all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Users manual | Users Manual | 2.30 MiB | January 09 2004 | |||
1 | Operational Description | January 09 2004 | ||||||
1 | Attestation Statements | January 09 2004 | ||||||
1 | External Photos | January 09 2004 | ||||||
1 | ID Label/Location Info | January 09 2004 | ||||||
1 | Internal Photos | January 09 2004 | ||||||
1 | Operational Description | January 09 2004 | ||||||
1 | RF Exposure Info | January 09 2004 | ||||||
1 | RF Exposure Info | January 09 2004 | ||||||
1 | RF Exposure Info | January 09 2004 | ||||||
1 | Operational Description | January 09 2004 | ||||||
1 | Test Report | January 09 2004 | ||||||
1 | Test Report | January 09 2004 | ||||||
1 | Test Setup Photos | January 09 2004 | ||||||
1 | Parts List/Tune Up Info | October 09 2004 | ||||||
1 | Parts List/Tune Up Info | January 09 2004 |
1 | Users manual | Users Manual | 2.30 MiB | January 09 2004 |
Omni 5xxx Installation Guide R I F F I D O E R L T N N A E T I A F E N V O C VeriFone Part Number 23216, Revision A.1 Omni 5xxx Installation Guide 2004 VeriFone, Inc. All rights reserved. No part of the contents of this document may be reproduced or transmitted in any form without the written permission of VeriFone, Inc. The information contained in this document is subject to change without notice. Although VeriFone has attempted to ensure the accuracy of the contents of this document, this document may include errors or omissions. The examples and sample programs are for illustration only and may not be suited for your purpose. You should verify the applicability of any example or sample program before placing the software into productive use. This document, including without limitation the examples and software programs, is supplied As-Is. VeriFone, the VeriFone logo, Omni, VeriCentre, Verix, and ZonTalk are registered trademarks of VeriFone. Other brand names or trademarks associated with VeriFones products and services are trademarks of VeriFone, Inc. All other brand names and trademarks appearing in this manual are the property of their respective holders. Comments? Please e-mail all comments in this document to Tell_Us_More@VeriFone.com WARNING Do not dispose of the Li-ion smart battery in a fire. Li-ion batteries must be recycled or disposed of properly. Do not dispose of Li-ion batteries in municipal waste sites. VeriFone, Inc. 2455 Augustine Drive Santa Clara CA 95054-3002 www.verifone.com VeriFone Part Number 23216, Revision A.1 C H A PT ER 1 Terminal Overview Features and Benefits . 10 Exceptional Ease of Use . 10 Countertop Performance in a Hand-Over Design. 10 True Multi-Application Capability . 10 PR E FA C E . . . . . . . . . . . . . . . . . . . . . . . . . 5 CONTENTS Audience. 5 Organization . 5 Related Documentation . 5 Conventions and Acronyms . 6 Document Conventions. 6 Acronym Definitions . 6 N N O E R I F F I D L T E T I A F A N R Select Terminal Location . 11 Ease of Use . 11 Environmental Factors . 11 Electrical Considerations . 11 Unpack the Shipping Carton. 12 Examine Terminal Features . 13 Front Panel . 13 Connection Ports . 14 Establish Telephone Line Connections . 15 Install Paper Roll . 16 Install/Replace MSAM Cards . 18 Connect Optional Device(s) . 19 Connect PIN Pad or Smart Card Reader . 20 Connect Check Reader. 21 External Printers Supported . 22 Connect Terminal Power Pack . 22 Smart Card Transaction . 23 Magnetic Card Reader Use . 23 C H A PT ER 2 Terminal Setup E V O C C H A PT ER 3 Specifications C H A PT ER 4 Maintenance Power . 25 DC Power Pack . 25 Temperature . 25 External Dimensions. 25 Weight . 25 Clean the Terminal . 27 Smart Card Reader . 27 OMNI 5XXX INSTALLATION GUIDE 3 CONTENTS C H A PT E R 5 VeriFone Service and Support C H A PT E R 6 Troubleshooting Guidelines E N V O C Return a Terminal for Service. 29 Accessories and Documentation . 30 Power Pack. 31 Thermal Printer Paper. 31 VeriFone Cleaning Kit . 31 Telephone Line Cord . 31 Swivel Stand . 31 Documentation . 31 Blank Display . 33 Terminal Does Not Dial Out . 33 Printer Does Not Print. 34 Printer Paper Jam. 34 Peripheral Device Does Not Work . 34 Keypad Does Not Respond . 34 Transactions Fail To Process . 35 N R I F F I D L T E T I A F N A O E R 4 OMNI 5XXX INSTALLATION GUIDE PREFACE This guide is your primary source of information for setting up and installing the Omni 5xxx series of terminals. Audience This guide is useful for anyone installing and configuring a Omni 5xxx terminal. Basic descriptions of the terminal features are also provided. Organization This guide is organized as follows:
V O C Related Documentation L T Chapter 1, Terminal Overview. Provides an overview of the Omni 5xxx series of terminals. Chapter 2, Terminal Setup. Explains how to set up and install the Omni 5xxx terminal. It tells you how to select a location, establish power and telephone line connections, and how to configure optional peripheral devices. Chapter 3, Specifications. Discusses power requirements and dimensions of the Omni 5xxx terminal. Chapter 4, Maintenance. Explains how to maintain your Omni 5xxx terminal. Chapter 5, VeriFone Service and Support. Provides information on contacting your local VeriFone representative or service provider, and information on how to order accessories or documentation from VeriFone. R I F F I D O E E N Chapter 6, Troubleshooting Guidelines. Provides troubleshooting guidelines, should you encounter a problem in terminal installation and configuration. N N A To learn more about the Omni 5xxx terminal, refer to the following set of documents:
E T I A F R Omni 5xxx Quick Installation Guide, VeriFone Part Number (VPN) - 23219 Omni 5xxx Certifications and Regulations, VPN - 23218 Omni 5xxx Reference Manual, VPN - 23217 Verix V Operating System Programmers Manual, VPN - 23230 Verix V Tools Programmers Manual, VPN - 23231 OMNI 5XXX INSTALLATION GUIDE 5
PREFACE Conventions and Acronyms Conventions and Acronyms This section describes conventions and acronyms used in this guide. Document Conventions Various conventions are used to help you quickly identify special formatting. Table 1 describes these conventions and provides examples of their use. Table 1 Document Conventions Convention Meaning Example See Conventions and Acronyms. You must install a roll of thermal-sensitive paper in the printer. http://www.verifone.com RS-232-type devices do not work with the PIN pad port. Blue Italics Courier NOTE E N V O C Text in blue indicates terms that are cross referenced. Italic typeface indicates book titles or emphasis. The courier type face is used while specifying onscreen text, such as text that you would enter at a command prompt, or to provide an URL. The pencil icon is used to highlight important information. O N N R I F F I D L T E T I A F A E R CAUTION The caution symbol indicates possible hardware or software failure, or loss of data. The terminal is not waterproof or dustproof, and is intended for indoor use only. WARNING The lighting symbol is used as a warning when bodily injury might occur. Due