all | frequencies |
|
|
exhibits | applications |
---|---|---|---|---|---|
manuals |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Operating-Manual-1 | Users Manual | 2.92 MiB | ||||
1 |
|
Operating-Manual-2 | Users Manual | 2.92 MiB | ||||
1 | Attestation Statements | |||||||
1 | Cover Letter(s) | |||||||
1 | External Photos | |||||||
1 | Cover Letter(s) | |||||||
1 | ID Label/Location Info | |||||||
1 | Cover Letter(s) | |||||||
1 | Test Report | |||||||
1 | Test Setup Photos |
1 | Operating-Manual-1 | Users Manual | 2.92 MiB |
FM 144/430MHz DUAL BAND TRANSCEIVER FT-4XR FT-4XE Operating Manual Contents Contents ................................................ 2 About this manual ................................ 2 Introduction ........................................... 1 Quick Guide .......................................... 2 Controls & Connections ...................... 3 Transceiver ............................................ 3 Display ................................................... 5 The Keypad Functions ........................... 7 Preparation ............................................ 8 Installing the Antenna ............................ 8 Attaching the Belt Clip ........................... 8 Installing the Battery Pack .................... 8 Removing the Battery Pack ............. 8 Supplied Accessories and Options .... 9 Supplied Accessories ............................ 9 Available Options ................................... 9 Charging the Battery Pack ................... 9 Charging the Battery Pack using the Rapid Charger (SBH-22) ....................... 9 Operation ............................................. 10 Changing between VFO mode and Memory mode ...................................... 10 Selecting the Operating Band ............. 10 Tuning to a Frequency(Two ways) ...... 10 Changing the Frequency Step ("AUTO"
for normal operation) ...................... 11 Adjusting the squelch setting .............. 11 Transmission ........................................ 12 Changing the Transmission Power Level
................................................................12 Locking Keys and PTT switch ............. 13 Tone Calling (1750 Hz) ....................... 13 Using the Memory .............................. 14 Registering to Memory Channels ....... 15 Memory Recall ..................................... 15 Clearing Memories .............................. 16 Recalling the Home Channels ............ 16 Changing the Home Channel Frequency
................................................................16 Memory Channel Scanning ................. 17 Setting the Receive Operation When Scanning Stops .................................... 17 Using Memory Tag .............................. 18 Using Memory Bank ............................ 18 Scanning Function ............................. 18 VFO Scan ............................................. 18 Using Set Mode ................................... 19 Tables of Set Mode Operations .......... 19 Restoring to Defaults (Reset) / Setting the Preferred Operating Mode ........... 23 Specifications ..................................... 24 About this manual Reference icon symbols and conventions are used in this manual. Their meanings are described in the below chart. Symbols Description This icon indicates cautions and information that should be read. This icon indicates notes, tips and information that should be read. This icon indicates other pages containing relevant information. This icon indicates FT-4X Advance Manual on the YAESU Website containing relevant information. Introduction Thank you for purchasing this Yaesu product. FT-4XR/4XE is a handheld transceiver for operation in the 144 MHz and 430 MHz Amateur radio bands. Bridged Transless (BTL) amplifier provides One Full Watt of Audio in spite of small size. Two Quick Recall Keys (User Programmable) for Individual Preferences Lockout Capabilities for Keypad/PTT Lockout. Emergency Operation (Alarm and HOME channel display)equipped. r A variety of individual selective calling functions; such as tone squelch
(CTCSS) and DCS functions ........................................................... 20 r Large-capacity 200 memory channels ........................................... 14 r 3 home channels and 10 pairs of PMS memory channels ..................... 16 r Create mnemonic tags for memory channels and Home channel .. 18 r Automatic power off (APO) feature turns the transceiver OFF after a 19 r The cloning feature allows the memory and configuration data from one 23 r The VOX system provides automatic transmit/receive switching based on 19 preset time period ........................................................................... transceiver to be transferred to another FT-4XR/4XE. ................... voice ................................................................................................ We urge you to read this manual in its entirety, and also the Advance Manual
(available for download on the Yaesu website), to gain a full understanding of the amazing capability of the exciting new FT-4XR/FT-4XE Transceiver. 1 FT-4XR/FT-4XE Operating Manual Quick Guide Names and display of Controls PTT Switch MONI/T-CALL Switch Function Key PWR/VOL Knob Microphone
(Frequency up and down) Key
[BAND] Key Normal operation (VFO Mode) Operating Frequency VFO-A Mode S Meter / PO Meter
. until it clicks. Turning the Power ON Rotate the Adjusting the volume Rotate the Selecting the Operating Band Press the The operating frequency changes between the 144 MHz Band, the 430 MHz Band, and the FM Radio Broadcast Band. Tuning the frequency Press the Adjusting the squelch setting The squelch level may be adjusted to mute the background noise when no signal is or
. received. 1. Press the p r e s s t h e switch). 2. Press the
(Function key), then
( M O N I / T- C A L L or to adjust the squelch level.
