iNet Box Operating Instructions To be kept in the vehicle!
Page 2 iNet Box Table of Contents Symbols used Symbols used ........................................................................ 2 Intended use ....................................................................... 2 Note containing information and tips. Operating Instructions Intended use The iNet Box was developed for controlling TIN-bus-capable Truma devices via mobile terminal devices (e.g. smartphones, tablet PCs). Communication is via Bluetooth or GSM. Safety instructions ............................................................. 3 Display and control panels / connections ...................... 3 Preparing start-up .............................................................. 4 Install the Truma app on mobile terminal device .................. 4 Device identification .............................................................. 4 Bluetooth communication ................................................ 4 Bluetooth connection set-up ................................................. 4 Bluetooth bonding ................................................................. 5 GSM communication ......................................................... 5 Preparing iNet Box ................................................................ 5 Setting up the GSM connection ............................................ 5 Operation ............................................................................ 6 Technical data ..................................................................... 6 Troubleshooting guide ...................................................... 6 Factory setting .................................................................... 6 Cleaning ............................................................................... 6 Maintenance ...................................................................... 7 Disposal ............................................................................... 7 Accessories ......................................................................... 7 Declaration of conformity ................................................. 7 Warranty declaration ......................................................... 8 2 Operating Instructions Safety instructions iNet Box must not be operated unless it is in technically per-
fect condition. Repairs must be carried out immediately. Only carry out repairs yourself if the solution is described in the trouble-
shooting guide of this manual. A defective iNet Box may only be repaired by the manufac-
turer or the manufacturers service department. Display and control panels / connections Display panels M S G R E W O P H T O O T E U L B iNet Box Do not perform any modifications to the iNet Box as this can be dangerous. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Figure 1 Top view LED Blue Green Red Description Bluetooth flashes for Bluetooth pairing with 1Hz Power lights up when ready for operation GMS lights up when GSM operation is not possible This device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Control panels / connections 1 2 43 M S I T N T I X M E S G Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
(1) lappareil ne doit pas produire de brouillage, et
(2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est suscepti-
ble den compromettre le fonctionnement. Figure 2 Rear view Description Item Bluetooth / factory setting button 1 2 Insert, Mini-SIM card (25 x 15 mm) External antenna connection GSM (SMA) 3 4 Changeover switch, internal / external antenna 3 Preparing start-up 5. Switch on all devices connected to the iNet Box (see Bluetooth connection set-up on Page 4). Install the Truma app on mobile terminal device 1. Load the Truma app (at www.truma.com) onto the mobile terminal device. 2. Install the Truma app on the mobile terminal device. If necessary, an installed Truma app must be updated. 3. Repeat steps 1 and 2 for additional mobile terminal devices. 4. To continue installation, start the Set-up assistant of the Truma app or follow the instructions below. Device identification Bluetooth communication Bluetooth connection set-up To connect the mobile terminal device to the iNet Box, the mobile terminal device must be switched on and Bluetooth must be activated (see the operating instructions of the mo-
bile terminal device). Press the button (Figure 2 1) for approximately 1 second. If the Bluetooth pairing is active, the iNet Box becomes visible for 3minutes and the blue LED (Figure 1) flashes at the same time at a frequency of 1 Hz. The name iNet Box appears on the mobile terminal device. The TIN-bus-capable Truma devices connected to the iNet Box and CP plus must be known to the CP plus. The Bluetooth connection to the mobile terminal device can be made. 1. Connect all TIN-bus-capable Truma devices to the CP plus and the iNet Box. 2. Switch on the power supply for the devices connected to the CPplus and iNet Box (including iNet Box). 3. Perform the device search on the CP plus (see CP plus oper-