to risk of shock do not use the terminal near water. Acronym Definitions Various acronyms are used in place of the full definition. Table 2 presents acronyms and their definitions. Table 2 Acronym Definitions Acronym Definitions AC ATM CR EMV ITP LCD LED MRA MSAM PED Alternating Current Automated Teller Machine Check Reader Europay MasterCard and VISA Internal Thermal Printer Liquid Crystal Display Light Emitting Diode Merchandise Return Authorization Micromodule-Size Security Access Module PIN-Entry Devices 6 OMNI 5XXX INSTALLATION GUIDE PREFACE Conventions and Acronyms Table 2 Acronym Definitions (continued) Acronym Definitions PIN RJ45 RS-232 SAM VPN Personal Identification Number Registered Jack 45 Recommended Standard 232 Security Access Module VeriFone Part Number R I F F I D E N V O C L T N N A E T I A F O E R OMNI 5XXX INSTALLATION GUIDE 7 PREFACE Conventions and Acronyms R I F F I D E N V O C L T N N A E T I A F O E R 8 OMNI 5XXX INSTALLATION GUIDE CHAPTER 1 Terminal Overview This chapter provides a brief description of the Omni 5xxx series of terminals. This series includes the Omni 5100 and Omni 5150 terminals. The Omni 5xxx terminal series represents the shape of things to come in e-payment. The bold ergonomic design is sleek and stylish, offering countertop power and 32-bit performance in an integrated terminal that can be handed to the consumer for input. In addition, the Omni 5xxx series serves as the entry point to VeriFones acclaimed multi-application platformwith the capability to securely support payment and value-added applications on a single terminal. L N VeriFone ships variants of the Omni 5xxx terminal for different markets. Your terminal may have a different configuration. The following devices may or may not be present: a smart card reader, or zero or three MSAM cardholders. R I F F I D E T I A F O E N A R T E N NOTE C V O Features At a Glance
Delivers power and usability in a convenient hand-over design.
Securely supports and runs payment and value-added applications.
Multi-application operating environment.
Offers unsurpassed performance on EMV smart card transactions. 32-bit processing and multi-tasking capabilities.
Security architecture meets specifications for PED and sophisticated file authentication. OMNI 5XXX INSTALLATION GUIDE 9
TERMINAL OVERVIEW Features and Benefits Features and Benefits Omni 5xxx terminals provide the right combination of features and functions. This includes a triple-track magnetic-stripe card reader, smart card reader, integrated PIN pad, and a quiet, fast, ITP. Exceptional Ease of Use Bold design is sleek, stylish, and lightweight for conveniently handing the terminal to the consumer for PIN entry or other input. Intuitive ATM-style interface, large 8 line x 21 character backlit display with split screen capabilities, large keys, and extra-size menu prompts simplify training and reduce calls to the help desk. Integrated high-speed thermal printer simplifies paper loading and virtually eliminates paper jams. Triple-track, high-coercivity card reader handles most magnetic stripe cards. R I F F I D 32-bit processing and multi-tasking capabilities make short work of payment, payment-related, and value-added applications. Exceptional graphics-handling capabilities of display and printer quickly render logos, graphical fonts, and character-based languages. VeriCentre Appliance Management Suite employs advanced file compression to streamline simultaneous downloads of application software to hundreds of terminals. Integrated PIN pad offers added convenience to handle PIN-based applications. E T I A F Ensures uncompromising reliability from VeriFone, the worldwide leader in e-payment. 3 MB or 4 MB of memory and the dynamic memory allocation of the Verix V OS, support two or three typical-sized applications on a single terminal. Primary smart card reader and the MSAMs safeguard sensitive financial data and support multiple smart card schemes. O E R L T N N A Countertop Performance in a Hand-Over Design E N V O True Multi-
Application Capability C Omni 5xxx series of terminals and SoftPay EMV software have received EMV Level 1 and Level 2 Type approval for smart card solutions. The Verix EMV Library provides efficient development of other EMV-compliant applications. VeriShield security architecture meets published specifications for PED and provides sophisticated file authentication, to prevent execution of unauthorized software on Omni 5xxx terminals. 10 OMNI 5XXX INSTALLATION GUIDE
Terminal Setup This chapter describes the terminal setup procedure. You will learn how to:
CHAPTER 2 Select a Location and Protect the Terminal From Adverse Environmental Factors. L T Unpack the Shipping Carton. Examine Terminal Features. Establish Telephone Line Connections. Install Paper Roll in the Printer. Connect Optional Device(s). Connect Terminal Power Pack. O E R I F F I D N N A E T I A F R E N V O C Conduct Smart Card or Credit/Debit Transactions. See Smart Card Transaction and Magnetic Card Reader Use. Select Terminal Location Use the following guidelines while selecting a location for your Omni 5xxx terminal. Ease of Use Select a location convenient for both merchant and cardholder. Select a flat support surface, such as a countertop or table. Select a location near a power outlet and a telephone/modem line connection. For safety, do not string the power cord in a walkway or place across a walkway on the floor. Environmental Factors Do not use the terminal where there is high heat, dust, humidity, moisture, or caustic chemicals or oils. Keep the terminal away from direct sunlight and anything that radiates heat, such as a stove or motor. Do not use the terminal outdoors. CAUTION The terminal is not waterproof or dustproof, and is intended for indoor use only. Any damage to the unit from exposure to rain or dust may void any warranty. Electrical Considerations Avoid using this product during electrical storms. Avoid locations near electrical appliances or other devices that cause excessive voltage fluctuations or emit electrical noise (for example, air OMNI 5XXX INSTALLATION GUIDE 11
TERMINAL SETUP Unpack the Shipping Carton conditioners, electric motors, neon signs, high-frequency or magnetic security devices, or computer equipment). Do not use the terminal near water or in moist conditions. WARNING Due to risk of shock or terminal damage, do not use the terminal near water, in a wet basement, bathtub, wash bowl, kitchen sink, laundry tub, or near a swimming pool. Open the shipping carton and carefully inspect its contents for possible tampering or shipping damage. The Omni 5xxx is a secure product and any tampering may cause the terminal to cease to function properly. Unpack the Shipping Carton E N V O C OMNI 5XXX TERMINAL R I F F I D L UNIVERSAL POWER CORD E T I A F TELEPHONE LINE CORD POWER PACK T PAPER ROLL N N A O E R Figure 1 1 Remove and inspect the following items (see Figure 1):