* When the squelch level is increased, the noise is more likely to be silenced, but it may become more difficult to receive weak signals. 3. Press the PTT (
) switch to save the setting. Transmitting Signals z Transmitting Press the
, then speak into microphone. 2 FT-4XR/FT-4XE Operating Manual Transceiver Controls & Connections Strap Hole (
Antenna Jack(SMA) (
8) 8) 11) PTT Switch (
Press and hold the PTT switch to transmit, and release it to receive. In the Set mode, press the PTT switch to save the new setting and return to normal operation. Microphone (
11) MONI/T.CALL Switch USA/Asian version While pressing and holding the MONI/T.CALL Switch, the squelch is opened temporarily. Press the Function key, then press the MONI/
T.CALL Switch to adjust the squelch level. European version Press the MONI/T.CALL switch to activates the T-CALL(1750 Hz). 3 FT-4XR/FT-4XE Operating Manual Function Key (
19) Pressing the Function key activates the Secondary key function. Pressing and holding the Function key enters the Set mode. In the Set mode, pressing the Function key to determine the setting Battery pack(
9) PWR/VOL Knob Turn this control clockwise to turn the transceiver ON and to increase Counter-clockwise rotation into the click-stop will turn the transceiver the volume. OFF. Emergency Key Press and hold it for three seconds to enable the Emergency Alarm beep functions and display the Home channel frequecy (VHF). TX/BUSY Indicator Lamp This indicator glows green when the squelch opens, and it glows red during transmit. Speaker LCD (Liquid Crystal Display) The display shows frequecny and current operating condition. Keypad The functions of the keypad are described in detail on page 5. SP jack SP jack provides connection for an microphone. MIC jack MIC jack provides connection for microphone and clone cable. 4 FT-4XR/FT-4XE Operating Manual Display VFO-A/B Memery Channel Number Home Channel Display Memory Bank Frequency / Memory Tag / PAGER Set Mode Item S Meter Displays the received signal strength PO Meter Displays the transmit power level Icon Description Priority Memory Channel Memory channel registered as a skip memory Repeater Shift Direction Semi duplex Memory (a simultaneously) Appears when the tone encoder function. Appears when the tone squelch function. Appears when the DCS function. The battery condition is displayed in 4 steps. Full battery power Enough battery power Battery is depleted. Charge battery.
(When blinking) Charge battery immediately.
: Appears when a function key is pressed. TX Power Level Indicator (LOW/MID TX Power Selected) Icon TX Power Meter during transmission
(No display) Tx Power HIGH (5 W) MID (2 W) LOW (0.5 W) 14 14 18 21 20 10 7 12 5 FT-4XR/FT-4XE Operating Manual Icon Description Appears when the Dual Receive(DW) function is enabled. Appears when the APO (Automatic Power-Off) function is enabled. Appears when the bell function is enabled. Appears when the lock function is enabled. Appears when the Memory Bank function is enabled. Appears when the VOX (Voice Operated Transmit) function is enabled. 7 19 19 13 18 22 6 FT-4XR/FT-4XE Operating Manual Key Function
#BAND V/M P1 P2 1 2 ABC 3 DEF 4 GHI 5 JKL 6 MNO 7 PQRS 8 TUV 9 WXYZ 0 SET The Keypad Functions Primary Function (Press Key) VFO Memory Recall Inputting Memory Tag Activates the Secondary key function(
appears) Moves the cursor to the left. Secondary Function
(Press F +
Key) Deactivates the Secondary key function(
appears) Third Function
(Press and Hold for over one second) Enters the Set mode. Memory Offset Tuning PMS(Program Mem-
ory (Mode) Scan) P r o g r a m S c a n Setting Numbers*+
/@
Press and hold this key to complete the memory channel registration Dual Receive (DW) function Memory write mode Stores to the Home channel Recalls the Home channel Stores the Semi -Duplex transmit frequency Reverses the transmit and receive frequencies while working through a repeater appears) Activates the Sec-
ondary key func-
tion(
Switches the band control between VHF, UHF and FM RADIO Broadcast S w i t c h e s t h e frequency control between the VFO and Memory Sys-
