ZigbeePIRMotionSensorwithPetImmunity H74426 InstallationInstructionsandUserManual 1. Specifications Frequency:
OperatingTemperature:
OperatingHumidity:
Battery:
BatteryLife:
Compatibility:
PetImmunity:
CoverageArea:
LightImmunity:
CoveragePattern:
7.5 ft SideView:
2.4GHz(IEEE802.15.4) 32113F(045C) 85%RHnoncondensing 1xCR123APanasonicLithium3VDC 3Years Zigbee, WWAH(WorkswithAllHubs) Upto50lbs 40feetby40feet,90angle 1500Lux 03610131619232629333640
(feet) TopView:
0 3 6 10 13 16 19 23 26 29 33 36 40 0 3 6 10 13 16 19 23 26 29 33 36 40
f e e t
) 2926231916139630369131619232629
(feet) 2. PackageContents 1xSensor 4xScrews&WallAnchor 2xSensorCaseScrew 1xManual 1xCR123Abattery(installed) 1xBackMounting2SidedAdhesiveTape 2xSideMounting2SidedAdhesiveTape 3. ComponentIdentification 6. WalkTestMode TamperSwitch CR123ABattery CaseReleaseButton SensorCaseScrews 4. ZigbeeEnrollment:
ThisPIRMotionSensorneedstobepairedbeforeinstallation. 1. Pulltheexposedplasticbatterytab. 2. TheLEDwillblinkthreetimesevery23secondsinambercolorwhile 3. 4. scanningthenetwork. Ifnetworkisfoundandsuccessfullyjoined,theLEDwillbelitfor1secondin ambercolorfollowedbyashortblinkingreencolor. Ifnetworkisnotfoundafter1minute,thesensorwillgointosleepmode andtheLEDwillblinkinambercolorevery1minute.Youneedtoresetthe sensortotriggerapairingprocess,andthensensorwillrepeatstepsfrom2 to4. Toresetthesensor:
1. Removethebatteryfor10seconds 2. Pressandholddownthetemperswitchwhilereinsertthebattery 3. Releasethetemperswitchwithin3seconds 5. Mounting MountthePIRMotionSensorat7.5feet(2.3meters)abovethefloor. Pressthecasereleasebuttontoseparatethefrontandbacksensorcase. Thebackcasegivesaccesstoboththeflushmountandcornermount screwknockouts.Drillthroughtheappropriateknockoutsandusethe includedscrewstomountinthedesiredmountinglocation. Itisrecommendedtoensurethereisatightsealaroundtheknockoutsto preventbugsfromenteringthesensorandcausingfalsealarms. Replacethefrontsensorcovertosnapshutandscrewinthesensorcase screwsonthetopandbottomofthebacksensorcase. Walktestmodecanbeusedtotestthemotionsensordetectioncoveragearea. Toenterwalktestmode:
1. Removethebatteryfor10seconds 2. Pressandholddownthetamperbuttonwhilereinsertthebattery 3. Keepthetamperswitchholddownfor10secondsthenrelease TheLEDwillbegintoblinkslowlyinambertoindicatesthemotionsensoris warmingup.After45seconds,theLEDwillstopblinkingwhichindicatesthe motionsensorisreadytodetectmotion.TheLEDwillbelitinredcolorto illuminateeachtimemotionisdetected.OncetheLEDgoesout,thesensoris readytodetectmotionagain.Walktestmodeendsafter20motionsdetected, ornomotiondetectedfor1minutes.ItisrecommendedthatthePIRZB2ECOis testedmonthlytoensureproperfunction. 7. Operation ThePIRMotionSensorrequires45secondstowarmupforsignalstabilizing whenperformingstartuporreset.Duringthewarmupperiod,theLEDwillblink slowlyinamber. Afterwarmupcompleted,theLEDwillblinkevery5minutesingreencolorto indicatethesensorisworkingproperly.However,therearenoLEDindications whenmotionisdetected.Thisisdonetomaximizebatterylife.Furthermore, whenmotionisdetectedandasignalistransmittedtothepanel,thesensorwill nottransmitagainuntiltherearenomotiondetectedforaperiodof3minutes andmotionisdetectedagain. 8. MaintenanceReplacingtheBattery Whenthebatteryislow,asignalwillbesenttothecontrolpanel.TheLEDwill blinkevery2minutesinred. Toinsertorreplacethebattery:
