Operation Manual 2GIG-Z-BRG1-433 Z-Wave Bridge 433MHz Federal Communications Commission Statement This equipment has been followed to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interferene by one of the following measures:
Reorient or relocate the receiving antenna, Increase the separation between the equipment and receiver, Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undersired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate this equipment. Limited Warranty Vision Guarantees that every wireless lighting module is free from physical defects in material and workmanship under normal use for one year from the date of purchase. If the product proves defective during this one-year warranty period, Vision will replace it free of charge. Vision does not issue any refunds. This warranty is extended to the original end user purchase only and is not transferable. This warranty does not apply to : (1) damage to units caused by accident, dropping or abuse in handling, or any negligent use; (2) units which have been subject to unauthorized repair, taken apart, or otherwise modified; (3) units not used in accordance with instruction; (4) damages exceeding the cost of the product; (5) transit damage, initial installation costs, removal cost, or reinstallation cost. For information on addional devices, plesae visit us at www.visionsecurity.com.tw 2GIG-Z-BRG1-433 V0 1011218
-3-
Introduction Thanks for choosing the Visions CT Clamp Bridge of the home automation device. This module is a Z-WaveTM enabled device (interoperable, two-way RF mesh networking technology) and is fully compatible with any Z-WaveTM enabled network. Every main powered Z-WaveTM enabled device acts as a signal repeater and multiple devices result in more possible transmission routes which helps eliminate RF dead-sport. Z-WaveTM enabled devices displaying the Z-WaveTM logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturers Z-WaveTM enabled networks. This module will receive the most update energy usage from CT Clamp, and send to the controller by its signal. This module will also send dimmer signal to the appliance that attached to this module by receiving Z-WaveTM signal from controller or manually switch. With special design, this module wont interfere the other power outlet when plug into the AC outlet. This module also acts as repeater
(supporting FLiRS). Product Description and Specification
* For indoor use *
Specification:
Protocol: Z-WaveTM (ZM3102N) Frequency Range:
908.42MHz (2GIG-Z-BRG1-433) Operating Range: Up to 100 feet line of sight Package Content:
1pc 2GIG-Z-BRG1-433
(CT Clamp Bridge) 1pc User Manual
~140
(5
~ 60 Operating Temp.: -15 Operating Voltage: 120V~, 15A, 60Hz For 2GIG-Z-BRG1-433 only Max. Load: 300W for Resistive Load
-1-
C C F F Z-Wave COMMAND_CLASS_SWITCH_MULTILEVEL Command Class:
(Mapping COMMAND_CLASS_BASIC) COMMAND_CLASS_SWITCH_ALL COMMAND_CLASS_METER_V2 COMMAND_CLASS_PROTECTION COMMAND_CLASS_VERSION COMMAND_CLASS_MANUFACTURER_SPECIFIC Operation If you are installing the entire Z-WaveTM system for the first time, please refer to the installation guide of Z-WaveTM Interface Controller before installing 2GIG-Z-BRG1-433. 1. Learning CT Clamp: Press program button before power on and green LED will flash 3 times, release the button till the green LED stay on. Switch on the CT Clamp. LED shall go off after learning. 2. For Inclusion in (adding to) a network: Put the Z-WaveTM Interface Controller into inclusion mode, and following its instruction to add the 2GIG-Z-BRG1-433 into your controller. To get in the Inclusion mode, the distance between 2GIG-Z-BRG1-433 and controller is suggested to be in one meter. User can press program switch once to be included. For Exclusion from (removing from) a network: Set up the Z-WaveTM Interface Controller into exclusion mode, and following its instruction to delete the 2GIG-Z-BRG1-433 from your controller. Press program button to be excluded. 3. 2GIG-Z-BRG1-433 will store the latest energy usage (W & kWh) from CT Clamp, and send to controller if the controller is asking for information. 4. Manually turn the connected lighting On/Off by your controller or pressing the program button. This is toggle switch. If the light is Off, pressing the button turns the light On and vice versa. User can also adjust the brightness level of the connected lighting by your controller or pressing and holding the program button. Release the button when the desired level is attained. This is toggle function. The lighting will dim until the minimum level is attained or the button is released. The next time the button is pressed and held, the level will increase until the maximum level is attained or the button is released. 5. Protection Function: User can use the Protection command class to disable the Program Switch.
(1) Protection State=0x00 (Unprotected, Program Switch acts as normal);
(2) Protection State=0x01 (Protection by sequence, user can manual turn the appliance on/off by press Program Switch 3 times, instead of 1 time);
(3) Protection State=0x02 (No operation possible, temporarily turn the Program Switch function off).
-2-
Industry Canada Notice Operation is subject to the following two conditions: (1) this device may not cause interference and (2) this device must accept any interference, including interference that may cause undesired operation of the device.