tems Recalls the stored P1(Programmble key) setting Recalls the stored P2(Programmble key) setting Number 1 Recalls the stored memory channel Number 1 Number 2 Recalls the stored memory channel Number 3 Recalls the stored memory channel Number 2, or characters A, B, or C Number 3, or characters D, E, or F Number 4 Recalls the stored memory channel Number 4, characters G, H, or I Number 5 Recalls the stored memory channel Number 5, characters J, K, or L Number 6 Recalls the stored memory channel Number 7 Recalls the stored memory channel Number 8 Recalls the stored memory channel Number 9 Recalls the stored memory channel Number 6, or characters M, N,or O Number 7, or characters P, Q, R, or S Number 8, or charactersT, U, or V Number 9, or characters W, X, Y, or Z DTMF autodialer settting Number 0 Recalls the stored memory channel Number 0 Stores the P1(Programmble key) setting Stores the P2(Programmble key) setting Recalls the Weather broadcast channel bank Activates the ARTS feature Key Lock feature 7 FT-4XR/FT-4XE Operating Manual Hold the thick base of the antenna Supplied Screws Belt Clip Strap Hole for commercially available strap Preparation Installing the Antenna 1. Turn the antenna clockwise until it is secured. z Do not hold or twist the upper part of the antenna when installing or removing it. To do so may break the conductors inside the antenna. z Do not key the transmit without installing the antenna. The transmitter components may be damaged. z When using an antenna other than the one supplied, or connecting to an external antenna, ensure that the SWR is adjusted to 1.5 or lower. Attaching the Belt Clip 1. Attach the belt clip on the back of transceiver using the supplied screws (two). z Be sure to use the supplied screws when attaching the belt clip. If any other screws are used, the belt clip cannot be secured firmly to the battery pack and the transceiver may drop off together with the battery pack;
the transceiver and battery pack may fall off, causing injury, breakage and other damage. z Use a hand strap which can withstand the weight of the transceiver. If the hand strap is not strong enough, the it may break and the transceiver may fall, causing injury, breakage and other difficulty. Installing the Battery Pack 1. Referring to the figure at the right, insert the battery pack into the seals of the battery compartment on the back of the transceiver. 2. Push the battery pack in until the battery latch clicks securely. Removing the Battery Pack 1. Turn the transceiver OFF. While sliding the latch in the direction of the arrow, as shown in the illustration, slide the battery pack downward and out of the transceiver. 8 FT-4XR/FT-4XE Operating Manual
1 | Operating-Manual-2 | Users Manual | 2.92 MiB |
Supplied Accessories and Options Supplied Accessories Rechargeable Li-Ion Battery Pack (7.4V1,750mAh) SBR-28LI Battery Charger Rapid Charger Antenna Belt Clip Operating Manual (this manual) SBR-28LI Manual Warranty Card SAD-20B SBH-22 SRA-15 SHB-18 z Ensure that the name of the dealer from which the transceiver was purchased, and the date of purchase are indicated on the warranty card. z If any item is missing, contact the dealer from which the transceiver was purchased. Available Options Rechargeable Li-Ion Battery Pack (7.4V1,750mAh) SBR-28LI Battery Charger Rapid Charger VOX Earpiece Microphone SSM-512B Antenna Speaker Microphone SSM-16 Programming Cable SCU-35 Clone Cable SCU-36 Belt Clip SHB-18 SAD-20B SBH-22 SRA-15 Charging the Battery Pack Charging the Battery Pack using the Rapid Charger (SBH-22) Using the supplied AC Adapter (SAD-20B) and the supplied Rapid Charger, it takes about 3.5 hours* to charge the SBR-28LI battery pack fully.
*: Depending on the battery status, the charging time might be increased. 1. Turn the transceiver OFF to install the battery pack. 2. Referring to the figure at the right, connect the battery charger plugs. When the battery is being charged, rapid charger cradle indicator lights red. 3. When charging is completed, rapid charger cradle indicator will light green. AC Adapter SAD-20B Rapid Charger SBH-22 z The rapid charger indicator blinks red and the battery pack is not charged after a lapse of 10 or more hours, stop charging the battery pack immediately. The battery pack is presumed to be at the end of its service life, or defective. In this case, replace the battery pack with a new one. z Charge the battery pack within the temperature range from +5 C to +35 C (+41 F to +95 F). 9 FT-4XR/FT-4XE Operating Manual Approximate Operating Time and Remaining Charge Level Indication Approximate operating time for the transceiver with the fully charged lithium-Ion battery pack (SBR-28LI), and the indication of the remaining charge level of the battery is shown in the below table:
Frequency band Band in Use Charge Level Indication (Icon) 144 MHz band Approx. 9.0 hours 430 MHz band Approx. 8.0 hours FM Broadcast Band Approx. 12.0 hours Full battery power Enough battery power Battery is depleted. Charge battery.
