DC COMPRESSOR DUAL ZONE FRIDGE-FREEZER MODEL: Truma Cooler C69 DZ US, Truma Cooler C85 DZ US, Truma Cooler C96 DZ US INSTRUCTION MANUAL
- 1 -
Congratulations on the purchase of this quality Refrigerator-Freezer. We the manufacturer trust that you will enjoy many years of trouble free use. Please read the instructions carefully before using your Refrigerator - Freezer. This book will provide you with information on how to operate and care for your Refrigerator-Freezer in order to gain the maximum benefit from it. Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (
2) this device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
(1) lappareil ne doit pas produire de brouillage, et
(2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help. FCC& IC Radiation Exposure Statement:
This equipment complies with FCC and Canada radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Dclaration dIC sur lexposition aux radiations:
Cet quipement est conforme aux limites dexposition aux radiations dfinies par le Canada pour des environnements non contrls. Cet metteur ne doit pas tre install au mme endroit ni utilis avec une autre antenne ou un autre metteur.
- 2 -
Warning:
1This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. 2Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance. 3This appliance is intended to be used in household and similar applications such as staff kitchen areas in shops, offices and other working environments;
farm houses and by clients in hotels, motels and other residential type environments;
bed and breakfast type environments;
catering and similar non-retail applications 4) The appliance suitable for camping use;
5) The appliance shall not be exposed to rain 6)The appliance must be earthed and connected to a suitable 100-240 volt or 12/24 volt socket. The manufacturer and the seller do not accept responsibility for any damage due to incorrect electrical installation. TEST-RUN DC input condition, the voltage range required is DC12-24V, if the power is not stable, the unit will not run. The unit will restart when the voltage is normal. AC input condition, the voltage range required is 100240V. Do not pull the appliance by power cord. Connect power, set the digital thermostat to -18 and check the indicators, 30 minutes later, open the door and check the inside surface. If the inside surface is cold, your appliance is working. Operation with AC100-240V/50Hz Connect the appliance to a AC100-240V power source using the removable AC cable supplied with the appliance. In the Temperature window the temperature last set will flash for 5 seconds and then automatically change to display the temperature inside the cabinet.
- 3 -
Press the Up or Down keys to set the temperature you require. The set temperature will flash for 5 seconds and then automatically change to display the temperature inside the cabinet. To turn off the appliance, remove the plug from socket. Operation with DC12V/DC24V Connect the DC cable supplied with the appliance to a suitable DC socket outlet .A 120 watt dc socket outlet is recommended. The appliance will automatically identify and apply DC12V or DC24V. The LED light 12V (Noted: 12V and 100-240V share the same light) or 24V will illuminate to indicate the appliance is working. In the Temperature window the digital temperature last set will flash for 5 seconds and then automatically change to display the temperature inside the cabinet. Press the Up or Down keystrokes to set the temperature you required. The set temperature will flash for 5 seconds and then automatically change to display the temperature inside the cabinet. To turn off the appliance, remove the DC plug from the DC socket. NOTE: When using 24V and 100-240V together, make sure to plug in 100-240V power cord first then the 24V power cord. Otherwise the appliance will BEEP indicating low voltage. This is not a malfunction. CONTROL PANEL:
1 2 3 4 5 6 7 1. ON/OFF switch button 2. ECO and TURBO switch button 3. Turbo running indicator 4. Faulty LED indicator 5. LED display 6. Function selector
- 4 -
7. Temperature setting button POWER SOCKET PANEL:
Front side:
The USB socket in the above panel is 5V/3A. it is normally for electrical appliance charge or LED light charge. It is forbidden to charge the appliance which is not within voltage range. When you switch on the Emergency override, the control panel is out of use, compressor will keep on running. It is suggested to use only when the control panel is out of function. Fridge power consumption is higher when use emergency override, but battery protect function is still working. Back side:
Both sides DC socket have the same function. MAINTENANCE AND REGULAR CLEANING Always disconnect the power supply before cleaning. Clean the inside of the cabinet whenever necessary using a warm solution of water and bicarbonate of soda(1 tablespoon to every 2 liters of water) dry with a soft cloth Dirt from the condenser should be cleaned by a qualified technician when necessary. NOT A MALFUNCTION It is normal to hear gurgling sounds caused by the flow of refrigerant when each cooling cycle ends. The surface temperature of the compressor can reach 70-90 when running. The noise emitted by the cooling fan on the condenser is a normal condition.
- 5 -
MAIN TECHNICAL PARAMETER MODEL Truma Cooler C96 DZ US Truma Cooler C85 DZ US Truma Cooler C69 DZ US VOLUME 96L 85L 68.5L 100V-240V~
100V-240V~
100V-240V~
VOLTAGE 50~60Hz 50~60Hz 50~60Hz INPUT CURRENT DC POWER AND CURRENT 0.55A at AC240V 0.55A at AC240V 0.53A at AC240V 5A at 12V 5A at 12V 5A at 12V 2.5A at 24V 2.5A at 24V 2.5A at 24V GAS R134a / 98GRAMS R134a / 98GRAMS R134a / 70GRAMS FOAMING C-Pentane C-Pentane C-Pentane LOWEST TEMP. HIGHEST TEMP.
-22C
+10C NET WEIGHT 31.8
-22C
-22C
+10C 29.8
+10C 27.2 DIMENSION W912*D536*H500 W912*D536*H420 W732*D456*H555 SAFTY:
A separate earthed 15A socket outlet should be used on 100-240V AC and at least a 120W DC socket on 12/24V DC. In the event of any malfunction of your freezer, please contact the nearest service agent. CIRCUIT DIAGRAM
- 6 -
TROUBLESHOOTING problem Cause Remedy The compressor runs for 15 minutes and stops The voltage is not in the normal range The compressor runs but inner liner does not get cold The refrigerant has leaked The system is blocked The inner liner is very cold and the compressor runs continuously. The door is being opened and closed too frequently The condenser is not well-ventilated. The controller is faulty Switch off power and restart when power is normal Contact your local dealer The door should be opened as little as possible Select a well-ventilated place The compressor does not run
+ and - are switched. Rectify The controller is faulty(the power indicator is not on) The thermostat is set too high;
the ambient temperature is too low. The freezer is not placed properly. Contact your local dealer Use as a freezer Make the freezer level The freezer is noisy Some parts have come loose. Contact your local dealer The pipes are touching. Contact your local dealer
- 7 -
1 Flash every 4 seconds Low Voltage 2 Flashes every 4 seconds: fan issue 3 Flashes every 4 seconds Fan issue compressor start issue 4 Flashes every 4 seconds: low motor speed low motor speed 5 Flashes seconds every 4 over temperature Try on different power source (vehicle or 240V AC power). If changing power source fixed, then possible issue with the original power source. Ensure cabling between fridge and battery is at least 4mm, if the distance is more than 2 meters then use at least 6 mm cable. Fan is drawing too many Amps Amps), replace fan. Unplug cable and allow unit to rest for 10 minutes. Try on different power source (vehicle or 240V AC power) Electronic box fault. Compressor fault. Reduce products /items inside unit. Move so unit is in a lower
(over ambient temperature;
clean vents/ensure clear air flow over compressor. Fan fault. Ambient temperature too high. Clean vents
/ ensure clear air flow over compressor Fan fault. MOVEMENT AND INSTALLATION When moving the freezer, the angel between the cabinet and the ground should not be less than 45o in order to protect the compressor and refrigerating system. Position the freezer in a dry and well-ventilated place. Keep the freezer away from
- 8 -
direct sunlight, heaters and corrosive gases. The normal operation of the freezer depends on the heat radiation of the condenser. For the initial use, the packing foam must be taken off and at least 150mm space must be left around the freezer. CORRECT DISPOSAL OF THIS PRODUCT:
This symbol on the product, or in its packaging, indicates that this product may not be treated as household waste. Instead, it should be taken to the appropriate waste collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by the inappropriate waste handling of this product. For more detailed information about the recycling of this product, please contact your local council, your household waste disposal service, or the shop where you purchased the product.
- 9 -