SiXCOMBO Combination Smoke/Carbon Monoxide (CO) Detector / Combinacin de detector de Humo/Monxido de carbono (CO) Quick Installation Guide Gua Rpida de Instalacin This device is intended for use with Honeywell controls that support SiX series devices including the SiXCOMBO. Check the control for compatibility with this device. This device occupies 3 control panel zones, one zone for each service
(smoke detection, heat detection, carbon monoxide detection). FEATURES Multi-Criteria Sensing: uses four sensing elements to react faster while Este producto est diseado para ser usado en controladores Honeywell que soportan dispositivos de la serie SiX including the SiXCOMBO. Check the control for compatibility with this device. This device occupies 3 control panel zones, one zone for each service (smoke detection, heat detection, carbon monoxide detection). CARACTERISTICAS minimizing false alarms:
- Photoelectric smoke sensor detects airborne smoke particles
- Carbon Monoxide (CO) sensor detects smoldering fires
- Infrared (IR) sensor measures ambient light and flame signatures, such as flame flicker
- Thermal detection monitors for dangerous rise in temperature CO Detector End-of-Life reporting (detector needs replacing) Smoke detector maintenance reporting (detector needs cleaning or replacing) Low Battery Detection One Go / All Go: all smoke/CO detectors in the system programmed as one-go-
all-go will sound on alarm. Voice announcements (English only) See Installation Instructions (800-22142 https://mywebtech.honeywell.com/) and the Limitations of Fire Alarm Systems Insert (800-15144 12/15) and System Smoke Detectors Application Guide (SPAG9101 7/12). LED INDICATORS The SiXCOMBO Smoke/CO detector has a multi-color top LED:
Green = Supervisory indication; blinks during power on, reset, and during normal operation Amber = Signal maintenance and trouble events Red = Alarm condition (either Smoke or CO) Side LED windows indicate alarms:
Red = smoke alarm Blue = CO alarm ENROLLMENT IMPORTANT NOTES:
The Smoke, Heat, and Carbon Monoxide (CO) sensors each have unique MAC ID numbers (serial numbers) that are enrolled in separate zones. Once enrolled, the device cannot be used with another system until it is removed from the current controller. See the 24-hour Enrollment Deletion section below or the controllers instructions. Enroll the Device Services (Smoke, Heat, CO) 1. Remove the detector from the base plate (tamper switch must be faulted when enrolling). 2. Put the control panel in Zone Programming mode. For Lyric Controller: Security > installer code > Program
> (scroll down) > SiX Programming 3. Pull the battery tab to activate enrollment process (be sure batteries are seated properly to avoid a false low battery condition). If the battery tab has already been removed and the unit is powered up, press either Test switch for less than 3 seconds to activate the enrollment process. 4. The device attempts enrollment (green LED flashes about 8 seconds). If successful, the green LED lights steady for 3 seconds and the device announces successful enrollment. If the LED does not light steady, enrollment failed. Retry by pressing either Test switch for less than 3 seconds. All services (Smoke, Heat, and CO) are automatically enrolled in sequential (or next available) zone numbers with the following default attributes:
Zone Smoke Det. Smoke Detector Heat Det. CO Det. Zone Response Type Fire No Verification Heat Sensor Fire No Verification Carbon Mono. Det. Carbon Monoxide Device Type NOTE: Maintenance and CO End-of-Life are automatically enrolled for the respective smoke and CO zones. Upon either of these conditions, Contact ID code E386 Low Maintenance Smoke is sent for the respective zone. Supervision: Detector supervision is factory set for 1 minute and is not programmable. 5. To assign zone descriptors for each of the zones and/or change device type or zone response type, select the zone then select Edit and make the desired changes. Press Save when done. 24-Hour Enrollment Deletion Use this procedure within 24 hours of initial enrollment to delete this device from the controller. This allows reenrollment in a specific controller in case enrollment in that controller failed