( W h e n b l i n k i n g ) Charge battery imme-
diately. The battery charge level calculations are based on an operating cycle of: Transmitting 6 seconds (5 W):
Receiving 6 seconds (VOL Level 16): Stand By 48 seconds (RX SAVE 1:5) Operation Changing between VFO mode and Memory mode Press the [ V/M] key repeatedly to toggle the frequency control between the VFO-A mode, VFO-B mode and the Memory mode. Selecting the Operating Band 1. Press the [#BAND] key to select the desired frequency band. Frequency ranges for each frequency band are below:
144 MHz band 430 MHz band FM Broadcast Band FM broadcast band may be received signals in the VFO-B mode only. Tuning to a Frequency(Two ways) Press the [] key or [] key to tune the frequency. 2. By pressing the function key and then press the [] key or the [] key, the frequency will change in 1 MHz steps. Press the numeric keys to enter the frequency digits in order, beginning with the 100 MHz digit. 10 FT-4XR/FT-4XE Operating Manual When entering a frequency using the numeric keys, it may be canceled by pressing the PTT switch. Changing the Frequency Step ("AUTO" for normal operation) Pressing the [] key or [] key, the frequency step may be changed. Normally, the factory default setting will provide a good frequency step. Pressing and holding the Function key Pressing the key
(Selecting "37 STEP") Pressing the Function key
(Entering the Set mode) 1. Press the [] key or the [] key to select the desired frequency step. 2. Press the PTT switch to save the setting and return to normal operation. In the default setting, of the frequency step is set to AUTO, which automatically provides a suitable frequency step according to the frequency band. Adjusting the squelch setting The squelch level may be adjusted to mute the background noise when no signal is present. 1. Press the function key and then press the MONI/T-CALL switch. LVL (0-15) appear on the display. 2. Press the [] key or [] key to a level at which the background noise is muted. 3. Press the PTT switch to save the setting. z The default setting isLVL 2. z When the squelch level is increased, the noise is more likely to be silenced, but it may become more difficult to receive weak signals. 11 FT-4XR/FT-4XE Operating Manual Transmission 1. While pressing and holding the PTT switch, speak into the microphone. TX/BUSY indicator lights red during the transmission. If the PTT switch is pressed when a frequency other than the amateur ham radio band is selected, an alarm tone (beep) will be emitted and ERROR appears on the LCD, disabling transmission. 2. Release the PTT switch to return to receive mode. When receiving a signal, the TX/BUSY Indicator lights red. Changing the Transmission Power Level TX/BUSY lamp Microphone Pressing and holding the Function key Pressing the key
(Entering the Set mode) 1. Press the [] or [] to select one of the following
(Selecting "40 TX PWR") Pressing the Function key transmission power levels. TX PO Level Icon
(off) PO meter
(5W)*
(2.5)
(0.5) HIGH MID LOW
*The default setting. 2. Press the PTT switch to save the setting and return to the normal operation. The transmission power level may be set separately for each frequency band. 12 FT-4XR/FT-4XE Operating Manual Locking Keys and PTT switch 1. Press and hold the [6] key, LOCK is displayed icon appears on the LCD for one second, the on the LCD, and then the keys and PTT switch are locked. z The keys and the PTT switch may be selected to be locked using Set Mode 20). The default setting is the [LK KEY] (the keys are
[18 LOCK](
locked). z The [MONI/T-CALL] switch and the PWR/VOL knob cannot be locked. 2. Press the [6] (LOCK) switch again, UNLOCK will be displayed on the LCD, the keys and the PTT switch are unlocked. Tone Calling (1750 Hz) If your transceiver is FT-4X (European version), press and hold in the MONI/
T-CALL switch to generates the 1750 Hz burst tone to access the European repeater. The transmitter will automatically be activated, and the 1750 Hz audio tone will be superimposed on the carrier. Once the repeater has been accessed, release the MONI/T-CALL switch, and use the PTT switch to activate the transmitter thereafter. If needed, the FT-4XR (USA/Asian version), may be set to access repeaters which require a 1750 Hz burst tone by setting the MONI/T-CALL switch to serve as a Tone Call switch instead. To change the configuration of the MONI/T-CALL switch, use Set Mode [19 M/T-CL] (
20). 13 FT-4XR/FT-4XE Operating Manual Using the Memory The FT-4XR/XE transceiver incorporates Large-capacity memory channels that can register the operating frequency, communication mode, and other operational information. Each memory channel can store the following information. 200 Memory Channels 3 Home Channels 10 pairs PMS Memory channel Operating frequency Frequency steps TX output power Memory tag Repeater information Tone information DCS information Skip memory information 10 Memory Banks, labeled BANK 1 through BANK10 Each Memory Bank can be assigned up to 200 channels from the standard and PMS memory channels. Memory Channel Configuration of the Transceiver PMS memory channels Memory channels 200 channels
(10 sets) 0 0 2 9 9 1 4 3 2 1 0 1 U 0 1 L
/
9 0 U 9 0 L
/
4 U 4 L
/
3 U 3 L
/
2 U 2 L
/
1 U 1 L
/
Home channels
(3 channels) Memory banks
(10 banks) Up to 200 memory channels can be registered to each bank.
