Installation Guide Wireless N Gigabit Access Point EAP120 / EAP220 CONTENTS Network Topology Requirements 01 Overview 02 Hardware Installation 04 1. Installation Requirements ....................................................... 04 2. Mounting Bracket ................................................................... 04 3. Installation ............................................................................ 05 4. Powering Mode ...................................................................... 09 Getting Started with the EAP 11 Q&A 14 Specifications 15 Technical Support 16 About This Installation Guide This guide is designed to familiarize you with the general layout of the EAP, describe how to deploy the device in your network and how to configure the device. Your EAP has more features and functionalities which can be found in the User Guide. Network Topology Requirements Typical topology for the EAP is described below. Enwuvgt Master EAP Slave EAP Slave EAP Internet Router Switch Typical Topology The EAP120 and EAP220 provide two management modes: Cluster and Standalone. By defaultthe management mode is Cluster. In this mode, all the EAPs in the same LAN will form a Cluster, and a Master EAP will be elected among them to manage the other EAPs, called Slave EAPs. A DHCP server is required in the local network to assign IP addresses to the EAPs. A router usually acts as the DHCP server. Typically, a PoE switch can be used to provide Power over Ethernet for each EAP. Or, each EAP must be powered with a power adapter individually. 01 Overview LED Explanation LED Status Quickly flashing green Solid green Slowly flashing red System LED Top View of the EAP Indication System initialization is complete. The device is working properly. The system is abnormal. RAM, Flash, Ethernet, WLAN or firmware may be malfunctioning. Firmware is being updated. Quickly flashing yellow Alternating red/green/yellow twice The device is being reset. Interface Panel RESET CONSOLE ETHERNET ON/OFF POWER ARROW 1 Interface Panel of the EAP The interface panel components of the EAP, from left to right, are described in the following list:
Kensington Security Slot Secure the lock into the slot to prevent the device from being stolen. 02 RESET With the device powered on, press and hold the RESET button for about 8 seconds, and then release the button. The device will restore to factory default settings. CONSOLE This port is used to connect with the serial port of a computer or a terminal to check and monitor simple system information of the device. ETHERNET This port is for connection to a router or switch to transmit and receive data as well as to a PSE device for power supply. Power sourcing equipment (PSE) is a device such as a switch that provides power over Ethernet cables to linked devices. ON/OFF Press this button to power on/off the device. Please remember to press it to use the device. POWER The power jack is for connection to the power adapter. Please use the power adapter provided. Refer to Powering Mode to learn how to power the device via PoE and power adapter. ARROW 1 To align with ARROW 2 in the mounting bracket before the EAP locks into place. Please refer to Mounting Bracket to locate ARROW 2. 03 Hardware Installation The EAP can be wall or ceiling mounted and can be powered via a PSE device or the provided adapter. Please suitably arrange your wire layout before the mounting. 1. Installation Requirements Check and prepare the following items in the package for installation. One EAP One Mounting Bracket One Installation Guide Three Nuts/ Washers/ Plastic Extending Tubes/ Self-tapping Screws/ Pan Head Screws Besides the above installation kits, these tools may be needed for hardware installation: pencil, ruler, drill, hammer, screwdriver and ladder. 2. Mounting Bracket The following figure describes the structure of the mounting bracket. ARROW 2, to align with ARROW 1 under the interface panel Ceiling mounting slot Wall mounting slot Locking clip Mounting Bracket 04 3. Installation Ceiling Mounting Note:
Make sure the thickness of the ceiling is less than 18mm and the ceiling can bear at least five kilograms. If the ceiling is made of low-strength material like gypsum, it is not recommended to mount the EAP on the ceiling. If it has to do, add a layer of strong material under the nut to ensure the EAP is mounted solidly. 1. Remove the ceiling tile. Remove the Ceiling Tile 2. Place the mounting bracket at the center of the ceiling tile. Mark the positions of three mounting slots and the hole for Ethernet cable to feed through. L L40mm Mark of the Hole for Ethernet cable to feed through Mark the Positions 05 3. Use a drill bit to drill three holes for screws, and drill a 10mm hole for the Ethernet cable to feed through. 4mm hole for mounting bracket 10mm hole for Ethernet cable feed Drill the Holes 4. Secure the mounting bracket to the ceiling board with nuts, washers and pan head screws as shown below. Nut Washer Hole to feed the Ethernet cable Hole to feed the screw Pan head screw Secure the Mounting Bracket 06 5. Align ARROW 1 with ARROW 2 as shown below, then press the EAP into the mounting bracket. R E S E T C O N S O L E E T H E R N E T O N
/
O F F P O W E R 6. Turn the EAP clockwise until it locks into place. Align Two Arrows Make the EAP Lock into Place 07 7. Feed the cable through the hole and set the ceiling tile back into place. 8. Connect the Ethernet cable to the Ethernet port and ceiling mounting is done. Fix the Ceiling Tile Wall Mounting There are two wall-mounting slots at the bottom of the EAP. To mount the EAP on a wall, please follow the steps below. 1. Make two small pencil marks on the wall. The distance between the two marks should be 98.6mm. Wall L L=98.6mm Mark on the Wall 08 2. Use a drill bit to drill two holes through the center of your marks. The diameter of both holes should be 4mm. Wall 4mm in diameter Drill Two Holes 3. Insert the plastic extending tubes into the 4mm holes and drive the screws into the tubes. 4. As Ceiling Mounting shows, press the EAP into the mounting bracket and turn it clockwise until it locks into place. 5. Simply hang your EAP and the wall mounting is done. 4. Powering Mode The EAP can be powered via a PSE device (e.g., a PoE switch) or a power adapter. Via PSE Device EAP220 TL-SG3424P 2 1 Power the EAP via a PoE 09 1. Connect the EAP to a PSE device through an Ethernet cable. 2. Press the ON/OFF button on the interface panel of the EAP. Via Power Adapter Socket TL-SG2008 EAP220 Socket Power the EAP via a Power Adapter 1. Plug one end of the provided power adapter into the power jack of the EAP, and the other end to a standard electrical wall socket. 2. Press the ON/OFF button on the interface panel of the EAP. 10 Getting Started with the EAP How do you quickly build a wireless network with several EAPs? The following content will instruct you on how to do network connection and software configurations on EAPs. Management host can be connected to the EAPs wirelessly or with wires. Wireless Login is recommended conveniently. Option 1: Wireless Login Internet Router Switch Master EAP Slave EAP Slave EAP Cluster Management Host Sample Network Diagram for Wireless Login Step 1: Power on Power on the EAPs. The EAP with system initialization first completed will be elected as the Master. 11 Step 2: Wireless Access 1. Make sure the management host is set to obtain IP address automatically. 2. Join the wireless network. The default SSID and password are shown below. SSID: TP-LINK_2.4GHz_XXXXXX or TP-LINK_5GHz_XXXXXX for EAP220; TP-
LINK_2.4GHz_XXXXXX for EAP120. XXXXXX is the last 6 characters of EAP's MAC address. Password: Password is empty. Step 3: Quick Setup 1. Open a web browser and type in http://tplinkeap.net to log in to the EAP. The default user name and password are admin. In the Cluster mode, the login will be directed to the Master EAP. 2. Create a new user name and password. 3. Follow instructions step by step to complete Quick Setup. Congratulations! The above configurations on the Master EAP will be synchronized to all the other EAPs automatically. Now you can enjoy the wireless network. If you want to perform more configurations, please connect to the new SSID. Option 2: Wired Login Internet Router Switch Management Host Master EAP Slave EAP Slave EAP Cluster Sample Network Diagram for Wired Login 12 Step 1: Power on Power on the EAPs. The EAP with system initialization first completed will be elected as the Master. Step 2: Wired Access 1. Make sure the management host is set to obtain IP address automatically. 2. Access your DHCP server and locate the IP address of the EAPs. Step 3: Quick Setup 1. Open a web browser, in the address field type in any IP address of the EAPs to log in the web server. The default user name and password are admin. In the Cluster mode, the login will be directed to the Master EAP. 2. Create a new user name and password. 3. Follow instructions step by step to complete Quick Setup. Congratulations! The above configurations on the Master EAP will be synchronized to all the other EAPs automatically. Now you can enjoy the wireless network. 13 Q&A Q1. Can Master EAP work as an access point?
Yes. In additon to managing and monitoring Slave EAPs, the Master EAP is equipped with the features and functions of an AP, providing wireless access to clients. Q2. What is the maximum number of EAPs in a Cluster?
The maximum number of EAPs in a cluster is 24. Q3. Can EAP120 be in the same Cluster with EAP220?