Omni 5xxx Product Components Omni 5xxx terminal Power pack Telephone line cord Power cord Battery pack Paper roll 2 Remove all plastic wrapping from the terminal and other components. 3 Remove the clear protective film from the LCD screen. CAUTION Do not use a terminal that has been damaged or tampered with. The Omni 5xxx terminal comes equipped with tamper-evident labels. If a label or component appears damaged, please notify the shipping company and your VeriFone representative or service provider immediately. 12 OMNI 5XXX INSTALLATION GUIDE
TERMINAL SETUP Examine Terminal Features 4 Save the shipping carton and packing material for future repacking or moving the terminal. Before you continue the installation process notice the features of the Omni 5xxx terminal (see Figure 2). Examine Terminal Features INTERNAL THERMAL PRINTER SERRATED METAL STRIP CONNECTION PORTS
(BOTTOM) TERMINAL DISPLAY ALPHA KEY R I F F I D CANCEL KEY TELEPHONE-STYLE KEYPAD SAM COMPARTMENT
(BOTTOM) E N N N O E A R E T I A F Figure 2 Omni 5xxx Terminal Features (Front Panel) Front Panel The front panel includes the following features:
A terminal display, backlit LCD screen. Five types of keys:
V O C PRINTER COVER RELEASE GREEN INDICATOR LED MAGNETIC CARD READER L ATM-STYLE FUNCTION KEYS PROGRAMMABLE FUNCTION KEYS ENTER KEY BACKSPACE/CLEAR KEY SMART CARD READER T A 12-key, telephone-style keypad. Four ATM-style function keys, labeled F1 to F4, to the right of the LCD screen. Four unlabeled, programmable function keys above the keypad. Three color-coded function keys below the keypad (icons at right, left-to-right: CANCEL, BACKSPACE/CLEAR, ENTER). An ALPHA key centered at the top of the keypad. A magnetic card reader, built into the right side. The icon at right shows the proper swipe direction, with the stripe down and facing inward, toward the keypad. A green indicator LED indicates power is ON. OMNI 5XXX INSTALLATION GUIDE 13
TERMINAL SETUP Examine Terminal Features NOTE Connection Ports E N V O C An internal thermal printer. The smart battery pack installed in back of unit. A smart card reader, built into the front of the terminal. The icon shown at right indicates proper card position and insertion direction. A SAM (security access module) compartment, built into the bottom of the terminal. The Omni 5xxx terminal contains MSAM cardholders to support multiple stored-value card programs or other merchant card requirements. VeriFone ships variants of the Omni 5xxx terminal for different markets. Your terminal may have a different configuration. The following devices may or may not be present: a smart card reader, or zero or three MSAM cardholders. However, the basic processes described in this guide remain the same, regardless of terminal configuration. Turn the terminal upside down to view the connection ports. Notice that the ports are recessed. Different ports are provided to connect the Omni 5xxx to a communications line, optional peripheral devices, and the power supply (see Figure 3). L T N N O E A R E T I A F R I F F I D Figure 3 Connection Ports (Bottom View) The communications port can be identified by an telephone shaped icon, shown at right. Use this port to connect the Omni 5xxx to a phone line. Two RJ45-type modular jacks (serial ports) are available for attaching optional peripheral devices. 14 OMNI 5XXX INSTALLATION GUIDE
TERMINAL SETUP Establish Telephone Line Connections The RS-232 port, icon shown at right, connects a VeriFone CR 600 check reader, 1000i check reader, or other peripheral device. The PIN pad port, icon shown at right, connects a external PIN pad or smart card reader. The power connection port uses a round barrel connector. It is identified by the electrical power icon shown at right. Use this port to connect the Omni 5xxx to the power pack to recharge the battery through the unit. WARNING Do not connect the terminal to the power supply until all the peripherals are attached. Establish Telephone Line Connections Connect the telephone cord to the communication port on the terminal, then route it directly to a telephone wall jack (see Figure 4). This is a direct connection, and the line is dedicated to the terminal. R I F F I D E N V O C L T N N O E A R E T I A F Figure 4 Direct Telephone Connection WARNING To reduce the risk of fire, use only No. 26AWG or larger telecommunication line cord. OMNI 5XXX INSTALLATION GUIDE 15
TERMINAL SETUP Install Paper Roll Install Paper Roll CAUTION A fast, quiet thermal printer is built in to the Omni 5xxx terminal. Before you can process transactions that require a receipt or record, you must install a roll of thermal-sensitive paper in the printer. The ITP uses a roll of single-ply, thermal-sensitive paper 57 millimeters (2.24 inches) wide and 25 meters (82 feet) long. A pink out-of-paper indicator line appears on the edge of the paper approximately 18 inches before the end of the roll. After this line appears, there is enough paper remaining on the roll to conclude at least one transaction. Poor-quality paper can jam printer and create excessive paper dust. To order high-quality VeriFone paper, refer to Accessories and Documentation. Store thermal paper in a dry, dark area. Handle thermal paper carefully: impact, friction, temperature, humidity, and oils affect the color and storage characteristics of the paper. Never load a roll of paper with folds, wrinkles, tears, or holes at the edges or in the print area. L T N N O E A R E T I A F R I F F I D E N V O C To Install a Paper Roll 1 Press down on the button located on the side of the terminal to unlatch the paper roll cover, then lift the cover up and back (see Figure 5). Figure 5 2 Remove any partial roll of paper in the printer tray by lifting up (see Figure 6). Opening the Printer Cover 16 OMNI 5XXX INSTALLATION GUIDE 3 Loosen the glued leading edge of the paper or remove the protective strip from the new roll of paper, unwind the paper roll past any glue residue. TERMINAL SETUP Install Paper Roll Figure 6 4 Hold the roll so the paper feeds from the bottom of the roll (see Figure 7). Removing Partial Paper Roll 5 Drop the paper roll into the printer tray. R I F F I D E V O C N L T N N O E A R E T I A F Figure 7 6 Pull paper up past glue residue from printer tray. Loading Paper Roll 7 Close the paper roll cover by gently pressing directly on the cover until it clicks shut, allowing a small amount of paper past the glue residue to extend outside the printer door. (see Figure 8). CAUTION To prevent the paper roll cover from damaging the print roller, always gently press down on the printer dust cover to close it. OMNI 5XXX INSTALLATION GUIDE 17 TERMINAL SETUP Install/Replace MSAM Cards Figure 8 8 Tear the paper off against the serrated metal strip in the printer. Closing Paper Roll Cover For paper ordering information, refer to Accessories and Documentation. R I F F I D the terminal. from scratches. O E R Install/Replace MSAM Cards When you first receive your Omni 5xxx terminal, you may need to install one or more MSAM cards or you may need to replace old cards. CAUTION Observe standard precautions for handling electrostatically sensitive devices. Electrostatic discharges can damage this equipment. VeriFone recommends using a grounded anti-static wrist strap. To change or install MSAMs 1 Remove the power cord and/or battery (see Smart Battery) from the bottom of 2 Place the terminal upside down on a soft, clean surface to protect the lens E N V O C 3 Remove the MSAM compartment door screw and rotate the door up and back to access the MSAM cardholders (see Figure 9). L T N N A E T I A F MSAM COMPARTMENT DOOR MSAM COMPARTMENT DOOR SCREW Figure 9 Opening MSAM Compartment Door 18 OMNI 5XXX INSTALLATION GUIDE TERMINAL SETUP Connect Optional Device(s) 4 Remove any previously installed MSAM card by sliding the card from the MSAM cardholder. 