(One memory channel can be registered to several memory banks For additional details on the Skip Search Memory, PMS memory channel and Memory Bank, refer to the Advanced Manual which may be downloaded from the Yaesu website. CAUTIONS!
The information registered to memor y channels can be corrupted by incorrect operation, static electricity, or electrical noise. Also, it can be erased in the event of a failure or repair. Be sure to keep a record of the settings on paper. 14 FT-4XR/FT-4XE Operating Manual Registering to Memory Channels 1. Set the frequency and the communication mode to be registered to a memory channel. 2. Press and hold the [ V/M] key. A blank memory channel will be displayed auto-
matically. 3. Press the [] key or [] key to select the desired channel number. The channel numbers that do not contain memory data will blink on the LCD. 4. Input the memory tag Use the numeric keys to input the characters. If not inputting a Tag (label), proceed to step 5. Input Character Example: Press the [2] key repeatedly to toggle among the following available characters. 2 A B C a b c 2 Press the function key to move the cursor. Memory Channel Number 5. Press and hold the [ V/M]. The beep sounds and the memory is saved. Memory Recall 1. While operating in the VFO mode, press the [ V/M] key to enter the Memory mode. The memory channel most recently used appears on the LCD. 2. Press the [] or [] key to select the desired memory channel. When the transceiver is already set to the Memory mode, an easy way to recall a memory channel is to enter the memory channel number using the numeric keypad. 3. Press the [ V/M] key to exit the memory mode, and return to the normal operation. 15 FT-4XR/FT-4XE Operating Manual Press and hold the MONI/T.CALL key and the PTT switch simultaneously, while turning the radio ON to enter the preferred operating mode. In the preferred operating mode, press the [] key or [] key to select the
[5 M-ONLY], then press the function key to enter the Memory Channel Only mode. To cancel the Memory Channel Only mode, press the [] key or [] key to select the [5 M-ONLY], then press the function key again. Clearing Memories Pressing and holding the Function key Pressing the key Pressing the Function key
(Entering the Set mode) 1. Press the [] key or [] key to select the memory channel from which the
(Selecting "20 MEM DEL") data is to be cleared. 2. Press the function key. del OK appears on the LCD and the memory channel is cleared. 3. Press the PTT switch to save the setting and return to the normal operation. Data on memory channel One, and the Home channel may not be cleared. Recalling the Home Channels 1. Press the Function key, and then press the [P1]
key. H and the home channel frequency of the cur-
rently selected band appears on the LCD. 2. Press the Function key, and then press the [P1]
key to return to the previous frequency. Home channel indication While recalling the home channel, press the [BAND] key repeatedly to toggle the home channel between 430MHz band, FM broadcast band and 144MHz band. Changing the Home Channel Frequency 1. Set the frequency and the operating mode you want to store as a home channel. 2. Press and hold the [ V/M] key. A blank memory channel will be displayed automatically. 3. Press the [P1] key.
"HOM-IN" is displayed, desired Home channel frequency is changed and re-
turned to normal operation. 16 FT-4XR/FT-4XE Operating Manual Memory Channel Scanning The receiver may be set to scan memory channels:
1. While operating in the VFO mode, press the [ V/M] key to enter the Memory mode. 2. Press and hold the [] key or [] key. Scanning starts toward higher memory channel numbers. If the scanner halts on an incoming signal, the back light will turn ON and the decimal point between the MHz and kHz digits of the frequency display will blink. Scanning will resume in about five seconds. 3. Press the PTT switch to cancel the scanning. If the scan has paused on a signal, rotating the DIAL knob will cause scanning to resume next memory channel. Setting the Receive Operation When Scanning Stops Pressing and holding the Function key Pressing the key Pressing the Function key
(Entering the Set mode) 1. Press the [] key or [] key to select the operation performed after the
(Selecting "34 SCN.RSM") scan stops:
Display Description BUSY(Default setting) HOLD TIME In BUSY mode, the scanner will halt on a signal it encounters. Scanning will resume one second after the other station signal ceases transmitting. In the case of constant-carrier signals like Weather Station broadcasts, the scanner will likely remain on this frequency indefinitely. In HOLD mode, the scanner will halt on a signal it encounters. Scanning will only resume when it is manually re-initiated. In TIME mode, the scanner will halt on a signal it encounters, scanning will resume after five seconds even if a signal is still on the frequency. To cancel scanning, press the the PTT switch, [] or [] key. 17 FT-4XR/FT-4XE Operating Manual 2. Press the PTT switch to save the setting and exit to normal operation. The above setting (Set Mode [34 SCN.RSM])is common for all scanning operation. For additional details on the following functions, refer to the Advanced Manual which may be downloaded from the Yaesu website. Using Memory Tag Memory name tags may be assigned to the memory channels and home channels. Using Memory Bank The transceiver allows using up to 10 memory banks to allow sorting and registering thechannels in convenient groups. Scanning Function The transceiver supports the following four scanning functions:
VFO Scan Program Scan Memory Channel Scan Programmable Memory Scan(PMS) Memory Bank Scan For additional details on the Programmable Memory Scan (PMS) and Memory Bank Scan, refer to the Advanced Manual which may be downloaded from the Yaesu website. VFO Scan VFO scan function scans the frequencies, and detects signals. 1. Press the [ V/M] key to enter the VFO mode. 2. Press and hold the [] key or the [] to start scanning. 3. Press the PTT switch, [] or [] key to cancel scanning. z If the scan has paused on a signal, Turning the transceiver ON will cause scanning to resume instantly. z To set the transceiver action when scanning stops, see Setting the Receive Operation When Scanning Stops on page ] (
20). 18 FT-4XR/FT-4XE Operating Manual Using Set Mode The Set Mode permits configuring the various functions according to individual operating needs and preferences. 1. Press and hold the Function key. The previously selected Set Mode item is displayed. 2. Press the [] key or [] key to select the desired Set Mode item. 3. Press the function key, then press the [] key or
[] key to change the setting. Press the PTT switch to save the settings and return to normal operation. 4. z In step 4 above, press the Function key to save the new setting and return to Set Mode item to set the other Set Mode. z On some setting screens, key operation is different than described in the above steps (For example, inputting the characters, etc.). Refer to the Advance manual. For additional details, refer to the Advanced Manual which may be downloaded from the Yaesu website Tables of Set Mode Operations No. Set Mode item Description Selectable options
(Options in bold are the default settings) OFF / 0.5 Hours 12Hours 1 2 3 4 5 6 APO Sets the length of time until the transceiver turns off automatically. AR BEP Sets the beep option during ARTS operation. OFF / INRANG /
ALWAYS AR INT BCLO BEEP BELL Sets the polling interval during ARTS operation. Turns the busy channel lockout function ON/
OFF. Sets the beep function on pressing the keypad, or stopping the receiver scanning. 25 SEC / 15 SEC BCL.OFF / BCL.ON KEY+SC / KEY / OFF Selects the number of CTCSS/DCS/PAGER/
ARTS Bell ringer repetitions. OFF / 1 T / 3 T / 5 T / 8 T / CONT 19 FT-4XR/FT-4XE Operating Manual 13 DT SPD Sets the DTMF code transmission speed. 50MS / 100MS No. Set Mode item Description Selectable options