1. Pressthecasereleasebuttontoseparatethefrontandbacksensorcase 2. Removethefrontcasetoexposethebattery 3. ReplacetheCR123Alithiumbattery.Notethecorrectorientationofthe batteryasshownonthebatterycompartment. 4. Replacethefrontcover. WARNING:Failuretofollowthesewarningsandinstructionscanleadtoheat generation,rupture,leakage,explosion,fire,orotherinjury,ordamage.Donot insertthebatteryintothecompartmentinthewrongdirection.Alwaysreplace thebatterywiththesameorequivalenttype(seeSpecificationsonsection1). Neverrechargeordisassemblethebattery.Neverplacethebatteryinfireor water.Alwayskeepbatteriesawayfromsmallchildren.Ifbatteriesare swallowed,promptlyseeadoctor. Alwaysdisposeand/orrecycleusedbatteriesinaccordancewiththehazardous wasterecoveryandrecyclingregulationsforyourlocation.Yourcity,state,or countrymayalsorequireyoutocomplywithadditionalhandling,recycling,and disposalrequirements. 9. `EnvironmentalandOtherUsefulInformation 5. WhilethePIRisahighlyreliableintrusiondetectiondevice,itdoesnotguaranteeagainst burglary.Anyintrusiondeviceissubjecttoafailuretowarnforavarietyofreasons. ConsiderthefollowingwheninstallingandsettingupthePIR:
6. ThisPIRhasbuiltinprotectiontokeepbugsfromgettingintothesensorareaandcausing 7. falsealarms.Notethatthisprotectiondoesnotpreventinsectsfromcrawlingacrossthelens ofthePIR,whichcouldtriggerthePIR. Infraredenergycanbereflectedoffanyglossysurfacessuchasmirrors,windows,floors,or countertopswithglossyfinish,andslickfinishedconcrete.Somesurfacesreflectlessthan others(e.g.thePIRcanseeachangeininfraredenergyoffofreflectivesurfacesevenifthe heatorcoldsourceisnotwithinthePIRdetectionpattern). 8. Windowsreflectinfraredenergy.Theyalsoallowsunlightorlightfromothersources(e.g., cars)topassthroughtothePIR.ThePIRcandetectthesechangesininfraredenergy.For example,ifsunlightpassingthroughawindowshinesontoahardwoodfloorandthechange ininfraredenergyisquickenough,thePIRcantriggeranalarm.ThesameappliesifthePIR areaincludesawindow,eventhoughthepatternofprotectioncannotseethroughglass. Lightsfromapassingcarcanalsopassthroughthewindowatnightandshinedirectlyintothe PIRslens. 9. Heatingandairconditioningductsarealsoimportantbecauseiftheyblowairontoanobject withinthefieldofthePIRsview,thetemperatureofthatobjectcouldchangequicklyenough forthePIRtoseeachangeininfraredenergy.PIRscannotseeaircurrent,onlythechange intemperatureofaphysicalobject. 10. ThePIRsenseschangeintemperature.However,astheambienttemperatureofthe protectedareaapproachesthetemperaturerangeof95to120F,thedetection performanceofthePIRdecreases. 11. EnsurethattheareayouwishthePIRtocoverisfreeofobstructions(forexample,curtains, screens,plants,andsoon.)thatmayblockthepatternofcoverage. 12. Anythingthatcanswayormoveduetoaircurrentcancauseachangeininfraredenergy withinthefieldsofview.Draftsfromdoorsorwindowscancausethistohappen.Plants, balloons,curtains,andhangingbasketsshouldneverbeleftinthePIRsfieldofview. 13. DonotmountthePIRonasurfacethatallowsforanyvibration.Vibrationsnotonlycausethe PIRtomovealittle,butitalsocausesthefieldsofviewinaroomtomovewithrespectthe PIR.AlittlevibrationcancausehavocwiththePIRsfieldofview,thusthePIRmayseea changeinenergyandtriggerthealarm. 14. AninstallationoftenrequiresthatthePIRisaimedatthedoor.ThePIRmaydetectdoor movementbeforethedoorcontactcaninitiateanentrydelay,causingthealarmtotrigger.If youinstallthePIRfacingadoor,thenwhileprogrammingthePIR,chooseanappropriate sensor/zonetype. 15. ThePIRONLYdetectsintrusionwithinthepatternofcoverage. 16. ThePIRdoesnotprovidevolumetricareaprotection. 17. ThePIRcreatesmultiplebeamsofprotection.Intrusioncanonlybedetectedinunobstructed areascoveredbythosebeams. 18. ThePIRcannotdetectmotionorintrusionthatoccursbehindwalls,ceilings,floors,closed doors,partitions,glassdoors,orwindows. 19. Tamperingwith,masking,painting,orsprayingofanymaterialonthePIRlensoranypartof theopticalsystemcanimpairdetectionability. 20. ThePIR,likeotherelectricaldevices,aresubjecttocomponentfailure.EventhoughthePIRis designedtolastaslongas10years,theelectroniccomponentsaresubjecttofailure. FCCComplianceStatement Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1)This devicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,including interferencethatmaycauseundesiredoperation. ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforClassBdigitaldevices,pursuanttoPart 15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferencein aresidentialinstallation.Thisequipmentgeneratesusesandcanradiateradiofrequencyenergyand,ifnot installedandusedinaccordancewiththeinstructionmanual,maycauseharmfulinterferencetoradio communications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.If thisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedby turningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreof thefollowingmeasures:
Reorientorrelocatethereceivingantenna Increasetheseparationbetweentheequipmentandreceiver Connecttheequipmenttoanoutletonadifferentcircuitfromthereceiver Consultthedealeroranexperiencedradio/TVcontractorforhelp. Theuseriscautionedthatchangesandmodificationsmadetotheequipmentwithouttheapprovalof manufacturercouldvoidtheuser'sauthoritytooperatethisequipment. FCCRadiationExposureStatement ThisequipmentcomplieswithFCCRFradiationexposurelimitssentforthforanuncontrolledenvironment.This equipmentshouldbeinstalledandoperatedwithaminimumdistanceof20centimetersbetweentheradiator andyourbody.Theantennasusedforthistransmittermustbeinstalledtoprovideaseparationdistanceofat least20cmfromallpersonsandmustnotbecolocatedoroperationinconjunctionwithanyotherantennaor transmitter. IndustryCanadarequirements ThisdevicecomplieswithIndustryCanadalicenseexemptRSSstandard(s).Operationissubjecttothefollowing twoconditions:(1)thisdevicemaynotcauseinterferenceand(2)thisdevicemustacceptanyinterference, includinginterferencethatmaycauseundesiredoperationofthedevice LepresentappareilestconformeauxCNRd'IndustrieCanadaapplicablesauxappareilsradioexemptsde licence.L'exploitationestautoriseauxdeuxconditionssuivantes:(1)l'appareilnedoitpasproduirede brouillage,et(2)l'utilisateurdel'appareildoitacceptertoutbrouillageradiolectriquesubi,mmesile brouillageestsusceptibled'encompromettrelefonctionnement CanadaRFexposurecompliance TocomplywithRSS102requirements,aseparationdistanceof20cmmustbekeptbetweenthedeviceandthe useratalltimes. PourseconformerauxexigencesRSS102,unedistancedesparationde20cmdoittremaintenueentre l'appareiletl'utilisateurtoutmoment. FCCID:MG3H74426IC:2575AH74426 UniversalElectronicsInc. PN:470070013520 REV&REVDate:A0301/28/2022