(i.e., the device inadvertently enrolled in a different controller). This resets the device to factory default settings and removes the communication link data in the controller in which it is enrolled, allowing the device to be reenrolled in the desired controller. 1. Press and hold both the Smoke and CO test switches simultaneously for 5 seconds, then release. The green light flashes rapidly. 2. Press and hold both buttons again for one second and release. MOUNTING If the device is not in its final mounting location when enrolled, conduct Go/No Go tests (see controllers instructions) to verify adequate signal strength. Adjust the device location and orientation as necessary. Deteccin multi-criterio: Utiliza cuatro elementos de deteccin para una ms rpida reaccin mientras se minimizan falsas alarmas:
- Sensores fotoelctricos de humo que detectan partculas de humo en el aire
- Sensores de deteccin de Monxido de Carbono (CO) para deteccin de incendios sin llama
- Sensores infrarrojos (IR) que detectan luces de ambiente y seales de flamas tales como movimiento de las llamas
- Deteccin termal que monitorea aumento peligroso de temperaturas Fin de vida til del detector de CO (el detector necesita ser remplazado) Reporte de mantenimiento del sensor de humo (Cuando el sensor requiere limpieza or replacing) Deteccin de batera baja. Uno se activa / Todos se activan: todos los detectores de humo/CO en el sistema programados como uno se activa/todos se activan, sonarn su propia alarma Voice announcements (English only) Vea la gua de instalacin de Honeywell (800-22142-
https://mywebtech.honeywell.com/) y el inserto de las limitaciones de sistemas de alarma de fuego. (800-15144SP 12/15). Consulte la Gua de aplicacin de detectores de humo del sistema (SPAG9101 7/12). INDICADORES DE LED El detector de humo/Monxido de carbono SiXCOMBO contiene un LED multicolor:
Verde = Indicador de supervisin; parpadea durante iniciacin, reinicio y durante operacin normal. mbar = Seal de eventos de mantenimiento o problemas Rojo = Condicin de alarma (de humo o monxido de carbono) Ventanas de LED laterales: Rojo = Humo, Azul = Monxido de carbon REGISTRO NOTA IMPORTANTE:
The Smoke, Heat, and Carbon Monoxide (CO) sensors each have unique MAC ID numbers (serial numbers) that are enrolled in separate zones. Una vez registrado, el dispositivo no se puede usar con otro sistema hasta que sea removido del controlador actual. See the 24-hour Enrollment Deletion section below or the controllers instructions. Enroll the Device Services (Smoke, Heat, CO) 1. Remove the detector from the base plate (tamper switch must be faulted when enrolling). Voice welcome, instructions after first time power-up or after default
/ Bienvenida de voz, seguido por las instrucciones POR para la seleccin de lenguaje, enrolamiento, pruebas Silent /
Silencio Warning, smoke, evacuate/
Advertencia, humo, evacuar Warning, smoke, evacuate/
Advertencia, humo, evacuar Warning, carbn monoxide, move to fresh air /
Advertencia, monxido de carbn, pasar al aire fresco 2. Put the control panel in Zone Programming mode. For Lyric Controller: Security > installer code > Program >
(scroll down) > SiX Programming 3. Pull the battery tab to activate enrollment process (be sure batteries are seated properly to avoid a false low battery condition). If the battery tab has already been removed and the unit is powered up, press either Test switch for less than 3 seconds to activate the enrollment process. 4. The device attempts enrollment (green LED flashes about 8 seconds). If successful, the green LED lights steady for 3 seconds and the device announces successful enrollment. If the LED does not light steady, enrollment failed. Retry by pressing either Test switch for less than 3 seconds. All services (Smoke, Heat, and CO) are automatically enrolled in sequential (or next available) zone numbers with the following default attributes:
Zone Smoke Det. Smoke Detector Heat Det. CO Det. Zone Response Type Fire No Verification Heat Sensor Fire No Verification Carbon Mono. Det. Carbon Monoxide Device Type NOTE: Maintenance and CO End-of-Life are automatically enrolled for the respective smoke and CO zones. Upon either of these conditions, Contact ID code E386 Low Maintenance Smoke is sent for the respective zone. Supervision: Detector supervision is factory set for 1 minute and is not programmable. 5. To assign zone descriptors for each of the zones and/or change device type or zone response type, select the zone then select Edit and make the desired changes. Press Save when done. 24-Hour Enrollment Deletion Use this procedure within 24 hours of initial enrollment to delete this device from the controller. This allows reenrollment in a specific controller in case enrollment in that controller failed (i.e., the device inadvertently enrolled in a different controller). This resets the device to factory default settings and removes the communication link data in the controller in which it is enrolled, allowing the device to be reenrolled in the desired controller. 1. Press and hold both the Smoke and CO test switches simultaneously for 5 seconds, then release. The green light flashes rapidly. 2. Press and hold both buttons again for one second and release. OPEN / ABIERTO Operation Modes / Modos de operacin MODE / MODO Status LED (Top) /
Estado del LED LED Windows
(Side) / Ventana del LED (Lateral) Sounder /
Sonador Speaker / Bocina Power Up /
Encendido Blink Green, every 2 secs/ Parpadea verde cada 2 segundos Dark /
Apagado Silent /
Silencio Normal (Standby)
/
Estado normal Smoke Alarm /
Alarma de humo Thermal Alarm /
Alarma termal Single Blink Green every 10 sec /
parpadeo verde cada 10 segundos Blink Red every 10 secs / parpadeo rojo cada 10 segundos Blink Red every 10 secs / parpadeo rojo cada 10 segundos Dark /
Apagado Blink Red /
Parpadeo rojo Blink Red /
Parpadeo rojo CO Alarm / Alarma de monxido de carbono Blink Red every 10 secs / parpadeo rojo cada 10 segundos Blink Blue /
Parpadeo azul Silent /
Silencio Temp-3 Temp-3 Temp-4 Silent /
Silencio Silent /
Silencio Dark /
Apagado Powered Down /
Dark /
Apagado Apagado TO SILENCE THE DETECTOR Press the test switch. The detector sounds again after 5 minutes if the alarm condition continues. PARA SILENCIAR EL DETECTOR Presione el interruptor de prueba. El detector volver a sonar despus de 5 minutos si contina la condicin que origin la alarma. MONTAJE Si el dispositivo no est en su ubicacin final de montaje cuando se registre, realice pruebas de Va/No Va (vea las instrucciones del controlador) para verificar que la intensidad de la seal sea adecuada. Ajuste la ubicacin y orientacin del dispositivo segn ea necesario. FUNCTIONAL TESTING CANNED SMOKE NOTE: Detector sounds an alarm when using canned smoke only when in Functional Test mode (canned smoke does not cause alarm sounding when in normal mode). Product must be tested at least once each year PRUEBAS FUNCIONALES NOTA: El detector emite una alarma cuando se utiliza el humo en conserva slo cuando est en modo de prueba (el humo en lata no provoca sonidos de alarma cuando est en modo normal). El producto debe ser probado al menos una vez al ao
* Use UL/ANSI Approved canned smoke.
* Uso UL / ANSI Aprobado humo en lata. LED Indication & Sounder during Test and Trouble /
Indicacin de LED y sonidos durante prueba y falla eight Sounder / Sonador Side LED Windows/
Ventana del LED MODE/ MODO Status LED (Top) /
Estado del LED
(Lateral) Speaker / Bocina Voice smoke sensor test result and remaining battery life /
Resultado de prueba de humo de voz y duracin de la batera restante Voice instructions and warning of alarm signal /
Instrucciones y advertencia de alarma va voz Smoke Test 1ab / Prueba de alarma de humo Blink Red once every sec /
parpadeo rojo una vez cada Segundo Blink Green once a sec/
parpadeo vert una vez cada Segundo Functional SMOKE Test1ab Waiting for canned smoke entry / Prueba funcional de alarma de humo esperando por prueba de humo Functional SMOKE Test -
Successful smoke entry /
Prueba funcional de alarma de humo prueba de humo exitosa Dark /
Apagado Dark /
Apagado Temp-3 Silent /
Silencio Blink Red every 10 secs /
parpadeo rojo cada 10 segundos Blink Red every 10 secs /
Parpadeo rojo cada 10 segundos Temp-3 CO Test 1ab / Prueba de alarma de monxido de carbono Blink Red once every sec /
parpadeo rojo una vez cada Segundo Dark /
Apagado Voice CO sensor test result, remaining sensor life, and remaining battery life /
Resultado de la prueba del sensor de CO de la voz, vida til restante del sensor y duracin de la batera restante Voice instructions and warning of alarm signal /
Instrucciones y advertencia de alarma va voz Warning, carbn monoxide, move to fresh air /
Advertencia, monxido de carbn, pasar al aire fresco Temp-4 Silent /
Silencio Temp-4 Voice instructions when chirp is hushed by pressing either test button /
Instrucciones cuando el chirrido es apagado usando cualquier botn de prueba va voz Voice smoke maintenance instructions if either test button is pressed /
Instrucciones para el mantenimiento del sensor de humo Voice CO sensor failure
(if CO Test button pressed) Error del sensor de voz CO
(Si se pulsa el botn CO Test) Voice end of life instructions when either test button is pressed /Instrucciones de fina de vida va voz Voice end of life instructions when either test button is pressed /Instrucciones de fina Silent /
Silencio Silent /
Silencio Silent /
Silencio Chirp every 45 seconds after 7 days / Un chirrido cada 45 segundos despus de 7 das Blink Green once a sec /
parpadeo vert una vez cada Segundo Dark /
Apagado Blink Red every 10 secs /
parpadeo rojo cada 10 segundos Blink Blue every 10 secs /
Parpadeo azul cada 10 segundos RealTest Functional CO Test1ab Waiting for gas entry / RealTest Prueba funcional de monxido de carbono esperando por prueba de gas RealTest Functional CO Test - Successful gas entry
/
RealTest Prueba funcional de monxido de carbono prueba de gas exitosa Low Battery /
Batera baja Smoke Maintenance3 /
Mantenimiento del sensor de humo3 Blink Amber every 10 sec /
parpadeo mbar una vez cada Segundo Blink Amber every 5 secs /
parpadeo color mbar cada 5 segundos CO Trouble/
Problema con el sensor de monxido de carbono Double Blink Amber every 5 secs / parpadeo color mbar cada 5 segundos CO End of Life2- First 29 days Final de vida del sensor de monxido de carbono CO End of Life2- After 30 days
/
/
Double Blink Amber every 3 secs / Doble parpadeo color mbar cada 3 segundos Double Blink Amber every 3 secs / Doble parpadeo color mbar cada 3 segundos Blink Red every 10 secs /
parpadeo rojo cada 10 Dark /
Apagado Dark /
Apagado Dark /
Apagado Dark /
Apagado Dark /
Apagado Chirp every 45 secs/ Un chirrido cada 45 segundos Final de vida del sensor de monxido de carbono Freeze Warning (low temp) /
Alarma contra congelacin
(baja temperatura) 1a Test activated by pressing and releasing the test switch; Detector is functioning properly (within proper sensitivity). See Functional Test de vida va voz section for Functional Test activation and procedure. / Prueba activada por el interruptor de prueba; El detector est funcionando correctamente (Dentro de la sensibilidad adecuada). Consulte la seccin Prueba funcional para la activacin y el procedimiento de la prueba funcional. 1b If Test mode is activated and the LED and Sounder do not function, check for maintenance or trouble conditions./ Si se activa el modo segundos de prueba y ni el led ni la sirena funcionan, verifique el mantenimiento o las condiciones problema. 2 Starts chirping after 30 days, continues until the batteries are replaced or die / Comienza el chirrido despus de 30 das y contina hasta que las bateras son cambiadas o se agotan. 3. See Periodic Cleaning section. If maintenance trouble condition persists, the detector may need to be replaced. NOTE: For programming Smoke or CO alarms and Tamper, see the Controllers instructions. NOTA: Para programar las alarmas de Humo o Calor y Manipulacin, ver las instrucciones del Controlador. Support / Soutien https://mywebtech.honeywell.com/
U.S. warranty / U.S. garantie: www.honeywell.com/security/hsc/resources/wa For patent information, see: / Para informacin de Patentes, vea : www.honeywell.com/patents MyWebTech Warranty Garantie Patents Patentes PERIODIC CLEANING NOTE: Notify the proper authorities that the smoke detector is undergoing maintenance and the system will temporarily be out of service. LIMPIEZA PERIDICA NOTA: Reporte a las autoridades competentes que el detector de humo se encuentra en mantenimiento y que el sistema est temporalmente fuera de servicio. BATTERY REPLACEMENT / CAMBIO BATERA Caution: The batteries used in this device may present a fire or chemical burn hazard if mistreated. Do not recharge, disassemble, heat above 100C (212F) or dispose of in fire. Use only Panasonic CR123A Lithium batteries. Use of other batteries may present a risk of fire or explosion. Keep used batteries away from children. Dispose of used batteries properly. Remove old batteries. Wait 10 seconds and then replace with four new batteries. To avoid a low battery indication when installing new batteries, all 4 batteries must be installed within 15 seconds of installing the first one. Any low battery condition that may have occurred should clear when the backplate is installed. Precaucin: las bateras utilizadas en este dispositivo pueden generar un peligro de incendio o quemadura qumica si no son tratadas adecuadamente. No recargue, desarme, caliente a ms de 100C (212F) o arroje al fuego. Use solamente bateras de litio Panasonic CR123A. Cuando instale las nuevas bateras, El uso de otras bateras puede presentar un riesgo de incendio o explosin. Mantenga las bateras usadas lejos del alcance de los nios. Descarte apropiadamente las bateras usadas. Remueva las bateras usadas, espere 10 segundos y coloque 4 bateras nuevas. Para evitar la indicacin de batera baja cuando se instalen bateras nuevas, las 4 baterias debern de ser instaladas en menos de 15 segundos despus de la instalacin de la primera batera. Cualquier cindicacion de batera baja que haya ocurrido, desaparecer cuando la placa trasera sea colocada. Approval Listings / Listas de aprobaciones:
FCC Listed to UL268 & UL 2075 / Con certificaciones UL 268 y UL 2075. Other Standards / Otras normas: RoHS NOTE: Smoke detectors are not to be used with detector guards unless the combination is evaluated and found suitable for that purpose. NOTA: Los detectores de humo no se deben usar con protecciones de detector a menos que la combinacin se haya evaluado y comprobado que es adecuada para ese propsito. Specifications / Especificaciones:
Battery / Batera: 4 x 3V, CR123A Lithium; Panasonic CR123A only / CR123A litio Sensitivity / Sensibilidad: UL limits 0.9 to 3.50%/ft ; ULC limits 0.9 to 3.08 %/ft /
Lmites UL 0,9 a 3,50 %/pie / lmites ULC 0,9 a 3,08 %/pie Thermal alarm: 135 F (57 C) / Alarma trmica: 135 F (57 C) Freeze trouble: 41 F typical (5 C) / Problema de congelacin: 41 F tpico (5 C) Audible Signal: 85dBA / Seal audible: 85 dBA Dimensions / Dimensiones:16.002 cm Diameter x 4.19 cm Thick / 6.3 in. Diameter x 1.65 in. Thick /
Dimetro: 16,002 cm x 4,19 cm espesor / 6,3 pulg. dimetro x 1,65 pulg. espesor Weight: 14.3 oz; 406 g / Peso: 14,3 oz; 406 g Tamper / Tamper: Cover Operating Temperature /Temperatura de funcionamiento: 32 100 F / 0 38 C Storage Temperature / Rango de temperatura de almacenamiento: -10-70C (14-158F) Relative Humidity / Humedad relativa:
20-95% RH (Agency Compliance 93% max.), non-condensing NOTE: Batteries available at your local retailer or distribution center. NOTA : Las bateras estn disponibles en los distribuidores locales. FEDERAL COMMUNICATIONS COMMISSION The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. DECLARACIONES DE LA COMISIN FEDERAL DE COMUNICACIONES (FCC) El usuario no efectuar ningn cambio ni modificacin al equipo, a menos que estuviera autorizado en las Instrucciones de instalacin o en el Manual de usuario. Las modificaciones o cambios no autorizados pueden anular la autoridad del usuario para operar el equipo. FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. DECLARACIN DE FCC Este dispositivo cumple con la Parte 15 de las Reglas de la FCC. El funcionamiento est sujeto a las siguientes dos condiciones: (1) Este dispositivo no provoca ninguna interferencia perjudicial, y (2) Este dispositivo aceptar cualquier interferencia que reciba, incluida una interferencia que pueda provocar un funcionamiento no deseado. DECLARACIN IFETEL La operacin de este equipo est sujeta a las siguientes dos condiciones 1. Es posible que este equipo o dispositivo no cause interferencia perjudicial y 2. Este equipo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operacin no deseada. REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM. CONSULTE LAS INSTRUCCIONES DE INSTALACIN PARA EL CONTROL CON EL CUAL SE UTILIZA ESTE DISPOSITIVO, PARA OBTENER DETALLES CON RESPECTO A LAS LIMITACIONES DE TODO EL SISTEMA DE ALARMA. Agile ref. #800-xxxxx 7/17 Rev A I56-6260-000 2017 Honeywell International Inc. Honeywell and is a registered trademark of Honeywell International Inc. All other trademarks are the properties of their respective owners. All rights reserved www.honeywell.com/security 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747