(Options in bold are the default settings) CWID Turns the CW Identifier ON/OFF during ARTS operation. TX OFF / TX ON 7 8 9 17 18 CW WRT Sets the CW ID during ARTS operation. DC VLT Displays the voltage. 10 DCS.COD Sets the DCS CODE RX and TX. 11 DT DLY 12 DT SET Sets the DTMF code transmission delay time. Selects the DTMF auto dialer memory channel and edits the DTMF code (Maximum 16 digits) 14 EDG.BEP Turns the the Band-edge beeper on/off. while selecting the frequency via the [] or
[] key. 15 LAMP Selects the LCD/Keypad Lamp mode. 16 LED.BSY LED.TX Turns the TX/BUSY lamp ON/OFF while receiving signals. Turns the TX/BUSY lamp ON/OFF while transmitting signals. LOCK Configures the lock mode setting. 19 M/T-CL Selects the function of the [MONI/T-CALL]
switch. 20 MEM.DEL Deletes the memory channel 21 MEM. TAG 22 PAG.ABK Edits the memory channel tag. Turns the pager answer back Function ON/
OFF 23 PAG.CDR Specifies a personal code (receive). 20 ID= (6 characters) default: blank
(Voltage) 104 DCS CODEs / OFF default: 023 R / 023 T 50MS / 250MS / 450MS
/ 750MS / 1000MS d1 d9 BEP.OFF / BEP. ON 5 SEC / 10 SEC / 30 SEC / CONT / OFF BSY ON / BSYOFF TX ON / TXOFF LK KEY / LK PTT / LK P+K MONI / TC1750* /
TC2100 / TC1000 /
TC1450
(*: Eurpean / Asian Version) ABK.OFF / ABK. ON 01 05 50, 01 47 50 FT-4XR/FT-4XE Operating Manual No. Set Mode item Description 24 PAG.CDT Specifies a personal code (transmit). 25 PRI.RVT Turns the Priority Revert feature ON/OFF. 26 PSWD Turns the Password feature ON/OFF. 27 PSWDWT Inputs the password. 28 RF SQL Adjusts the RF Squelch threshold level. 29 RPT.ARS Turns the ARS function on/off. 30 RPT.FRQ Sets the repeater shift width. 31 RPT.SFT Sets the repeater shift direction. 32 RXSAVE Selects the Receivemode Battery Saver interval (sleep ratio) Selectable options
(Options in bold are the default settings) 01 05 50, 01 47 50 RVTOFF / RVT ON PWD.OFF / PWD. ON
(4 digits) OFF / S-1 / S-2 / S-3
/ S-4 /S-5 / S-6 / S-8 /
S-FULL ARS.ON / ARS.OFF OFF / 0.05MHz 99.95MHz SIMPLX / +RPT / -RPT 200 MS 2 SEC / OFF 33 SCN.LMP Turns the scan lamp ON/OFF while paused. 34 SCN.RSM Configures the scan stop mode settings. ON / OFF BUSY / HOLD / TIME 35 SKIP Turns the Memory Scan Skip channel selection mode ON/OFF. OFF / SKIP 36 SQL.TYP Selects the Tone Encoder and/or Decoder mode. 37 STEP Sets the frequency steps. 38 TN FRQ Sets the TONE frequency. 39 TOT Sets the timeout timer. 40 TX PWR Selects Transmitter Power OFF / R-TONE /
T-TONE / TSQL / REV TN / DCS / PAGER AUTO /5.0 / 6.25 / 10.0 /
12.5 / 15.0 / 20.0 / 25.0 /
50.0 / 100.0 k OFF / 67.0 R 100.0 R 254.1 R OFF / 67.0 T 100.0 T 254.1 T OFF / 1MIN 3MIN 30MIN HIGH (5W) / MID (2.5W)
/ LOW (0.5W) 41 TX SAVE Turns the Transmitter Battery Saver ON/OFF. SAVOFF / SAV ON VSP.OFF / VSP. ON 42 VFO.SPL Turns the VFO Split operation ON/OFF. 21 FT-4XR/FT-4XE Operating Manual No. Set Mode item Description Selectable options
(Options in bold are the default settings) 43 VOX 44 W/N.DEV 45 WX ALT Turns the VOX function ON/OFF. Sets the Transmit Modulation Level in the FM mode. Turns the Weather Alert Scan ON/OFF. VOXOFF/ VOX ON WIDE / NARROW ALT.OFF / ALT. ON 22 FT-4XR/FT-4XE Operating Manual Restoring to Defaults (Reset) / Setting the Preferred Operating Mode The following reset or preferred operating modes may be selected. 1. Turn the transceiver OFF. 2. Press and hold the MONI/T.CALL key and the PTT switch simultaneously, while turning the transciever ON. 3. When the LCD backlight comes on, release the MONI/T.CALL key and PTT switch. 4. Referring to the above table, press the [] or
[] key to select the desired resets or desired operating modes. Display Description F1:SET RST Resets the Set Mode settings to factory defaults. F2:MEM RST Clears the Memory settings to factory defaults. F3:MB. RST Clears the Memory Bank assignments. F4:ALL RST Clears the All memories and other settings to F5:M-ONLY Operation on the Memory mode only. F6:CLONE Clone mode. factory defaults. CAUTION!
Resetting the transceiver (F2 MEM RST / F4 ALL RST) will clear all memories. Please make a note of the memories (memory channel settings, etc) before resetting. z To cancel this operation, turn the transceiver OFF. z Perform All Reset to restore all of the following Set Mode items to default. 10 DCS.COD 26 PSWD 35 SKIP 44 W/N.DEV 36 SQL.TYP 37 STEP 27 PSWDWT 30 RPT.FRQ 31 RPT.SFT 38 TN FRQ 40 TX PWR 23 FT-4XR/FT-4XE Operating Manual Specifications General Frequency Range RX: 136 - 174MHz, 400-480MHz TX: 136 - 174 MHz (Asian version) 144 - 146 MHz (European version) 144 - 148 MHz (USA version) 400 - 480 MHz (Asian version) 430 - 440 MHz (European version) 430 - 450 MHz (USA version) FM Broadcast: 65 - 108 MHz Channel Steps Mode of Emission Frequency Stability Antenna Impedance Supply Voltage Nominal: 7.4 V DC, Negative Ground SBR-28LI Current Consumption
(Approx.)
: 5/10/12.5/15/20/25/50/100kHz
: F2DF3EF2A
: 2.5ppm (20 C to +60 C [4 F to +140 F])
: 50 ohms
:
190 mA (Receive) 200 mW Output 95 mA (Standby, Saver Off) 23 mA (Standby, Saver On) 5 mA (Auto Power Off) 1.5 A (5 W Tx , 144 MHz) 7.4 V DC 1.7 A (5 W Tx , 430 MHz) 7.4 V DC Operating Temperature Case Size Weight (Approx.) Transmitter RF Power Output Modulation Type Maximum Deviation Spurious Emission
: 4 F to +140 F ( 20 C to + 60 C)
: 2.0 (W) x 3.5 (H) x 1.2 (D) (529030mm)
(W/O knob and antenna)
: 9.17 oz (250g) with SBR-28LI and antenna
: 5.0 W (High) / 2.5 W (Middle) / 0.5 W (Low)
(@ 7.4 V with SBR-28LI)
: Variable Reactance
: 5.0 kHz
: USA/Asian version At least 60 dB below (@TX Power High, Middle) At least 50 dB below (@TX Power Low) European version At least 60 dB below (@TX Power High, Middle) At least 55 dB below (@TX Power Low) 2 k Microphone Impedance :
(Approx.) 24 FT-4XR/FT-4XE Operating Manual Receiver Circuit Type Sensitivity
: Double-conversion
: 0.2 V for 12 dB SINAD (140 - 150 MHz, NFM) 0.2 V for 12 dB SINAD (420 - 470 MHz, NFM) Selectivity (-65 dB/-60 dB) : FM, NFM 25 kHz / 12.5 kHz AF Output
: 800 mW (16 for THD 10 % 7.4 V DC) internal speaker 800 mW (16 for THD 10 % 7.4 V DC) external speaker Specifications are subject to change without notice, and are guaranteed within the 144 and 430 MHz amateur bands only. Frequency ranges will vary according to transceiver version;
check with your dealer. 25 FT-4XR/FT-4XE Operating Manual 1. Changes or modifications to this device that are not expressly approved by YAESU MUSEN could void the users authorization to operate this device. 2. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference including received, interference that may cause undesired operation. 3. The scanning receiver in this equipment is incapable of tuning, or readily being altered, by the User to operate within the frequency bands allocated to the Domestic public Cellular Telecommunications Service in Part 22. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes : (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. DECLARATION BY MANUFACTURER The Scanner receiver is not a digital scanner and is incapable of being converted or modified to a digital scanner receiver by any user. WARNING: MODIFICATION OF THIS DEVICE TO RECEIVE CELLULAR RADIOTELEPHONE SERVICE SIGNALS IS PROHIBITED UNDER FCC RULES AND FEDERAL LAW. 26 FT-4XR/FT-4XE Operating Manual Copyright 2018 YAESU MUSEN CO., LTD. All rights reserved. No portion of this manual may be reproduced without the permission of YAESU MUSEN CO., LTD. YAESU MUSEN CO., LTD. Tennozu Parkside Building 2-5-8 Higashi-Shinagawa, Shinagawa-ku, Tokyo 140-0002 Japan YAESU USA 6125 Phyllis Drive, Cypress, CA 90630, U.S.A. YAESU UK Unit 12, Sun Valley Business Park, Winnall Close Winchester, Hampshire, SO23 0LB, U.K. Printed in Japan
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2018-02-23 | 400 ~ 480 | CSR - Scanning Receiver | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2018-02-23
|
||||
1 | Applicant's complete, legal business name |
Yaesu Musen Co., Ltd.
|
||||
1 | FCC Registration Number (FRN) |
0013655220
|
||||
1 | Physical Address |
Tennozu Parkside Building
|
||||
1 |
Tokyo, N/A 140-0002
|
|||||
1 |
Japan
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
T******@TIMCOENGR.COM
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
K66
|
||||
1 | Equipment Product Code |
20695X20
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
K****** T****
|
||||
1 | Title |
Engineering Division/Quality Assurance Leader
|
||||
1 | Telephone Number |
81-3-********
|
||||
1 | Fax Number |
81-3-********
|
||||
1 |
k******@yaesu.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 08/22/2018 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | CSR - Scanning Receiver | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | FM DUAL BAND TRANSCEIVER | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Timco Engineering, Inc.
|
||||
1 | Name |
B**** C******
|
||||
1 | Telephone Number |
352-4********
|
||||
1 | Fax Number |
352 4********
|
||||
1 |
b******@timcoengr.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15B | 136 | 174 | |||||||||||||||||||||||||||||||||||||
1 | 2 | 15B | 400 | 480 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC