V) Current (mA) Switch Input VIH (V) VIL (V) Pull-up resistance (
TTL/WiegandOutput VOH (V) VOL (V)
) Pull-up resistance (
) Relay Switching capacity (A) Switching power
(resistive) Switching voltage (V) 10.8 12
-
-
-
-
-
-
-
-
-
-
TBD TBD 4.7k 5 0.8 4.7k
-
-
-
13.2 140
-
-
-
-
-
Use regulated DC power adaptor only The input ports are pulled up with 4.7k resistors The outputs ports are open drain type, pulled up with 4.7k resistors internally 1 0.3 30W 37.5V A 110 125 30V DC 125V AC DC AC DC AC FCC Rules Caution Warning Information to User Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the users authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation issubject to the following two conditions: (1) This device may not cause harmful interface, and
(2) this device must accept any interface received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limit of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference ina residential installation. This equipment generates, user and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation; if this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference byone or more the following measures:
1. Reorient / Relocate the receiving antenna. 2. Increase the separation between the equipment and receiver. 3. Connect the equipment into an outlet on a circuit difference from that to which the receiver is connected. 4. Consult the dealer or an experienced radio/TV technician for help