No, EAP120 and EAP220 cannot be in the same cluster. Only the EAPs of the same model can be clustered together. 14 Specifications Models HARDWARE FEATURES Interface Buttons Power Supply PoE Compatible Maximum Power Consumption Antenna Mounting Certification Operating Temperature Operating Humidity WIRELESS FEATURES Wireless Frequency Wi-Fi Standard Maximum Data Rate Max RF Transmission Power(1) Multiple SSIDs Captive Portal Authentication Wireless Security Cluster EAP120 EAP220 10/100/1000Mbps Ethernet port (RJ-45) Console port (RJ-45) Power connector (DC-2) Kensington lock slot RESET ON/OFF (for power supply) PoE or External 12VDC /
1A Power Supply 802.3af 4.4W 2*4dBi Embedded Ceiling/Wall mounting (Kits included) CE FCC RoHS 0~40 (32~104) 10%~90% non-condensing PoE or External 12VDC /
1.5A Power Supply 802.3af 9.6W 4*4dBi Embedded 2.4GHz IEEE 802.11b/g/n Up to 300Mbps 23dBm 2.4GHz & 5GHz IEEE 802.11a/b/g/n Up to 600Mbps 2.4GHz:23dBm 5GHz:20dBm Up to eight per radio Support WEP WPA/WPA2-personal WPA/WPA2-enterprise Support, up to 24 APs in a cluster Maximum transmission power may vary in different countries or regions. 15 Technical Support For more help, please go to: http://www.tp-link.com/en/support/faq To download the latest firmware, driver, utility and user guide, please go to:
http://www.tp-link.com/en/support/download For all other technical support, please contact us by using the following details:
Global Tel: +86 755 2650 4400 Fee: Depending on rate of different carriers, IDD. E-mail: support@tp-link.com Service time: 24hrs, 7 days a week Australia/New Zealand Tel: AU 1300 87 5465 (Depending on 1300 policy.) NZ 0800 87 5465 (Toll Free) E-mail: support.au@tp-link.com (Australia) support.nz@tp-link.com (New Zealand) Service time: 24hrs, 7 days a week Brazil France Germany/Austria Indonesia Italy Malaysia Poland Toll Free: 0800 608 9799 (Portuguese Service) E-mail: suporte.br@tp-link.com Service time: Monday to Saturday, 09:00 to 20:00; Saturday, 09:00 to 15:00 Tel: 0820 800 860 (French service) Fee: 0.118 EUR/min from France Email: support.fr@tp-link.com Service time: Monday to Friday 9:00 to 18:00 *Except French Bank holidays Tel: +49 1805 875 465 (German Service)
+49 1805 TPLINK
+49 820 820 360 Fee: Landline from Germany: 0.14EUR/min. Landline from Austria: 0.20EUR/min. E-mail: support.de@tp-link.com Service time: Monday to Friday, 9:00 to 12:30 and 13:30 to 17:30. GMT+ 1 or GMT+ 2 (DST in Germany) *Except bank holidays in Hesse Tel: (+62) 021 6386 1936 Fee: Depending on rate of different carriers. E-mail: support.id@tp-link.com Service time: Monday to Friday 9:00 to 18:00 *Except public holidays Tel: +39 023 051 9020 Fee: Depending on rate of different carriers. E-mail: support.it@tp-link.com Service time: Monday to Friday, 9:00 to13:00 and 14:00 to 18:00 Toll Free: 1300 88 875 465 Email: support.my@tp-link.com Service time: 24hrs, 7 days a week Tel: +48 (0) 801 080 618
+48 223 606 363 (if calls from mobile phone) Fee: Depending on rate of different carriers. E-mail: support.pl@tp-link.com Service time: Monday to Friday 9:00 to 17:00. GMT+1 or GMT+2 (DST) 16 Russian Federation Singapore Switzerland Turkey UK Ukraine USA/Canada Tel: 8 (499) 754 5560 (Moscow NO.) 8 (800) 250 5560 (Toll-free within RF) E-mail: support.ru@tp-link.com Service time: From 09:00 to 21:00 (Moscow time)
*Except weekends and holidays in RF Tel: +65 6284 0493 Fee: Depending on rate of different carriers. E-mail: support.sg@tp-link.com Service time: 24hrs, 7 days a week Tel: +41 (0) 848 800 998 (German Service) Fee: 4-8 Rp/min, depending on rate of different time. E-mail: support.ch@tp-link.com Service time: Monday to Friday, 9:00 to 12:30 and 13:30 to 17:30. GMT+ 1 or GMT+ 2 (DST) Tel: 0850 7244 488 (Turkish Service) Fee: Depending on rate of different carriers. E-mail: support.tr@tp-link.com Service time: 9:00 to 21:00, 7 days a week Tel: +44 (0) 845 147 0017 Fee: Landline: 1p-10.5p/min, depending on the time of day. Mobile: 15p-40p/min, depending on your mobile network. E-mail: support.uk@tp-link.com Service time: 24hrs, 7 days a week Tel: 0800 505 508 Fee: Free for Landline; Mobile: Depending on rate of different carriers. E-mail: support.ua@tp-link.com Service time: Monday to Friday 10:00 to 22:00 Toll Free: +1 866 225 8139 E-mail: support.usa@tp-link.com Service time: 24hrs, 7 days a week 17 FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC RF Radiation Exposure Statement:
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. To comply with FCC RF exposure compliance requirements, this grant is applicable to only Mobile Configurations. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. CE Mark Warning or This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. IC Statement This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe A est conforme la norme NMB-003 du Canada.
,
. 18 Safety Information 1) When product has power button, the power button is one of the way to shut off the product; When there is no power button, the only way to completely shut off power is to disconnect the product or the power adapter from the power source. 2) Dont disassemble the product, or make repairs yourself. You run the risk of electric shock and voiding the limited warranty. If you need service, please contact us. 3) Avoid water and wet locations. NCC Notice & BSMI Notice This product can be used in the following countries:
AT / BG / BY / CA / CZ / DE / DK / EE / ES / FI / FR / GB / GR / HU / IE / IT LT / LV / MT / NL / NO / PL / PT / RO / RU / SE / SK / TR / UA / US 19 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks of their respective holders. No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from TP-LINK TECHNOLOGIES CO., LTD. Copyright 2014 TP-LINK TECHNOLOGIES CO., LTD. All rights reserved. Website: http://www.tp-link.com Tel: +86 755 26504400 E-mail: support@tp-link.com 7106505003 REV1.0.1