ating instructions, Initial start-up). After a repair / retrofitting, the device search with CPplus must be repeated. 4. At least the Bluetooth communication must be set up for each mobile terminal device. Up to 20 mobile terminal devices can be logged on /
saved on the Bluetooth connection. Four mobile terminal devices can control the iNet Box at the same time. The first mobile terminal device set up (administrator) remains permanently in the iNet Box memory. The 21st mobile ter-
minal device overwrites the second one in the memory. This means that each new mobile terminal device logged on over-
writes the oldest one in the memory. The first mobile terminal device set up (administrator) can only be deleted by restoring to the factory setting
(see Factory setting on page 6on Page 6) in the iNet Box. 4 Bluetooth bonding If there is a saved mobile terminal device within range of the iNet Box, a Bluetooth bonding to the iNet Box is automatically performed. GSM communication Preparing iNet Box A Bluetooth connection must first be established before the GSM communication can be set up and operated. A Mini-SIM card with its own call number and sufficient credit is required for GSM communication. The Mini-SIM card is not included in the scope of delivery. Insert the Mini-SIM card Position the Mini-SIM card (25 x 15 mm) so that the missing corner faces the slot and the contact surface faces the bottom of the iNet Box. Push the Mini-SIM card into the SIM slot until it engages. Removing the Mini-SIM card Pressing the Mini-SIM card again enables it to be removed. Setting up the GSM connection An active Bluetooth connection is required for the continued installation and the Truma app on the mobile terminal device must be started. 1. Select the set-up assistant of the Truma app 2. Via the set-up assistant, enter the PIN and the call num-
ber of the Mini-SIM (iNet Box), and also a freely selectable name (maximum 11 characters). Notes:
The Mini-SIM card is blocked after 3 incorrect PIN entries. To unblock, the Mini-SIM card must be removed from the iNet Box and unblocked in the mobile terminal device with the PUK. If the Mini-SIM card is replaced, the GSM connection must be set up again before using the GSM communication. M S I
-
i n M i M S I T N T I X M E S G Figure 3 5 Operation Troubleshooting guide To operate the devices connected via the iNet Box, follow the steps in the Truma app. The last incoming command is executed. Bluetooth communication has priority over GSM communication. The iNet Box automatically switches from GSM to Bluetooth communication as soon as a saved mobile terminal device comes into reception range. It automatically switches back to GSM communication when the device goes out of reception range. Technical data 147 x 96 x 40 mm Dimensions (L x W x H) Operating conditions Temperature Humidity Air pressure Storage temperature range -30C to +70C Interface Power supply Power consumption Standby current Weight TIN bus 9V 29V xxx mA xxx mA approx. 500g
-30C to +60C 10%rH to 99%rH 942 hPa to 1061 hPa External GSM antenna Anntenna gain max. 5.5 dBi at 850 MHz and max. 2 dBi at 1900 MHz Subject to technical changes. 6 The green Power LED (ready for operation) does not light up. Check the operating voltage. LED red GSM error No GSM reception No Mini-SIM card Mini-SIM card blocked Modem error Progress bar stops during firmware update
/ Bluetooth connection interrupted for an extended time / pre-
vious firmware status remains. Factory setting Reset all settings to the factory setting and delete all individual data. Press the button (Figure 2 1) for at least 20 seconds. The blue LED flashes briefly to indicate that resetting has been done. Cleaning Clean only with a moist, lint-free cloth. Make sure that no liq-
uid gets inside the iNet Box. This can cause a short circuit and destruction of the iNet Box. Maintenance There are no components inside the iNet Box that re-
quire servicing by the customer. If it is faulty, replace the complete iNet Box. Firmware update An iNet Box firmware update is indicated in the Truma app on the mobile terminal device. Transmission is via Bluetooth (fol-
low the instructions in the Truma app). Disposal The device must be disposed of in accordance with the ad-
ministrative regulations of the respective country in which it is used. National regulations and laws (in Germany, for example, the End-of-life Vehicle Regulation) must be observed. Accessories External GSM antenna TIN-bus cable, 3 different lengths Declaration of conformity 1. Information about the manufacturer Name:
Address: Wernher-von-Braun-Str. 12, D-85640 Putzbrunn Truma Gertetechnik GmbH & Co. KG 2. Device identification Type / model:
GSM control unit / iNet Box 3. Complies with the requirements of the following ECdirectives 3.1 Electromagnetic compatibility 2004/108/EC 3.2 Radio interference suppression of motor vehicles UN ECE R10 3.3 End-of-life vehicle directive 2000/53/EC 3.4 Low Voltage Directive 2006/95/EC and bears the CE mark and the type approval number E1 xxxxxxxxxxxxx 4. Basis of the proof of conformity 6. Signatory details Signature: xxxxx xxxxxxxx Putzbrunn, 17.11.2014 7 Warranty declaration 8 9 Las instrucciones de uso y de montaje en su idioma pueden solicitarse al fabricante Truma o al Servicio postventa Truma en su pas. Saat kytt- ja asennusohjeen pyynnst omalla kielellsi valmistajalta (Truma) tai maasi Truma-huoltoon. Spr om bruks- og monteringsanvisning p norsk hos produsenten Truma eller Trumas serviceavdeling i landet ditt. Truma Truma . Nvod k pouit a montn nvod si lze v ei Va zem vydat u vrobce Truma nebo servisu Truma ve Va zemi. Nvod na pouitie a mont vo Vaom ttnom jazyku si mete vyiada u vrobcu Truma alebo v servise Truma vo Vaej krajine. As instrues de utilizao e montagem podem ser solicitadas junto do fabricante Truma ou do servio de assistncia da Truma no seu pas. Az n nyelvn a hasznlati s beszerelsi utasts a Truma gyrtjtl vagy az adott orszg Truma szerviztl szerezhet be. Instrukcj obsugi i instrukcj montau w Pastwa wersji jzykowej mona otrzyma w firmie Truma lub serwisie firmy Truma znajdujcym si w Pastwa kraju. TR Dilinizdeki kullanma ve montaj talimat, retici Truma'dan veya lkenizdeki Truma servisinden talep edilebilir. Truma Truma . iNet Box Installation Instructions Page 2 iNet Box Table of Contents Symbols used ........................................................................ 2 Installation Instructions Symbols used Safety instructions ............................................................. 3 Intended use .......................................................................... 3 Scope of delivery ................................................................... 3 Accessories ........................................................................... 3 Dimensions ............................................................................ 3 Connections .......................................................................... 3 Displays ................................................................................. 4 Selecting a location ............................................................... 4 Connection examples ............................................................ 5 Assembly ............................................................................... 7 The unit must only be installed and repaired by an expert. Note containing information and tips. 2 Installation Instructions Safety instructions Dimensions In-vehicle installations must comply with the technical and administrative regula-
tions of the respective country of use (e.g. EN 1648, VDE 0100-721). National regula-
tions and rules must be followed. In other countries, the relevant regulations must be observed. Intended use The iNet Box was developed for controlling TIN-bus-capable Truma devices via mobile terminal devices (e.g. smartphones, tablet PCs). Communication is via Bluetooth or GSM. L x W x H 147 x 96 x 40 The dimensions are in mm Scope of delivery 1 iNet Box 1 Fastening bracket 1 Set of operating instructions 1 Set of installation instructions 1 12 V connector cable 30 cm (+ = red , - = blue) 1 Connector cable (TIN-bus) Accessories External GSM antenna TIN-bus cable, 3 different lengths Connections Front view POWER (9 V 29 V operating voltage) TIN 1 TIN 2 3 Rear view Selecting a location Install the iNet Box in a location that is protected from mois-
ture and humidity. For optimum transmission and reception, secure the iNet Box as high up as possible, e.g. above a win-
dow and in the middle of the vehicle. At the same time, due to the position of the installed antennae, the connections should go upwards or downwards (secure the box perpendic-
ular on the wall). 1 BLUETOOTH / factory settings button 2 Mini-SIM (25 x 15 mm) 3 External antenna connection GSM (SMA) 4 Changeover switch, internal / external antenna GSM The slot for the Mini-SIM and the external GSM antenna connection, the internal / external antenna changeover switch and the button for the BLUETOOTH pairing must remain accessible. Displays Top view Connect the external GSM antenna People must maintain a distance of at least 20 cm from the antenna.
(BLUETOOTH pairing status) Blue LED Green LED (POWER lights up during operation) Red LED
(GSM) lights up when GSM operation is not possible. 4 Connection examples Plug the cable (TIN-bus) into the iNet Box TIN 1/2 and con-
nect it to a TIN-capable heater and/or air conditioning sys-
tem (from 01.04.2015 onwards, the heater can only be operated in conjunction with a CPplus control panel). Plug in the 12 V connector cable and attach to unswitched 12V operating voltage (permanent positive). Protect the positive cable with a 1 A fuse (near to the positive terminal of the power source). When the CPplus control panel is used, the same circuit as that of the iNet Box must be used. Figure 2 Figure 1 Figure 3 5 Figure 4 Figure 6 Figure 5 6 Figure 7 Assembly Initial start-up should be carried out before starting assembly Download the app to the mobile phone Establish the Bluetooth connection to the iNet Box Search for the location with the best Bluetooth reception Establish the position of the iNet Box (safety clearance >20cm from people). Fix the iNet Box to the wall at the established position using the two adhesive strips (the surface must be clean and smooth). Lay the iNet Box cables clear of the 230 V cables (approx. 20cm) . The cables must have strain relief. Subject to technical changes. 7 Bei Strungen wenden Sie sich bitte an das Truma Servicezentrum oder an einen unserer autorisierten Servicepartner (siehe www.truma.com). Fr eine rasche Bearbeitung halten Sie bitte Gertetyp und Seriennummer (siehe Typenschild) bereit. Should problems occur, please contact the Truma Service Centre or one of our authorised service partners
(see www.truma.com). In order to avoid delays, please have the unit model and serial number ready (see type plate). Veuillez vous adresser au centre de SAV Truma ou un de nos partenaires de SAV agrs en cas de dysfonctionnements
(voir www.truma.com). Pour un traitement rapide de votre demande, veuillez tenir prts le type dappareil et le numro de srie (voir plaque signaltique). In caso di guasti rivolgersi al centro di assistenza Truma o a un nostro partner di assistenza autorizzato
(consultare il sito www.truma.com). Affinch la richiesta possa essere elaborata rapidamente, tenere a portata di mano il modello dellapparecchio e il numero di matricola (vedere targa dati). 4 1 0 2
/
2 1 1 0 0 0 1 5 1
-
0 0 0 0 5 Truma Gertetechnik GmbH & Co. KG Wernher-von-Braun-Strae 12 85640 Putzbrunn Deutschland Service Telefon +49 (0)89-4617-2020 Telefax +49 (0)89 4617-2159 service@truma.com www.truma.com Bei Strungen wenden Sie sich bitte an das Truma Servicezentrum oder an einen unserer autorisierten Servicepartner (siehe www.truma.com). Fr eine rasche Bearbeitung halten Sie bitte Gertetyp und Seriennummer (siehe Typenschild) bereit. Should problems occur, please contact the Truma Service Centre or one of our authorised service partners
(see www.truma.com). In order to avoid delays, please have the unit model and serial number ready (see type plate). Veuillez vous adresser au centre de SAV Truma ou un de nos partenaires de SAV agrs en cas de dysfonctionnements
(voir www.truma.com). Pour un traitement rapide de votre demande, veuillez tenir prts le type dappareil et le numro de srie (voir plaque signaltique). In caso di guasti rivolgersi al centro di assistenza Truma o a un nostro partner di assistenza autorizzato
(consultare il sito www.truma.com). Affinch la richiesta possa essere elaborata rapidamente, tenere a portata di mano il modello dellapparecchio e il numero di matricola (vedere targa dati). 4 1 0 2
/
2 1 1 0 0 0 2 5 1
-
0 5 0 0 5 Truma Gertetechnik GmbH & Co. KG Wernher-von-Braun-Strae 12 85640 Putzbrunn Deutschland Service Telefon +49 (0)89-4617-2020 Telefax +49 (0)89 4617-2159 service@truma.com www.truma.com