OPZ1ZT92
ZETA Light Sensor
1
OPZ1ZT92
Copyright Statement
ZiFiSense owns the copyright on this specification. No part of
this specification may be reproduced in any form or means,
without the prior written consent of ZiFiSense.
Disclaimer
This specification is preliminary and is subject to change at any
time without prior notice. ZiFiSense assumes no responsibility
for any errors contained herein. ZiFiSense is not responsible for
any patent infringement of third party on its use or as a result
of its uses. Other products/services not certified by the patent
license, shall be deemed within patent ownership of ZiFiSense.
2
Table of Contents
OPZ1ZT92
1. Product Description...............................................................................................................................4
2. Applications........................................................................................................................................... 4
3. Features................................................................................................................................................. 4
4. Specifications.................................................................................................................................... 5
5. Packing List........................................................................................................................................ 5
6. Installation.......................................................................................................................................... 6
6.1. Screw........................................................................................................................................ 6
6.2. Adhesive 3M.......................................................................................................................... 8
7
6.3. Cable Ties.............................................................................................................................. 9
. Use of Device................................................................................................................................... 12
8.1. Steps for usage....................................................................................................................... 12
8.2. Support function.................................................................................................................. 12
8. Common faults and handling...................................................................................................... 13
3
1. Product Description
OPZ1ZT92
ZETA Light Sensor is a low power illuminance detect sensor which is able
to quantify the illuminance value and provide alarm signals if the
threshold values are exceeded.
2. Applications
Room lighting detection, lamp aging detection
3. Features
Wireless transmission
Battery-powered, low power consumption
Easy to install, high sensitivity
Reliable detection
Real-time transmission
4
4. Specifications
OPZ1ZT92
Product No.
OPZ1ZT92
Transmission protocol
ZETA
Wireless Features
Frequency band
Output power
Sub-GHz, adjustable according to
local regulations
20dBm max, adjustable according
to local regulations
Electrical Features
Power supply
Battery, 2*ER14505
Battery capacity
2*2700 mAh
Stand-by current
≤ 10 μA
Working current
≤ 70 mA
Size
66*55*36 mm
Physical Features
Enclosure material
Waterproof level
ABS
IP30
Antenna
Range
External glue stick antenna
0.1~2000 lux
Precision
3% *reading + 0.5% *range
℃
℃
Operating temperature
℃
-20
~+75
℃
Storage temperature
-30
~+85
Sensor
Characteristics
Working
Environment
5. Packing List
Light Sensor
Battery (ER14505)
1
2
5
6. Installation
OPZ1ZT92
There are three installation methods: Screw, 3M Adhesive and cable ties.
6.1. Screw
6.1.1.Auxiliary material
No. Materials
1
2
self tapping screw (M3*20)
#4 expanded plastic pipe
,
,
3
4
Percussion drill
#4 drill bit
hammer
slotted screwdriver, cross screwdriver
6.1.2.Installation instructions
Use a slotted screwdriver to open the top cover from the bottom edge.
Open the device case
Quantity
2/device
2
1
1
opening
Place the device in the mounting position, punch and insert the expanded
plastic pipe.
Punching
Fixation
6
OPZ1ZT92
Use the self-tapping screws to secure the device in the mounting position.
mounting hole
mounting hole
Power on
Insert the power plug into the upper power socket, install two 14505
batteries (remove the insulation sheet for the existing battery), and close
the upper cover.
power socket
7
6.2. Adhesive 3M
6.2.1.Auxiliary material
OPZ1ZT92
No. Materials
Quantity
3M seamless thickened double-sided adhesive
5CM
Slotted screwdriver, utility knife
2
1
2
6.2.2.Installation instructions
Installation position
Select a flat mounting position, and clean it up.
Open the device case
Use a slotted screwdriver to open the top cover from the bottom edge.
opening
Power on
Insert the power plug into the upper power socket, install two 14505
batteries (remove the insulation sheet for the existing battery), and close
the upper cover.
8
OPZ1ZT92
power socket
Adhesive device
Take the appropriate amount of 3M adhesive, attach it to the back of the
sensor, remove the protective film of the 3M adhesive, and install the
device to the specified position.
6.3. Cable Ties
6.3.1.Auxiliary material
No. Materials
(
1
2
Metal cable ties
5*300mm)
Slotted screwdriver, utility knife
6.3.2.Installation instructions
Quantity
2
Open the device case
Use a slotted screwdriver to open the top cover from the bottom edge.
9
OPZ1ZT92
opening
Fixation
Pass the 2 cable ties through the device and secure to the installation rod
Installation position
10
OPZ1ZT92
Power on
Insert the power plug into the upper power socket, install two 14505
batteries (remove the insulation sheet for the existing battery), and close
the upper cover.
power socket
11
7. Use of Device
7.1. Steps for usage
OPZ1ZT92
Place the device within the coverage of the ZETA network
Install the battery, and wait for the device to go online.
After the device is online, the current device status is reported.
According to the usage scenario, set the policy configuration such as
alarm enable status and alarm threshold.
Daily maintenance and data viewing.
7.2. Support function
Version number: Report the software version number of the sensor
only once after power-on.
Status report: Report status data periodically according to the setting.
Set/Query report heartbeat period: can set or query the heartbeat
report cycle. (Range: 1~65535 min, default: 2*60min)
Set/Query report alarm period: When the detected temperature and
humidity exceeds the set threshold, the alarm will be reported on the
set period. (Range: 0-255 minutes, default value: 0, which means the
alarm is reported only once.)
Set/Query Alarm Threshold: Set the upper lower alarm threshold for
alarms. Once the detected value exceeds the set alarm threshold, the
device will report the alarm immediately. (Range: 0-1677721.4, unit
0.1lux, value is 0xFF 0xFF 0xFF means no such threshold is set, please
note that the lower threshold should be lower than the upper
threshold during setting)
Set/Query the alarm release threshold: Avoid repeated alarms caused
by fluctuations of the detected value. Generally, the default value is
used, and no setting is required.
Set/Query alarm enable: Enable ON means that the alarm status needs
to be reported when the threshold is exceeded. Enable Off means no
alarm is required even if the threshold is exceeded.
Set/Query acquisition period: The period of which the device collects
sensor information (range: 0-65535 seconds, when the value is 0, it
means real-time acquisition).
Query status: Actively query the current status of the device, including
12
OPZ1ZT92
current light intensity, alarm enable information.
Query version number: You can query the software version number of
the current sensor.
8. Common faults and handling
Ensure ZETA signal coverage
Ensure that the device is powered on, and the ZETA network device
management platform can observe that the ZETA module is on line
Check the battery usage of the device. When the battery is low, replace
the battery in time.
13
FCC WARNING
Any Changes expressly or modifications not approved by the party responsible for compliance
could void the user's authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause
undesired operation.
OPZ1ZT92
14