5 Install an MSAM card by aligning the card and carefully sliding it within the guides on the cover until it is fully inserted (see Figure 10). R I F F I D L T N N A E T I A F O E R Figure 10 Installing An MSAM Card Before inserting the MSAM card, position it as shown in Figure 10, with the cards gold contacts facing the smart car reader end of the terminal. The cardholder connector base has a set of contacts and a notch on one corner to ensure the MSAM card is positioned correctly. The MSAM card has a notch on one corner to ensure that it fits into the connector base in only one way. The MSAM compartment door will not close properly if the MSAM card(s) are installed incorrectly. N 6 Replace the MSAM compartment door and reinstall the screw (see Figure 11). E NOTE V O C Figure 11 Closing MSAM Compartment Door The Omni 5xxx supports some peripheral devices designed for use with electronic point-of-sale terminals. Connect Optional Device(s) OMNI 5XXX INSTALLATION GUIDE 19 TERMINAL SETUP Connect Optional Device(s) Use the two ports on the back panel to connect up to two optional devices. CAUTION Before connecting any peripheral device, remove the power cord from the bottom of the terminal and ensure that the green indicator LED is not lit. Reconnect the power cord only after you are finished connecting the peripheral device(s). For complete information about peripheral installation and use, refer to the user documentation supplied with those devices. The following sections discuss the most common optional devices supported by this terminal. Table 3 Optional Devices Supported Optional Device Connection Port CR 600 or CR1000i (check readers) Console PIN pad RS-232 Electronic Cash Register Smart Card Reader R I F F I D L T N N A RS232 PIN pad PIN pad RS232 PIN pad E T I A F O E R Use the following procedure to connect a PIN pad or smart card reader. 1 Insert the RJ45-type connector on the end of the PIN pad or smart card reader into the port on back of the peripheral device. To install a PINpad 101, PINpad 201, or PINpad 1000, position and insert the grommet to secure the cable connection. Other optional devices may be supported. For more information, please contact your VeriFone distributor. NOTE RS-232-type devices do not work on the PIN pad port; PIN pad-type devices do not work on the RS-232 port. If an optional peripheral device does not function correctly, check the port connection. E N V O C Connect PIN Pad or Smart Card Reader If a cable is not already connected to the smart card reader or PIN pad, insert the small modular plug on one end of the interface cable into the optional devices modular jack. 2 Insert the larger RJ45-type connector on the other end of the PIN pad cable into the PIN pad serial port on the bottom of the terminal. 20 OMNI 5XXX INSTALLATION GUIDE TERMINAL SETUP Connect Optional Device(s) Figure 12 provides an example of a smart card reader and PIN pad connection to the PIN pad serial port. R I F F I D L T N N A E T I A F O E R E N V O PIN PAD CONNECTION SMART CARD READER CONNECTION Figure 12 Example PIN Pad Serial Port Connections Connect Check Reader The Omni 5xxx terminal supports the CR 600 and CR 1000i check readers. Contact your VeriFone representative or visit the online store at www.store.verifone.com for information on these devices. Figure 13 provides an example of a peripheral connection to the RS-232 port. CAUTION Check readers require a separate power source. Before connecting a check reader or similar device, remove the power cord from the bottom of the terminal and ensure that the green indicator LED is not lit. C Figure 13 CR 600 Check Reader Connection OMNI 5XXX INSTALLATION GUIDE 21 TERMINAL SETUP Connect Terminal Power Pack External Printers Supported Connect Terminal Power Pack CAUTION E N NOTE V O C Although all Omni 5xxx variants have an internal thermal printer, it may be convenient to print larger print runs (for example, daily or weekly reports) to an external printer. The Omni 5xxx terminal supports the VeriFone P250, P350, P900, and P950 external printers. Contact your VeriFone representative or visit the online store at www.store.verifone.com for information on these devices. External printer connections are through the RS-232 port (see Figure 13). When you have finished connecting optional peripheral(s), you are ready to connect the Omni 5xxx terminal to the provided or supplied power source. Only use a VeriFone-supplied power pack. Using an incorrectly rated power supply may damage the terminal or cause it not to work as specified. Before connecting, ensure that the power supply being used to power the terminal matches the requirements specified on the bottom of the terminal. (see Chapter 3, Specifications, for detailed power supply specifications). Obtain the appropriately rated power supply before continuing. O 1 Insert the round barrel connector (see Figure 14) into the power port, identified by the icon at right. The bottom of the Omni 5xxx has an integrated cable retaining feature to secure the power cord to the terminal. R I F F I D L T N N A E T I A F E R Figure 14 Omni 5xxx Power Pack Connection a Route the cable through cable retainer to secure the power cord (see Figure 14). 2 Insert the AC power cord into the power pack. 3 Plug the AC power cord into a wall outlet or powered surge protector. WARNING Do not plug the power pack into an outdoor outlet or operate the terminal outdoors. Also, disconnecting power during a transaction may cause transaction data files not yet stored in terminal memory to be lost. 22 OMNI 5XXX INSTALLATION GUIDE TERMINAL SETUP Smart Battery NOTE To protect against possible damage caused by lightning strikes and electrical surges, consider installing a power surge protector. When the terminal has power, the terminal display lights and the green LED indicator remains lit. Smart Battery If an application is loaded in the terminal, it starts after the initial VeriFone copyright screen and displays a unique copyright screen. If no application is loaded in the terminal, DOWNLOAD NEEDED appears on screen after the initial VeriFone copyright screen. The Omni 5xxx wireless terminal uses an Li-ion smart battery (see Accessories and Documentation for ordering information). The internal logic of the smart battery prevents both overcharging and undercharging (a fault condition in which the battery level goes well below the minimum acceptable charge and the battery becomes unusable). CAUTION Note that a new Li-ion batterys full performance is achieved only after two or three complete charge and discharge cycles. On initial use, allow the Omni 5xxx smart battery to charge 24 hours, then fully discharge during normal operation, to ensure reliable battery operation. R I F F I D L T N N A E T I A F O E R monitors state of charge (voltage and current), communicates with the terminal (charge parameters and alarms to indicate full discharge), determines full charge capacity (on charge cycle and uninterrupted discharge cycle), and The following are features of the smart battery:
Two Li-ion cells A fuel gauge module E N V O C automatically shuts down when cell voltage is extremely low. A safety circuit prevents cell damage from overcharge/over-discharge, activates when the battery is left in an unused terminal for extended periods, and resets when battery voltage reaches a preset threshold during the charge cycle. NOTE Conserve battery power by turning the Omni 5xxx terminal off when not in use. If the terminal is not to be used for several days, remove the battery from the terminal as it continues to discharge even when the terminal is turned off. OMNI 5XXX INSTALLATION GUIDE 23
TERMINAL SETUP Smart Battery Refer to Spare Smart Battery Pack for smart battery instructions for the Omni 5xxx terminal on the Omni 5xxx terminal. NOTE The smart battery pack must be installed and holding a minimum of a 1% charge to operate the Omni 5xxx terminal. Smart Battery Installation The smart battery installs in a slot on the back of the terminal, as shown in Figure 15. The locking tab clicks when the battery is in place. The slot is keyed, so that there is only one way to insert the battery. L T E T I A F O N N E A R I F F I D E N V O Smart Battery Charging C Figure 15 Install the Smart Battery Smart Battery Removal To remove the smart battery, press the locking tab at the top of the battery and pull the smart battery from its slot. On initial use, the smart battery must be fully charged and fully discharged through normal operation. After unpacking your Omni 5xxx terminal, install the battery and connect the power pack to the unit for 24 hours. Disconnect the power pack and allow your Omni 5xxx terminal to remain on until the smart battery completely discharges. Reconnect the power pack to the unit and allow the smart battery to recharge a maximum of 24 hours. It is also recommended that the smart battery receive a periodic full discharge. To ensure a full discharge, use the unit until the battery is fully drained. R To determine the charge state of the battery, push the test button icon (shown in Figure 16) on the bottom of the battery. The bar LED status indicators on the battery each indicate 25% of the charge state. When the battery charge state reaches 10%, the LED (Figure 16) blinks, indicating a low-charge state. The battery charge state displays at the bottom of the first copyright screen when the terminal is turned on. NOTE Conserve battery power by turning the Omni 5xxx terminal off when not in use. If the terminal is not to be used for several days, remove the battery from the terminal as it continues to discharge even when the terminal is turned off. 24 OMNI 5XXX INSTALLATION GUIDE TERMINAL SETUP Install/Replace SIM Card (GSM models) The smart battery has a safety circuit to protect the Li-ion cells from overcharging and over-discharging. If the battery is over-discharged, the safety circuit shuts down the battery and none of the indicator LEDs (see Figure 16) on the battery pack blink. The battery must then be recharged to restore operation. NOTE The Omni 5xxx terminal automatically shuts off when the smart battery reaches the critically low charge state. If this occurs, the smart battery must recharge a minimum of 1/2 hour before it can power the terminal. It make take several recharge attempts to reset the safety circuit when charging a smart battery that has reached a critically low charge state. If the Omni 5xxx terminal is already running an application (for example, SoftPay), a battery status indicator may appear on the display. R I F F I D BATTERY CHARGE STATE TEST BUTTON AND STATUS INDICATOR LEDS L T N N A E T I A F O E R Figure 16 Smart Battery Charge Indicator LEDs and Test Button To ensure that you get the longest possible performance from the smart battery, it must be allowed to fully discharge periodically. The smart battery can be charged and discharged hundreds of times, but will eventually wear out. When operating times are noticeably shorter than usual, it is time to buy a new battery (see Accessories and Documentation for ordering information). WARNING Do not dispose of batteries in a fire. Li-ion batteries must be recycled or disposed of properly. Do not dispose of Li-ion batteries in municipal waste sites. Install/Replace SIM Card (GSM models) The SIM (Subscriber Identity Module) card is a smart card inserted in the Omni 5xxx GSM terminal that contains your GSM radio account information. Use the following procedure to replace or install a SIM card. Smart Battery Life E N V O C 1 Remove screw from SIM card access door on back of Omni 5xxx terminal
(Figure 17). Figure 17 Remove SIM Door Screw OMNI 5XXX INSTALLATION GUIDE 25 TERMINAL SETUP Wireless Transactions 2 Remove the SIM card access door (Figure 18):
Figure 18 3 Open the SIM card holder and slide the SIM card supplied by your provider Slide Off SIM Card Access Door into the cardholder (Figure 19). Do not lose the SIM card dust cover or retaining screw. R I F F I D NOTE V O NOTE E N C L T E T I A F N N A O E R Figure 19 Insert SIM Card into Cardholder The SIM cardholder has a notch on one corner to ensure the SIM card is positioned correctly. The SIM card has a notch on one corner for easy orientation in the cardholder. Before inserting the SIM card, position it as shown in Figure 19, with the cards gold contacts facing down. Wireless Transactions 4 Replace the SIM card access door and screw. To conduct a wireless transaction:
Ensure the terminal is in an optimal position for transmitting. Follow the on-screen instructions provided with your application. Smart Card Transaction The smart card transaction procedure may vary from one application to an another. Verify the procedure with your application provider before you perform a smart card transaction. To Conduct a Smart Card Transaction 1 Position a smart card with the contacts facing upward (see Figure 20). 2 Insert it into the smart card reader slot in a smooth, continuous motion until it seats firmly. 26 OMNI 5XXX INSTALLATION GUIDE
TERMINAL SETUP Magnetic Card Reader Use 3 Remove the card only when the application indicates the transaction is complete. R I F F I D E N CAUTION V O Magnetic Card Reader Use C To Conduct a Credit/
Debit Card Transaction keypad. L T N N A E T I A F O E R Figure 20 Inserting a Smart Card Leave the smart card in the card reader until the transaction is complete. Premature card removal will invalidate the transaction. The Omni 5xxx supports credit/debit card transactions. 1 Position a magnetic card with the stripe facing down and in, toward the 2 To ensure a proper read of the magnetic swipe card, the user should insert the magnetic card from the top of the unit, as shown in Figure 21. OMNI 5XXX INSTALLATION GUIDE 27 TERMINAL SETUP Antenna (Some Wireless Models) 3 Swipe the card through the magnetic card reader. E N V O NOTE CAUTION C Figure 21 Using the Magnetic Card Reader Antenna (Some Wireless Models) For some Omni 5xxx terminals to establish a wireless connection, an external antenna is provided. This connection allows communication with your service provider to upload transaction data from the terminal and download system upgrades to the terminal. Radio service is activated by your service provider. R I F F I D L T N N A E T I A F O E R Some Omni 5xxx terminals have an internal antenna and this section can be ignored. Only use the antenna designed for your unit. Failure to use the proper antenna results in the inability to establish a wireless connection. Never hold the unit by the antenna; doing so may break the connection and void your warranty. This section only discusses Omni 5xxx terminals with external antenna. Installation The Omni 5xxx should arrive from manufacture with the antenna attached. If unattached, use the following procedure to install the antenna:
1 Locate the antenna port on the back side of the Omni 5xxx terminal. 2 Align the connector on the end of the antenna with the connector on the end of the terminal. 28 OMNI 5XXX INSTALLATION GUIDE TERMINAL SETUP Antenna (Some Wireless Models) 3 Push gently on the center of the base of the antenna until it slides into position. 4 Screw the barrel nut finger tight to retain the antenna. Orientation To establish good wireless communication (uplink), vertically align the antenna always with respect to ground and sky. For example, if standing and holding the terminal horizontally, position the antenna at an approximately 90 angle to the unit (that is, pointing up from the printer). This should point the antenna directly at the sky. If the unit is on a flat surface (for example, a table top) position the antenna so that it points directly at the sky. If an application (for example, SoftPay) is installed in your Omni 5xxx unit, a signal strength indicator may appear on the display. E NOTE V O C N Replace the Antenna R I F F I D position. end of the terminal. O E R L T N N A E T I A F If your Omni 5xxx terminal has difficulties completing wireless transactions, you may have to replace the antenna. Use the following procedure to replace the antenna:
1 Remove the existing antenna from the Omni 5xxx terminal:
a Unscrew the barrel nut to loosen the antenna. b Pull gently on the center of the base of the antenna until it slides out of 2 Align the connector on the end of the new antenna with the connector on the 3 Push gently on the center of the base of the antenna until it slides into position. 4 Screw the barrel nut finger tight to retain the antenna. OMNI 5XXX INSTALLATION GUIDE 29 TERMINAL SETUP Antenna (Some Wireless Models) R I F F I D E N V O C L T N N A E T I A F O E R 30 OMNI 5XXX INSTALLATION GUIDE CHAPTER 3 Specifications This chapter discusses power requirements, dimensions, and other specifications of the Omni 5xxx terminal. Power Omni 5xxx terminal: 9 V DC; 4 A DC Power Pack UL, ITE listed, Class 2 power supply Input rated: 100 - 240V AC, 50/60 Hz Output rated: 8.6 - 9.4V DC 4.0 A Barrel connector polarity:
L T N N A E T I A F R I F F I D O E R External Dimensions Length: 209.2 mm (8.2 in)
Width: 101.8 mm (4.0 in) Depth: 72 mm (2.8 in) Weight Terminal unit weight: 0.48kg (1.06 lb) Temperature Operating temperature: 0 to 40 C (32 to 104 F) Storage temperature: -30 to + 60 C (-22 to 140 F) Relative humidity: 5% to 90%; no condensation E N V O C NOTE CDMA SAR compliance for body worn operating configurations is limited to the specific belt clips / holsters / accessories that have no metallic component in the assembly. The highest reported SAR values for Omni 5xxx terminals under the FCC ID B32OMNI5600C are: PMS modes (Part 22) - Body-worn 0.567mW/g, PCS modes
(Part 24) - Body-worn 0.205mW/g. GSM/GPRS SAR compliance for body worn operating configurations is limited to the specific belt clips / holsters / accessories that have no metallic component in the assembly. The highest reported SAR values for Omni 5xxx terminals under the FCC ID B32OMNI5600G are: PMS modes (Part 22) - Body-worn 0.753 mW/g, PCS modes (Part 24) - Body-worn 0.564mW/g. OMNI 5XXX INSTALLATION GUIDE 31
SPECIFICATIONS Weight R I F F I D E N V O C L T N N A E T I A F O E R 32 OMNI 5XXX INSTALLATION GUIDE Maintenance Clean the Terminal CAUTION CHAPTER 4 The Omni 5xxx has no user-maintainable parts. To clean the terminal, use a clean cloth slightly dampened with water and a drop or two of mild soap. For stubborn stains, use alcohol or an alcohol-based cleaner. Never use thinner, trichloroethylene, or ketone-based solvents they may deteriorate plastic or rubber parts. Do not spray cleaners or other solutions directly onto the keypad or terminal display. L T N N A E T I A F R I F F I D O E R Teminal Contacts Gently swab the contacts with alcohol or contact cleaner to remove dirt. It is important that the exposed contacts for the battery stay clean and unbent. CAUTION Avoid touching the contacts in the raised area in the center of the battery and the recessed area on the terminal. Finger oils tarnish contacts, causing bad connections. If the battery charge state or terminal power LEDs do not light when the terminal is connected to the power supply or there is a high occurrence of bad or incomplete data transfers, clean the contacts. Card Readers The magnetic and smart card readers require no regular maintenance. For card reader service, contact your VeriFone distributor or service provider. E N V O C CAUTION Do not attempt to clean the card readers. Doing so may void your warranty. OMNI 5XXX INSTALLATION GUIDE 33 MAINTENANCE Card Readers R I F F I D E N V O C L T N N A E T I A F O E R 34 OMNI 5XXX INSTALLATION GUIDE CHAPTER 5 VeriFone Service and Support For Omni 5xxx terminal problems, contact your local VeriFone representative or service provider. Return a Terminal or Smart Battery for Service V O NOTE C E N International customers, please contact your local VeriFone representative for assistance with your service, return, or replacement. For Omni 5xxx product service and repair information:
USA VeriFone Service and Support Group, 1-800-VeriFone (837-4366), Monday - Friday, 8 A.M. - 8 P.M., Eastern time International Contact your VeriFone representative Before returning a Omni 5xxx terminal or smart battery to VeriFone, you must obtain an MRA number. The following procedure describes how to return one or more Omni 5xxx terminals for repair or replacement (U.S. customers only). L T N N A E T I A F R I F F I D O E R 1 Gather the following information from the printed labels (see Figure 22 and Figure 23) on each Omni 5xxx terminal or smart battery to be returned:
Product ID, including the model and part number. For example, OMNI 5100 and Pxxx- xxx-xx Serial number (S/N xxx-xxx-xxx) 2 Obtain MRA number(s) by completing one of the following:
a Call VeriFone toll-free within the United States at 1-800-VeriFone and follow the automated menu options. Select the MRA option from the automated message. The MRA department is open MondayFriday, 8 A.M.8 P.M., Eastern time. Give the MRA representative the information gathered in Step 1. If the list of serial numbers is long, you can fax the list, along with the information gathered in Step 1, to the MRA department at 727-953-
4172 (U.S.). b Address a fax to VeriFone MRA Dept. with the model and part number(s) Include a telephone number where you can be reached and your fax number. OMNI 5XXX INSTALLATION GUIDE 35
VERIFONE SERVICE AND SUPPORT Return a Terminal or Smart Battery for Service c Complete the Inquiry Contact Form at http://www.verifone.com/assistance/
pos_assist.cfm. Address the Subject box with to VeriFone MRA Dept. Reference the model and part number in the Note box. NOTE One MRA number must be issued for each Omni 5xxx terminal you return to VeriFone, even if you are returning several of the same model. 3 Describe the problem(s). 4 Provide the shipping address where the repaired or replacement unit must be returned. R I F F I D 5 Keep a record of the following items:
Assigned MRA number(s). VeriFone serial number assigned to the Omni 5xxx terminal or smart battery you are returning for service or repair (terminal serial numbers are located on the bottom of the unit (see Figure 22); smart battery serial numbers on the side of the battery (see Figure 23)). Shipping documentation, such as air bill numbers used to trace the shipment. Model(s) returned (model numbers are located on the VeriFone label on the bottom of the Omni 5xxx terminal). L T E T I A F N N A O E R PART NUMBER E N V O C SERIAL NUMBER Figure 22 Information Label on Terminal (Bottom View) 36 OMNI 5XXX INSTALLATION GUIDE
VERIFONE SERVICE AND SUPPORT Accessories and Documentation L R I F F I D SERIAL NUMBER LABEL PRODUCT INFORMATION LABEL N N A E T I A F T O E R E N V O Accessories and Documentation C Power Pack Thermal Printer Paper Figure 23 Smart Battery Information Label Locations VeriFone produces the following accessories and documentation for the Omni 5xxx terminal. When ordering, please refer to the part number in the left column. VeriFone online store at www.store.verifone.com USA VeriFone Customer Development Center, 800-VeriFone (837-4366), Monday - Friday, 7 A.M. - 8 P.M., Eastern time International Contact your VeriFone representative Contact your local VeriFone distributor to determine which power pack or power cord fits your needs. CPS10936-3A DC power pack (universal) 21973-01 AC power cord (US) CRM0039-01 CRM0039 in 30-roll bulk package CRM0040 High-grade thermal printer paper, 57 mm (2.24-inch) width, 25-meter (82-feet) length; single roll; Available in 20-roll or 50-roll bulk packages VeriFone Cleaning Kit 02746-01 Cleaning Kit Telephone Line Cord 00124-17 2.1-meter (7-foot) telephone line cord, black, with modular RJ11-type connectors OMNI 5XXX INSTALLATION GUIDE 37
VERIFONE SERVICE AND SUPPORT Accessories and Documentation Swivel Stand 23050-01 Swivel Stand Documentation 23219 23218 23217 23230 23231 Omni 5xxx Quick Installation Guide Omni 5xxx Certifications and Regulations Omni 5xxx Reference Manual Verix V Operating System Programmers Manual Verix V Tools Programmers Manual R I F F I D E N V O C L T N N A E T I A F O E R 38 OMNI 5XXX INSTALLATION GUIDE Troubleshooting Guidelines CHAPTER 6 The troubleshooting guidelines provided in the following section are included to assist you to successfully install and configure your Omni 5xxx terminal. If you have problems operating your Omni 5xxx terminal, please read through these troubleshooting examples. If the problem persists even after performing the outlined guidelines or if the problem is not described below, contact your local VeriFone representative for assistance. Typical examples of malfunction you may encounter while operating your Omni 5xxx terminal and steps you can take to resolve them are listed. The Omni 5xxx terminal comes equipped with tamper-evident labels. The Omni 5xxx contains no user serviceable parts. Do not, under any circumstance, attempt to disassemble the terminal. Perform only those adjustments or repairs specified in this guide. For all other services, contact your local VeriFone service provider. Service conducted by parties other than authorized VeriFone representatives may void any warranty. E R I F F I D L T E T I A F Using an incorrectly rated power supply may damage the terminal or cause it not to work as specified. Before troubleshooting, ensure that the power supply being used to power the terminal matches the requirements specified on the bottom of the terminal. (See Chapter 3, Specifications, for detailed power supply specifications.) Obtain the appropriately rated power supply before continuing with troubleshooting. O E R N N A NOTE V O CAUTION C N Terminal Does Not Start Terminal Display Does not Show Correct/
Readable Info Smart Battery Will Not Charge Ensure that the smart battery charge state is not below the critically low level. Recharge or replace the smart battery. Ensure that you pressed the ENTER/ON key for approximately 3 seconds, until the unit lit up. Recharge or replace the battery. Connect the Omni 5xxx terminal in to a known-good power supply (if you have one) to see if this clears the problem, which points to a discharged battery. If the problem persists, contact your local VeriFone representative for assistance. The smart battery must initially receive a full charge and then full discharge to calibrate its full charge capacity. This operation is performed at manufacture;
however, it is recommended that the battery receive a full charge/discharge once a year. OMNI 5XXX INSTALLATION GUIDE 39
TROUBLESHOOTING GUIDELINES Blank Display NOTE Allow the Omni 5xxx terminal to remain connected to the power pack for a minimum of 2 hours, maximum of 4 hours to ensure the battery receives a full charge. Conserve battery power by turning the Omni 5xxx terminal off when not in use. If the terminal is not to be used for several days, remove the battery from the terminal as it continues to discharge even when the terminal is turned off. To discharge the smart battery, run the unit until the smart battery is fully drained. Blank Display When the Omni 5xxx terminal display screen does not show correct or clearly NOTE The Omni 5xxx terminal automatically shuts off when the smart battery reaches the critically low charge state. If this occurs, the smart battery must recharge a minimum of 1/2 hour before it can power the terminal. It make take several recharge attempts to reset the safety circuit when charging a smart battery that has reached a critically low charge state. L R I F F I D readable information:
Check terminal power connection. Remove and reapply power to the terminal. Check all cable connections and verify that the telephone line is properly connected. If the problem persists, contact your local VeriFone service provider. N N A E T I A F T O E R Check that the telephone line is working by plugging it into a working telephone and listening for a dial tone. Replace the telephone cable that connects the terminal with a cable you know is working correctly. E N V O C Terminal Does Not Dial Out If the terminal does not dial out:
Check the telephone line connections. Printer Does Not Print If the problem persists, contact your local VeriFone service provider. If the printer does not work properly:
Check battery status or terminal power connection. The printer will not print if there is an insufficient charge remaining in the battery to complete the print operation. Check if the printer is out of paper and that the roll is properly installed. Open the paper roll cover and install a new roll of printer paper or ensure that the roll is feeding from the bottom. Verify that the printer roller and paper roll dust cover are properly installed. If the problem persists, contact your VeriFone distributor or service provider. 40 OMNI 5XXX INSTALLATION GUIDE
TROUBLESHOOTING GUIDELINES Printer Paper Jam Printer Paper Jam If paper jams inside the printer:
Press the button on the side of the terminal to unlatch the paper roll cover, then open the cover. Remove the damaged paper from the paper roll and clear the feed mechanism. Install a roll of printer paper, as described in Install Paper Roll. WARNING Peripheral Device Does Not Work If the problem persists, it may be due to poor paper quality. Install a new roll of higher-quality paper. Poor-quality paper may jam the printer. To order high-quality VeriFone paper, refer to Accessories and Documentation. If any peripheral device (PIN pad or smart card reader) does not work properly:
Check the power cord connection to the peripheral device. Check that the device connected to the proper port has power and is functioning properly. If possible, perform a self-test on the device in question. The cable connecting the optional device to the Omni 5xxx terminal serial port may be defective. Try a different serial cable. See Connect Optional Device(s). If the problem persists, contact your local VeriFone representative. R I F F I D L T E T I A F Check the terminal display. If it displays the wrong character or nothing at all when you press a key, follow the steps outlined in Transactions Fail To Process. If pressing a function key does not perform the expected action, refer to the user documentation for that application to ensure you are entering data correctly. O E R N N A E N V O Keypad Does Not Respond If the keypad does not respond properly:
C If the problem persists, contact your local VeriFone representative. Transactions Fail To Process There are several reasons why the terminal may not be processing transactions. Use the following steps to troubleshoot failures. Check Magnetic Card Reader Perform a test transaction using one or more different magnetic stripe cards to ensure the problem is not a defective card. Ensure that you are swiping cards properly. With the Omni 5xxx card reader, the black magnetic stripe on the card should face down and in toward the keypad and be inserted from the top of the terminal (see Figure 21). Process a transaction manually, using the keypad instead of the card reader. If the manual transaction works, the problem may be a defective card reader. OMNI 5XXX INSTALLATION GUIDE 41
TROUBLESHOOTING GUIDELINES Transactions Fail To Process Contact your VeriFone distributor or service provider. If the manual transaction does not work, proceed to Check Telephone Line. Check Smart Card Reader Perform a test transaction using several different smart cards to ensure the problem is not a defective card. Ensure that the card is inserted correctly and that the card is not removed prematurely. Ensure the MSAM cards are properly inserted in the cardholders and that the cardholders are properly secured (see Install/Replace MSAM Cards). Contact your VeriFone distributor or service provider. If the manual transaction does not process, proceed to Check Telephone Line. Check Telephone Line R I F F I D Disconnect the telephone line from the bottom of the Omni 5xxx terminal and connect it to a working telephone to check for a dial tone. If there is no dial tone, replace the telephone cable. If the problem appears to be with the telephone line, check with the party you are trying to call to see if their system is operational. If they are not experiencing difficulties with their line, contact the telephone company and have your line checked. If the telephone line works, contact your local VeriFone representative for assistance. L T N N A E T I A F O E R E N V O C 42 OMNI 5XXX INSTALLATION GUIDE
VeriFone, Inc. 2455 Augustine Drive Santa Clara CA 95054-3002 Tel: (800) VeriFone (837-4366) www.verifone.com L T N N A E T I A F R I F F I D O E R E N V O C Omni 5xxx Installation Guide VeriFone Part Number 23216, Revision A.1
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2004-08-31 | 1850.2 ~ 1909.8 | PCB - PCS Licensed Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2004-08-31
|
||||
1 | Applicant's complete, legal business name |
VeriFone Inc
|
||||
1 | FCC Registration Number (FRN) |
0022825988
|
||||
1 | Physical Address |
88 West Plumeria Drive
|
||||
1 |
San Jose, California 95134
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
j******@baclcorp.com
|
||||
1 | TCB Scope |
B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
B32
|
||||
1 | Equipment Product Code |
OMNI56XXG
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
D**** P****
|
||||
1 | Title |
Director, Engineering
|
||||
1 | Telephone Number |
916-6********
|
||||
1 | Fax Number |
916-6********
|
||||
1 |
D******@verifone.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | PCB - PCS Licensed Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Wireless POS Terminal | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | This transmitter operates with a specific hand-held terminal and has been tested for SAR compliance at 0 cm from the antenna for mobile and hand-held configurations. Users must be informed of the operating requirements for satisfying RF exposure compliance. The highest reported SAR value is 0.753 mW/g at 100% duty factor. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Bay Area Compliance Laboratory Corp.
|
||||
1 | Name |
J****** C****
|
||||
1 | Telephone Number |
40873********
|
||||
1 | Fax Number |
40873********
|
||||
1 |
J******@baclcorp.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 24E | 1850.2 | 1909.8 | 0.962 | 2.5 ppm | 310KGXW | ||||||||||||||||||||||||||||||||||
1 | 2 | 22H | 824.2 | 848.8 | 1.919 | 2.5 ppm | 310KGXW |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC