all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 2.19 MiB | August 07 2020 | |||
1 |
|
Internal Photos | Internal Photos | 776.67 KiB | August 07 2020 | |||
1 |
|
External Photos | External Photos | 176.50 KiB | August 07 2020 | |||
1 |
|
Label | ID Label/Location Info | 88.24 KiB | August 07 2020 | |||
1 |
|
Applicant Declaration Letter | Cover Letter(s) | 128.94 KiB | August 07 2020 | |||
1 | Block Diagram | Block Diagram | August 07 2020 | confidential | ||||
1 |
|
MPE Report | RF Exposure Info | 326.06 KiB | August 07 2020 | |||
1 | Operation Description | Operational Description | August 07 2020 | confidential | ||||
1 |
|
Power of Attorney Letter | Cover Letter(s) | 39.42 KiB | August 07 2020 | |||
1 | Schematic | Schematics | August 07 2020 | confidential | ||||
1 |
|
Test Report | Test Report | 952.39 KiB | August 07 2020 | |||
1 |
|
Test Setup Photo | Test Setup Photos | 256.38 KiB | August 07 2020 | |||
1 |
|
confidentiality request | Cover Letter(s) | 87.74 KiB | August 07 2020 |
1 | User Manual | Users Manual | 2.19 MiB | August 07 2020 |
Door Station User Manual Video Intercom D Series Door Station User Manual Legal Information 2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved. About this Manual The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website ( https://www.hikvision.com/ ). Please use this Manual with the guidance and assistance of professionals trained in supporting the Product. and other Hikvision's trademarks and logos are the properties of Hikvision in various jurisdictions. Other trademarks and logos mentioned are the properties of their respective owners. Trademarks Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED AS IS AND WITH ALL FAULTS AND ERRORS. HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN i Video Intercom D Series Door Station User Manual CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS. ii Video Intercom D Series Door Station User Manual Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Danger Caution Note Indicates a hazardous situation which, if not avoided, will or could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance degradation, or unexpected results. Provides additional information to emphasize or supplement important points of the main text. iii Video Intercom D Series Door Station User Manual Safety Instruction Warning All the electronic operation should be strictly compliance with the electrical safety regulations, fire prevention regulations and other related regulations in your local region. Please use the power adapter, which is provided by normal company. The power consumption cannot be less than the required value. Do not connect several devices to one power adapter as adapter overload may cause over-heat or fire hazard. Please make sure that the power has been disconnected before you wire, install or dismantle the device. When the product is installed on wall or ceiling, the device shall be firmly fixed. If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then please contact the service center. If the product does not work properly, please contact your dealer or the nearest service center. Never attempt to disassemble the device yourself. (We shall not assume any responsibility for problems caused by unauthorized repair or maintenance.) Caution Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment damage). Do not place the device in extremely hot (refer to the specification of the device for the detailed operating temperature), cold, dusty or damp locations, and do not expose it to high electromagnetic radiation. The device cover for indoor use shall be kept from rain and moisture. Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is forbidden (ignorance can cause fire danger). Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfunction however), and affecting the endurance of sensor at the same time. iv Video Intercom D Series Door Station User Manual Please use the provided glove when open up the device cover, avoid direct contact with the device cover, because the acidic sweat of the fingers may erode the surface coating of the device cover. Please use a soft and dry cloth when clean inside and outside surfaces of the device cover, do not use alkaline detergents. Please keep all wrappers after unpack them for future use. In case of any failure occurred, you need to return the device to the factory with the original wrapper. Transportation without the original wrapper may result in damage on the device and lead to additional costs. Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or equivalent type only. Dispose of used batteries according to the instructions provided by the battery manufacturer. Improper replacement of the battery with an incorrect type may defeat a safeguard (for example, in case of some lithium battery types). Do not dispose of the battery into fire or a hot oven, or mechanically crush or cut the battery, which may result in an explosion. Do not leave the battery in an extremely high temperature surrounding environment, which may result in an explosion or leakage of flammable liquid or gas. Do not subject the battery to extremely low air pressure, which may result in an explosion or the leakage of flammable liquid or gas. CAUTION: Risk of explosion if the battery is replaced by an incorrect type. v Video Intercom D Series Door Station User Manual Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help FCC Conditions This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC/IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. vi Video Intercom D Series Door Station User Manual ce matriel est conforme aux limites de dose d'exposition aux rayonnements, FCC / CNR-102 nonce dans un autre environnement. EU Conformity Statement This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014/30/EU, the RoHS Directive 2011/65/EU 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info 2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see:www.recyclethis.info Industry Canada ICES-003 Compliance This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
this device may not cause interference, and 1. 2. this device must accept any interference, including interference that may cause undesired operation of the device. vii Video Intercom D Series Door Station User Manual Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploitation est autorise aux deux conditions suivantes :
1. 2. l'appareil ne doit pas produire de brouillage, et l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformment la rglementation d'Industrie Canada, le prsent metteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou infrieur) approuv pour l'metteur par Industrie Canada. Dans le but de rduire les risques de brouillage radiolectrique l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonne quivalente (p.i.r.e.) ne dpasse pas l'intensit ncessaire l'tablissement d'une communication satisfaisante. viii Video Intercom D Series Door Station User Manual Contents 1 Appearance Description ............................................................................. 1 1.1 Appearance of 80 Series Door Station .............................................................. 1 1.2 Appearance of 81 Series Door Station .............................................................. 2 1.3 Appearance of 30 Series Door Station .............................................................. 2 2 Terminal and Wiring Description ................................................................ 4 2.1 Terminal Description ......................................................................................... 4 2.2 Wiring Description ............................................................................................ 6 2.2.1 D-Series Door Lock Wiring ........................................................................ 6 2.2.2 D-Series Door Contact Wiring (8081 Series) ............................................. 6 2.2.3 D-Series Exit Button Wiring (8081 Series) ................................................ 7 2.2.4 External Card Reader Wiring .................................................................... 8 2.2.5 D-Series Elevator Controller Wiring ........................................................ 10 2.2.6 Alarm Input Device Wiring ..................................................................... 10 2.2.7 Alarm Output Device Wiring .................................................................. 11 3 Installation ................................................................................................ 13 3.1 Installation of 80 Series Door Station .............................................................. 13 3.1.1 Gang Box for 80 Series Door Station ...................................................... 13 3.1.2 Flush Mounting with Gang Box .............................................................. 13 3.2 Installation of 81 Series Door Station .............................................................. 16 3.2.1 Gang Box for 81 Series Door Station ...................................................... 16 3.2.2 Flush Mounting with Gang Box .............................................................. 17 3.3 Installation of 30 Series Door Station .............................................................. 18 ix Video Intercom D Series Door Station User Manual 3.3.1 Gang Box of 30 Series Door Station ........................................................ 19 3.3.2 Flush Mounting with Gang Box .............................................................. 19 4 Activation ................................................................................................. 22 4.1 Activate Device Locally .................................................................................... 22 4.2 Activate Device via Client Software ................................................................. 23 4.3 Activate Device via Web .................................................................................. 24 5 Local Operation ........................................................................................ 25 5.1 Local Configuration ......................................................................................... 25 5.1.1 Edit Network Parameters ........................................................................ 25 5.1.2 Door Station Settings .............................................................................. 25 5.1.3 Add Residents ......................................................................................... 26 5.1.4 About ...................................................................................................... 27 5.2 Video Intercom Operation .............................................................................. 27 5.2.1 Call Resident ........................................................................................... 27 5.2.2 Call Center .............................................................................................. 28 5.3 Unlock Door .................................................................................................... 28 5.3.1 Unlock by Password ................................................................................ 28 5.3.2 Unlock by Presenting Card ...................................................................... 29 5.3.3 Unlock by Fingerprint ............................................................................. 29 5.3.4 Unlock by QR Code ................................................................................. 29 6 Remote Configuration via Web ................................................................ 31 6.1 Live View ......................................................................................................... 31 6.2 User Management .......................................................................................... 31 6.3 Device Management ....................................................................................... 32 x Video Intercom D Series Door Station User Manual 6.4 Parameters Settings ........................................................................................ 32 6.4.1 Local Parameters Settings ....................................................................... 32 6.4.2 System Settings ....................................................................................... 34 6.4.3 Network Settings .................................................................................... 36 6.4.4 Video & Audio Settings ........................................................................... 41 6.4.5 Display Settings ....................................................................................... 43 6.4.6 Event Settings ......................................................................................... 44 6.4.7 Intercom Settings .................................................................................... 47 6.4.8 Access Control Settings ........................................................................... 49 7 Configuration via Client Software ............................................................. 54 7.1 Edit Network Parameters ................................................................................ 54 7.2 Add Device ...................................................................................................... 54 7.2.1 Add Online Device .................................................................................. 54 7.2.2 Add Device by IP Address ....................................................................... 55 7.2.3 Add Device by IP Segment ...................................................................... 55 7.3 Remote Configuration ..................................................................................... 56 7.4 Device Management ....................................................................................... 56 7.5 Organization Management ............................................................................. 56 7.5.1 Add Organization .................................................................................... 56 7.5.2 Modify and Delete Organization ............................................................. 57 7.6 Person Management ....................................................................................... 57 7.6.1 Add Person ............................................................................................. 57 7.6.2 Modify and Delete Person ...................................................................... 59 7.6.3 Import and Export Person Information .................................................. 59 xi Video Intercom D Series Door Station User Manual 7.6.4 Get Person Information from Device ...................................................... 59 7.6.5 Change Person to Other Organization .................................................... 60 7.6.6 Add Person in Batch ................................................................................ 60 7.6.7 Issue Card in Batch ................................................................................. 61 7.6.8 Permission Settings ................................................................................. 62 7.7 Video Intercom Settings .................................................................................. 63 7.7.1 Receive Call from Door Station ............................................................... 63 7.7.2 Live View via Door Station ...................................................................... 64 7.7.3 Release Notice ........................................................................................ 64 7.7.4 Search Video Intercom Information ....................................................... 65 A. Communication Matrix and Device Command ....................................... 67 xii Video Intercom D Series Door Station User Manual 1 Appearance Description Figure 1-1 Appearance of 80 Series Door Station Table 1-1 Descriptions No. Description No. Description Low Illumination Supplement Light Built-in Camera LCD Display Screen Card Reading Area 1 2 3 4 5 Loudspeaker 10 TAMPER Keypad Call Button Microphone Call Center Button 6 7 8 9 1 Video Intercom D Series Door Station User Manual Figure 1-2 Appearance of 81 Series Door Station Table 1-2 Descriptions No. Descripiton No. Description 1 2 3 4 5 Low Illumination Supplement Light Built-in Camera Keypad Call Button Appearance of 30 Series Door Station Call Center Button Microphone Loudspeaker 10 TAMPER LCD Display Screen Card Reading Area 6 7 8 9 2 Video Intercom D Series Door Station User Manual Table 1-3 Descriptions No. Description No. Description 1 2 3 4 5 Low Illumination Supplement Light Loudspeaker LCD Display Screen Card Reading Area Keypad Call Button Call Center Button Microphone TAMPER 6 7 8 9 3 Video Intercom D Series Door Station User Manual 2 Terminal and Wiring Description 2.1 Terminal Description Figure 2-1 Terminal Description Table 2-1 Descriptions Name LAN Interface Description ANALOG Analog Interface Network Interface ALARM IN Door Contact Detection Input 1/Door Contact Door Contact Detection Input 1/Door Contact Door Contact Detection Input 2/Door Contact Door Contact Detection Input 2/Door Contact LAN SEN1 BTN1 SEN2 BTN2 GND AIN1 AIN2 AIN3 AIN4 Grounding Alarm Input 1 Alarm Input 2 Alarm Input 3 Alarm Input 4 4 RS485 485A+
RS-485 Communication Interfaces Video Intercom D Series Door Station User Manual Name Interface Description LOCK1 Door Lock Relay Output (NO) LOCK2 Door Lock Relay Output (NO) Grounding Common Interface Door Lock Relay Output (NC) Common Interface Door Lock Relay Output (NC) Alarm Relay Output 2 ALARM OUT`
AO1+
Alarm Relay Output 1 WIEGAND TAMP Tamper-proof Input of Wiegand Card Reader Card Reader Indicator Output (Valid Card Output) Card Reader Indicator Output (Invalid Card Output) Card Reader Buzzer Output Data Input Interface Wiegand Card Reader: Data 0 Data Input Interface Wiegand Card Reader: Data 1 485A-
GND NO1 COM1 NC1 NO2 COM2 NC2 AO1-
AO2+
AO2-
OK ERR BZ W0 W1 GND RES GND RESERVED Grounding Reserved Grounding 5 Video Intercom D Series Door Station User Manual Name Interface Description RES Reserved POWER 12 VDC DC 12 V Power Supply Input 2.2 Wiring Description 2.2.1 D-Series Door Lock Wiring Figure 2-2 Door Lock Wiring Note Terminal NC1/COM1 is set as default for accessing electric bolt. Terminal NO1/
COM1 is set as default for accessing electric strike. To connect electric lock in terminal NO2/COM2/NC2, it is required to set the output of terminal NO2/COM2/NC2 to be electric lock with iVMS-4200client software. 2.2.2 D-Series Door Contact Wiring (8081 Series) 6 Video Intercom D Series Door Station User Manual Figure 2-3 Door Contact Wiring Note Terminal SEN1/SEN2 can both connect to door contact. 2.2.3 D-Series Exit Button Wiring (8081 Series) 7 Video Intercom D Series Door Station User Manual Figure 2-4 Exit Button Wiring Terminal BTN1/BTN2 can both connect to exit button. 2.2.4 External Card Reader Wiring Please set the DIP switch first before connecting the card reader. If the DIP switch should be configured when the card reader is power-on, please reboot the card reader after configuring the DIP switch. The DIP switch description is shown in the following table:
Table 2-2 DIP Switch Description Note Note No. 1 to 4 6 Description How to Configure Set the RS-485 address ON: 1 OFF: 0 Select Wiegand protocol or RS-485 protocol ON: Wiegand 8 Video Intercom D Series Door Station User Manual No. Description How to Configure 7 Set the Wiegand protocol (It is invalid when setting OFF in 6.) ON: Wiegand 26 OFF: Wiegand 34 OFF: RS-485 RS-485 Card Reader Wiring Figure 2-5 RS-485 Card Reader Wiring Note When card reader is accessed via RS-485, the door station cannot connect to elevator controller. 9 Video Intercom D Series Door Station User Manual Wiegand Card Reader Wiring Figure 2-6 Wiegand Card Reader Wiring 2.2.5 D-Series Elevator Controller Wiring Enter a short description of your concept here (optional). This is the start of your concept. 2.2.6 Alarm Input Device Wiring The alarm input wiring diagram is as follows:
10 Video Intercom D Series Door Station User Manual Figure 2-7 Alarm Input Wiring Diagram 2.2.7 Alarm Output Device Wiring The alarm output wiring diagram is as follows:
11 Video Intercom D Series Door Station User Manual Figure 2-8 Alarm Output Wiring Diagram 12 Video Intercom D Series Door Station User Manual 3 Installation Make sure the device in the package is in good condition and all the assembly parts are included. The power supply the door station support is 12 VDC. Please make sure your power supply matches your door station. Make sure all the related equipment is power-off during the installation. Check the product specification for the installation environment. To install the door station onto the wall, you are required to use a matched gang box. Figure 3-1 Gang Box The dimension of gang box is: 407.5 (W) 135 (H) 55 (D) mm. The dimensions above are for reference only. The actual size can be slightly different from the theoretical dimension. 3.1.2 Flush Mounting with Gang Box Note Steps 1. Drill a hole in the wall for inserting the gang box. The size of the hole should be larger than that of the gang box. The suggested size of the hole is 408 (W) 135.5 (H) 55 (D) mm. 13 Video Intercom D Series Door Station User Manual 2. Insert the gang box into the hole and fix it with 4 PA4 screws. Figure 3-2 Drill an Installation Hole Figure 3-3 Insert the Gang Box 14 Video Intercom D Series Door Station User Manual 3. Make sure the edges of the gang box align to the wall and the hook A and hook B of the gang box hook onto the wall. 4. Route the cables of the door station through the cable hole. 5. Insert the door station into the gang box and then move the door station downward to hook the lock catches on the rear panel onto the hook C of the gang box. 6. Fix the door station with 2 PM3 screws. Figure 3-4 Insert the Door Station 7. After fixing the door station onto the gang box, secure it by inserting the plate and insert 2 POM2 screws. 15 Video Intercom D Series Door Station User Manual To install the door station onto the wall, you are required to use a matched gang box. Figure 3-5 Fix the Door Station Figure 3-6 Gang Box Note The dimension of gang box is: 404 (W) 123 (H) 47.5 (D) mm. The dimensions above are for reference only. The actual size can be slightly different from the theoretical dimension. 16 Video Intercom D Series Door Station User Manual 3.2.2 Flush Mounting with Gang Box Steps 1. Drill a hole in the wal for inserting the gang box. The size of the hole should be larger than that of the gang box. The suggested size of the hole is 404.5 (W) 123.5 (H) 48 (D) mm. Figure 3-7 Drill an Installation Hole 2. Insert the gang box into the hole and fix it with 4 PA4 screws. Make sure the edges of the gang box align to the wall. 3. Route the cables of the door station through the cable hole. Figure 3-8 Insert the Gang Box 17 Video Intercom D Series Door Station User Manual 4. Put the door station into the gang box and hook the lock catches on the rear panel. Figure 3-9 Install the Door Station 5. Pull the door station downward and then push it towards the inside to make sure it fits the hole. 6. Tighten the screws of the door station with the wrench. To install the door station onto the wall, you are required to use a matched gang box. Figure 3-10 Fix the Door Station 18 Video Intercom D Series Door Station User Manual Figure 3-11 Gang Box The dimension of gang box is: 343 (W) 113 (H) 55 (D) mm. The dimensions above are for reference only. The actual size can be slightly different from the theoretical dimension. 3.3.2 Flush Mounting with Gang Box Note Steps 1. Drill a hole in the wall for inserting the gang box. The size of the hole should be larger than that of the gang box. The suggested size of the hole is 343.5 (W) 113.5 (H) 55.5 (D) mm. 19 Video Intercom D Series Door Station User Manual Figure 3-12 Drill an Installation Hole 2. Insert the gang box into the hole and fix it with 4 PA4 screws. 3. Make sure the edges of the gang box align to the wall. 4. Route the cables of the door station through the cable hole. 5. Put the door station into the gang box. 6. Fix the door station to the gang box with 4 screws. 20 Video Intercom D Series Door Station User Manual Figure 3-13 Fix the Door Station 21 Video Intercom D Series Door Station User Manual 4 Activation 4.1 Activate Device Locally You are required to activate the device first by settings a strong password for it before you can use the device. Steps 1. Power on the device to enter the activation page automatically. 2. Create a password and confirm it. Table 4-1 Number Button Description No. Description No. Description Hold 0 to enter special characters. Table 4-2 Number Button Description No. Description No. Description 1 2 3 4 5 1 2 3 4 5 1,.?! -*#
2abcABC 3defDEF 4ghiGHI 5jklJKL 1,.#?
2!@%
3^$*
4( )\
5&/-
6mnoMNO 7pqrsPQRS 8tuvTUV 9wxyzWXYZ 0 6_=+
7[];:
8"|<
9>{}
6 7 8 9 0 6 7 8 9 22 Video Intercom D Series Door Station User Manual Note The password required 8 to 16 characters. The way to enter the password, take button 2 as an example: Press 2 to enter the number '2' or hold 2 for 1.5 s and press 2 again to enter the character 'a'. When you have entered the password, press # to switch to confirm the password. Press * to delete the wrong charater. 3. Press # to activate. 4.2 Activate Device via Client Software You can only configure and operate the door station after creating a password for the device activation. Default parameters of door station are as follows:
Default IP Address: 192.0.0.65. Default Port No.: 8000. Default User Name: admin. Steps 1. Run the client software, click Maintenance and Management Device Management Device to enter the page. 2. Click Online Device. 3. Select an inactivated device and click Activate. 4. Create a password, and confirm the password. Note We highly recommend you to create a strong password of your own choosing
(using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you change your password regularly, especially in the high security system, changing the password monthly or weekly can better protect your product. 5. Click OK to activate the device. 23 Video Intercom D Series Door Station User Manual Note When the device is not activated, the basic operation and remote operation of device cannot be performed. You can hold the Ctrl or Shift key to select multiple devices in the online devices, and click the Activate button to activate devices in batch. 4.3 Activate Device via Web You are required to activate the device first by setting a strong password for it before you can use the device. Default parameters of the door station are as follows:
Default IP Address: 192.0.0.65. Default Port No.: 8000. Default User Name: admin Steps enter the activation page. Note 1. Power on the device, and connect the device to the network. 2. Enter the IP address into the address bar of the web browser, and click Enter to The computer and the device should belong to the same subnet. 3. Create and enter a password into the password field. 4. Confirm the password. 5. Click OK to activate the device. 24 Video Intercom D Series Door Station User Manual 5 Local Operation 5.1 Local Configuration 5.1.1 Edit Network Parameters After activating, you should edit the network parameters. Steps 1. Hold * and # at the same time to enter the authentication page. 2. Authenticate via administrator.
Authenticate face/card/fingerprint to login. Press # to enter the password to login. 3. Swritch to Network settings according to the tips on the page. Press # to enter the settings page. 4. Edit the parameters according to your needs. 5. Press * to save and exit. 5.1.2 Door Station Settings Edit the parameters of the door station (including but not limited to, community No., building No., floor No., room No. and device mode). 1. Configure the parameters according to the actual needs. Outer door station can only edit the Community No., Project No. and No. The No. of the main door station is 0. The No. of sub door stations should be larger than 0 and ranges from 1 to 99. Each unit should add 1 main door station. Up to 8 sub door stations can be added to the main door station. Note Steps 2. Optional: Adjust the brightness of the screen. 3. Optional: Enable the Channel Mode according to your needs. 4. Optional: Select the language. 25 Video Intercom D Series Door Station User Manual 5. After configuration, press * to save and exit. 5.1.3 Add Residents User Management Steps You can add, edit and delete the informations of the users. 1. Hold * and # at the same time to enter the authentication page. 2. Authenticate via administrator.
Authenticate face/card/fingerprint to login. Press # to enter the password to login. 3. Switch to User Management according to the tips on the page. 4. Press # to enter the settings page. Add Users Steps You can add cards, face pictures, fingerprints, permissions and room No. for the users. 1. Select +Add, and press # to enter the adding page. 2. Edit the room No. 3. Add cards. 1) Switch to the card and press #. 3) Press # to add. 4. Add face pictures. 1) Switch to the face and press #. 2) Press # to capture. Press # again to save. 2) Enter the card No. manually or present the card on the card reading area to get the card No. automatically. 26 Video Intercom D Series Door Station User Manual Press * to capture again. Note model. Up to 5000 face pictures can be added to the device. Refers to the actual Each user can add one face picture only. 5. Add fingerprints. 1) Switch to the fingerprint and press #. 2) Select +Add Fingerprint and press # to add. 3) Put your finger on the fingerprint recognition area. 4) Press * to save and exit. Note Up to 10 fingerprints can be added to the same user. 6. Switch to the permisson and press # to set. 7. Press * to save and exit. 5.1.4 About Steps You can view the device model, system version and QR Code of the device. 1. Hold * and # at the same time to enter the authentication page. 2. Authenticate via administrator.
Authenticate face/card/fingerprint to login. Press # to enter the password to login. 3. Swritch to About according to the tips on the page. 4. Press # to enter the page. 5.2 Video Intercom Operation 5.2.1 Call Resident The door station can work as main/sub door station, and outer door station, which correspond to different calling resident modes respectively. 27 Video Intercom D Series Door Station User Manual Call Resident from Main/Sub Door Station Press any digit button on the main/sub door station page to enter the calling page. Enter the room No. and press call button. Call Resident from Outer Door Station Press call button on the outer door station page to enter the calling page . Enter Building No. + # + Unit No. + # + Room No. and press call button to call resident. 5.2.2 Call Center Press any digit button on the main/sub door station page to enter the calling page. Press center button to call., and press * to cancel during calling management center. 5.3 Unlock Door 5.3.1 Unlock by Password Unlock by Common Password Unlock by Public Password Note Press any digit button on the main/sub door station page to enter the calling page. Enter # + Room No. + Common Password + #to unlock the door. Make sure you have created the public password via iVMS-4200 Client Software remotely. Press any digit button on the main/sub door station page to enter the calling page. 28 Video Intercom D Series Door Station User Manual Enter # + Public Password + #to unlock the door. 5.3.2 Unlock by Presenting Card Make sure you have issued the card to the device. Present the card on the card reading area to unlock. You cannot unlock the door by presenting the main card. 5.3.3 Unlock by Fingerprint Note Note Note Make sure you have added the fingerprint to the device. Fingerprint function may vary with different modules. Please refer to the actual devices. Put your finger on the finger recognition module to unlock. 5.3.4 Unlock by QR Code The device supports unlocking by QR code. You can use the camera to scan the QR code which is created via mobile client. Steps Note station. Make sure the door station has been added to the indoor station. Make sure the indoor station is connected to Wi-Fi. Make sure the door station has issued the card and connected to the indoor 1. Search and install the Hik-Connect to your mobile phone. 2. Register and login the client according to the notice on the page. 3. Scan the QR code/bar code on the device or enter the serial No. manually to add the indoor station. 4. Create a QR code. 29 Video Intercom D Series Door Station User Manual 5. Press Scan QR Code on the main page to enter the scanning page. 6. Use the camera to scan the QR code. Note Choose a location that will not reflect light when installing the door station, and tear off surface film of the acrylic door station. Align the QR code with the camera horizontally when scanning the QR code. QR code scanning is not supported at night. 30 Video Intercom D Series Door Station User Manual 6 Remote Configuration via Web 6.1 Live View In the browser address bar, enter the IP address of the device, and press the Enter key to enter the login page. Enter the user name and password and click Login to enter the Live View page. Or you can click Live View to enter the page. Figure 6-1 Live View You can start/stop live view, capture, record, audio on/off, two-way audio, etc. The stream type can be set as main stream or sub stream. For IE (Internet Explorer) or Google users, the device support two-way audio communication. 6.2 User Management You can add, delete or search the information of the user. Click User to enter the settings page. Click Add and enter the username, floor No. and room No. to add. Click Edit to modify the informations of the user. Check the box of the user and click Delete to delete the selected user. Enter the keyword and click Search. The information will display in the list. 31 Video Intercom D Series Door Station User Manual 6.3 Device Management You can manage the linked device on the page. Click Device List to enter the settings page. Add Device Click Add to add the indoor station or sub door station. Enter the parameters and click OK to add. Click Import. Enter the information of the device in the template to import devices in batch. Click Export to export the information to the PC. Export Upgrade Click Upload Package to select the upgrade package. Click Timing Upgrading, slide Enable auto-upgrade to set the start time and end time. The device will upgrade from start time to end time automatically. Click Upgrading Status to view the version fo the device. 6.4 Parameters Settings Click Configuration to set the parameters of the device. Remote configuration in iVMS-4200 and Batch Configuration Tool is the same as that in Web. Here takes the configuration in web for example. Internet Options Security to disable the Protected Note Run the browser, click Mode. 6.4.1 Local Parameters Settings 32 Video Intercom D Series Door Station User Manual You can configure the parameters of the live view, record files and captured pictures. The record files and captured pictures are the ones you record and capture by using the web browser. You can also set and view the saving paths of the captured pictures and recorded videos on the PC that running the web browser. Live View Parameters Stream Type Play Performance Set the stream type as Main Stream or Sub-stream. Set the live view performance to Shortest Delay, Balanced or Fluent. Auto Start Live View Check Yes to enable the function. Image Format Select the image format for picture capture. Click Save to enable the settings. Record File Parameters Record File Size Select the packed size of the manually recorded and downloaded video files to 256M, 512M or 1G. After the selection, the maximum record file size is the value you selected. Save record files to Set the saving path for the manually recorded video files. Click Save to enable the settings. Picture and Clip Settings Save snapshots in live view to Note Set the saving path of the manually captured pictures in live view mode. You can click Browse to change the directory for saving the clips and pictures, and click Open to open the set folder of clips and picture saving. Click Save to enable the settings. 33 Video Intercom D Series Door Station User Manual 6.4.2 System Settings Follow the instructions below to configure the system settings, include System Settings, Maintenance, Security, and User Management, etc. Click System to enter the settings page. Basic Information Click System Settings Basic Information to enter the settings page. On the page, you can edit Device Name and Device No. Set the Language and System Type according to your needs. Click Save to enable the settings. Time Settings Click System Settings Time Settings to enter the settings page. Select the Time Zone of your location from the drop-down list. Enable NTP, set the Server Address, NTP Port and Interval. Enable Manual Time Sync., set the time manually or check the Sync. with computer time. Click Save to enable the settings. Click System Settings DST to enable DST. Set the parameters according to your needs and click Save to enable the settings. DST Maintenance Click Maintenance Upgrade & Maintenance to enter the settings page. 34 Video Intercom D Series Door Station User Manual Reboot: Click Reboot to reboot the device. Figure 6-2 Maintenance Restore Default Click Restore to reset all the parameters, except the IP parameters and user information, to the default settings. Click Default to restore all parameters to default settings. Export parameters:
1. Click Device Parameters to pop up the dialog box. 2. Set and confirm the encryption password. 3. Click OK to export parameters. Import Config. File:
1. Click Browse to select the configuration file. 2. Click Import and enter the encryption password to import. Upgrade: Click Browse to select the upgrade file. Note The upgrading process will last 1 to 10 minutes, do not power off during the upgrading. The device reboots automatically after upgrading. User Management Click User Management to enter the settings page. Administrator can edit the permission for the users. 35 Video Intercom D Series Door Station User Manual Note We highly recommend you to create a strong password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you change your password regularly, especially in the high security system, changing the password monthly or weekly can better protect your product. Online Users Click User Management Online Users to enter the page. Click Refresh to get the present information. Figure 6-3 Online Users Arming/Disarming Information Click User Management Arming/Disarming Information to view the information. Click Refresh to get the present information. 6.4.3 Network Settings TCP/IP Settings TCP/IP settings must be properly configured before you operate the device over network. The device supports IPv4. Steps 1. Click Network Basic Settings TCP/IP to enter the settings page. 36 Video Intercom D Series Door Station User Manual Figure 6-4 TCP/IP Settings 2. Configure the network parameters.
Check DHCP, the device will get the parameters automatically. Set the IPv4 Address, IPv4 Subnet Mask and IPv4 Default Gateway manually. 3. Configure the DNS server. 4. Click Save to enable the settings. Port Settings Steps 1. Click Network Basic Settings Port to enter the settings page. Figure 6-5 Port Settings 2. Set the ports of the device. HTTP Port The default port number is 80, and it can be changed to any port No. which is not occupied. RTSP Port 37 Video Intercom D Series Door Station User Manual The default port number is 554 and it can be changed to any port No. ranges from 1 to 65535. The default server port number is 8000, and it can be changed to any port No. ranges from 2000 to 65535. 3. Click Save to enable the settings. Server Port SIP Setting Steps 1. Click Network Basic Settings SIP to enter the settings page. 2. Check Enable VOIP Gateway. 3. Configure the SIP parameters. 4. Click Save to enable the settings. SNMP Settings Before You Start Before setting the SNMP, please download the SNMP software and manage to receive the camera information via SNMP port. By setting the Trap Address, the camera can send the alarm event and exception messages to the surveillance center. Steps 1. Click Network Advanced Settings SNMP to enter the settings page. 38 Video Intercom D Series Door Station User Manual 2. Check the checkbox of Enable SNMPv1, Enable SNMP v2c, Enable SNMPv3 to Figure 6-6 SNMP Settings To lower the risk of information leakage, you are suggested to enable SNMP v3 instead of SNMP v1 or v2. enable the feature correspondingly. 3. Configure the SNMP settings. 4. Click Save to enable the settings. Note FTP Settings 39 Video Intercom D Series Door Station User Manual Steps 1. Click Network Advanced Settings FTP to enter the settings page. Figure 6-7 FTP Settings 2. Check Enable FTP. 3. Select Server Type. 4. Input the Server IP Address and Port. 5. Configure the FTP Settings, and the user name and password are required for the server login. 6. Set the Directory Structure, Parent Directory and Child Directory. 7. Set the picture naming rules. 8. Click Save to enable the settings. 40 Video Intercom D Series Door Station User Manual 6.4.4 Video & Audio Settings Video Parameters Steps 1. Click Video/Audio Video to enter the settings page. Figure 6-8 Video Parameters 2. Select the Stream Type. 3. Configure the video parameters. Select the stream type to main stream or sub stream. Stream Type Video Type Resolution Select the stream type to video stream, or video & audio composite stream. The audio signal will be recorded only when the Video Type is Video &
Audio. 41 Video Intercom D Series Door Station User Manual Select the resolution of the video output. Select the bitrate type to constant or variable. Bitrate Type Video Quality Frame Rate Max. Bitrate When bitrate type is selected as Variable, 6 levels of video quality are selectable. Set the frame rate. The frame rate is to describe the frequency at which the video stream is updated and it is measured by frames per second (fps). A higher frame rate is advantageous when there is movement in the video stream, as it maintains image quality throughout. Set the max. bitrate from 32 to 16384 Kbps. The higher value corresponds to the higher video quality, but the better bandwidth is required. Video Encoding I Frame Interval The device supports H.264. Set I Frame Interval from 1 to 400. 4. Click Save to save the settings. Audio Parameters Steps 1. Click Video/Audio Audio to enter the settings page. 2. Configure the stream type and the audio encoding type. Figure 6-9 Audio Settings 42 Video Intercom D Series Door Station User Manual Stream Type Audio Encoding Select the stream type to main stream or sub stream. The device support G.711ulaw and G.711 alaw. 3. Adjust the Input Volume, Output Volume and Speak Volume. Note Available range of volume: 0 to 10. 4. Click Save to save the settings. 6.4.5 Display Settings Configure the image adjustment, backlight settings and other parameters in display settings. Steps 1. Click Image Display Settings to enter the display settings page. Figure 6-10 Display Settings 2. Select the Format. 3. Set the display parameters. WDR Brightness Wide Dynamic Range can be used when there is a high contrast of the bright area and the dark area of the scene. 43 Video Intercom D Series Door Station User Manual Brightness describes bright of the image, which ranges from 1 to 100. Contrast Saturation Sharpness BLC Area Contrast describes the contrast of the image, which ranges from 1 to 100. Saturation describes the colorfulness of the image color, which ranges from 1 to 100. Sharpness describes the edge contrast of the image, which ranges from 1 to 100. If you focus on an object against strong backlight, the object will be too dark to be seen clearly. BLC compensates light to the object in the front to make it clear. OFF, Up, Down, Left, Right and Center are selectable. 4. Click Save to enable the settings. 6.4.6 Event Settings Motion Detection Motion detection detects the moving objects in the configured surveillance area, and a series of actions can be taken when the alarm is triggered. Steps 1. Click Event Motion to enter the settings page. 44 Video Intercom D Series Door Station User Manual 2. Check Enable Motion Detection to enable the function. Figure 6-11 Motion Detection 3. Click Draw Area.Click and drag the mouse on the live video to draw a motion detection area. Click Stop Drawing to finish drawing one area. Click Save to save the settings. Clear Area Click Clear All to clear all of the areas. Adjust Sensitivity Move the slider to set the sensitivity of the detection. 4. Click Arming Schedule to edit the arming schedule. 5. Click on the time bar and drag the mouse to select the time period. Click Save to save the settings. Delete Schedule Click Delete to delete the current arming schedule. 6. Click Linkage Method to enable the linkages. 45 Video Intercom D Series Door Station User Manual Notify Surveillance Center Send an exception or alarm signal to the remote management software when an event occurs. 7. Click Save to enable the settings. Set Video Tampering Alarm Steps 2. Check Enable Video Tampering. 3. Draw area. 1) Click Area Settings. When the configured area is covered and cannot be monitored normally, the alarm is triggered and the device takes certain alarm response actions. 1. Click Event Basic Event Video Tampering to enter the settings page. 2) Click
, and drag the mouse in the live view page to draw an area. 3) Optional: Click to clear the drawing area. 4. Drag the block to set the Sensitivity. The higher the value is, the easier to detect the area covering. 5. Optional: Click Linkage Method, and check the normal linkage or notify surveillance center according to your actual needs. Normal Linkage Set the normal alarm linkage. Notify Surveillance Center The alarm information is uploaded to the surveillance center when an alarm event is detected. 6. Optional: Click or to perform the record or capture operation. 7. Click Save to save the settings. Event Linkage Steps 1. Click Event Basic Event Event Linkage to enter the settings page. 46 Video Intercom D Series Door Station User Manual Figure 6-12 Event Linkage 2. Select the Major Type as Device Event or Door Event. 3. Select the type of the Normal Linkage for the event. 4. Click Save to enable the settings. 6.4.7 Intercom Settings Device ID Configuration 47 Video Intercom D Series Door Station User Manual Steps 1. Click Device ID Settings to enter the page. 2. Select the device type from the drop-down list, and set the corresponding Figure 6-13 Device ID Settings 3. Click Save to enable the device number configuration. information. Note For main door station (D series or V series), the serial No. is 0. For sub door station (D series or V series), the serial No. cannot be 0. Serial No. ranges from 1 to 99. For each villa or building, at least one main door station (D series or V series) should be configured, and one sub door stations (D series or V series) can be customized. For one main door station (D series or V series), up to 8 sub door stations can be configured. Linked Network Settings Steps 1. Click Intercom Linked Network Settings to enter the settings page. 48 Video Intercom D Series Door Station User Manual Figure 6-14 Linked Network Settings 2. Set the master station IP address and master station SIP cllient Port. 3. Set the private SIP server IP address and private SIP Server Port. 4. Set the SIP Client Port. 5. Enter the password. 6. Click Save to enable the settings. Time Parameters Click Intercom Time Parameters to enter the page. Configure the time parameters and click Save. Note Maximum speaking time varies from 90s to 120s, and maximum message time varies from 30s to 60s. 6.4.8 Access Control Settings 49 Video Intercom D Series Door Station User Manual Permission Password Steps 1. Click Access Control Permission Password to enter the settings page. Figure 6-15 Permission Password 2. Select the password type. 3. Change the password. 4. Set the number of doorphone. 5. Click Save to enable the settings. Door Parameters Steps 1. Click Access Control Door Parameters to enter the settings page. Figure 6-16 Door Parameters 50 Video Intercom D Series Door Station User Manual 2. Select the door and edit the door name. 3. Set door contact status. 4. Set lock action time. 5. Click Save to enable the settings. Click Access Control Card Security to enter the settings page. Slide to enable card encryption parameters. Click Save to enable the settings. Card Security Elevator Control Before You Start Make sure your door station is in the mode of main door station. Only the main door station support elevator control function. Make sure your door station has been connected to the elevator controller via RS-485 wire if you want to use RS-485 interface. Steps configuration page. 1. Click Access Control Elevator Control to enter the corresponding 51 Video Intercom D Series Door Station User Manual 2. Check to enable elevator control function. Figure 6-17 Elevator Control 3. Select an Elevator No., and select an elevator controller type for the elevator. 4. Set the Negative Floor. 5. Select the Interface Type as RS-485 or Network Interface. And enable the elevator control.
If you select RS-485, make sure you have connected the door station to the elevator controller with RS-485 wire. If you select Network interface, enter the elevator controller's IP address, port No., user name, and password.
6. Click Save to enable the settings. Note Up to 4 elevator controllers can be connected to one door station. Up to 10 negative floors can be added. Make sure the interface types of elevator controllers, which are connected to the same door station are consistent. 52 Video Intercom D Series Door Station User Manual RS-485 Settings Set the working mode to linked device. Steps 1. Click Access Control RS485 Settings to enter the settings page. Figure 6-18 RS-485 Settings 2. Select the No. 3. Select the working mode. 4. Click Save to enable the settings. 53 Video Intercom D Series Door Station User Manual 7 Configuration via Client Software 7.1 Edit Network Parameters To operate and configure the device via LAN (Local Area Network), you need connect the device in the same subnet with your PC. You can edit network parameters via iVMS-4200 client software. 1. Select an online activated device and click the Modify Netinfo. 2. Edit the device IP address and gateway address to the same subnet with your 3. Enter the password and click OK to save the network parameters modification. The default port No. is 8000. The default IP address of the door station is 192.0.0.65. After editing the network parameters of device, you should add the devices to the device list again. Steps computer. Note You should add device to the software so as to configure the device remotely. 7.2 Add Device 7.2.1 Add Online Device Before You Start Make sure the device to be added is in the same subnet with your computer. Otherwise, please edit network parameters first. 1. Click Online Device to select an active online device. Steps 2. Click Add. 3. Enter corresponding information, and click Add. 54 Video Intercom D Series Door Station User Manual Figure 7-1 Add to the Client 1. Click +Add to pop up the adding devices dialog box. 7.2.2 Add Device by IP Address Steps 2. Select IP/Domain as Adding Mode. 3. Enter corresponding information. 4. Click Add. 7.2.3 Add Device by IP Segment 55 Video Intercom D Series Door Station User Manual You can add many devices at once whose IP addresses are among the IP segment. Steps 1. Click +Add to pop up the dialog box. 2. Select IP Segment as Adding Mode. 3. Enter corresponding information, and click Add. 7.3 Remote Configuration Select the device, click to configure the parameters remotely. 7.4 Device Management Device management includes device activation, adding device, editing device, and deleting device, and so on. After running the iVMS-4200, video intercom devices should be added to the client software for remote configuration and management. 7.5 Organization Management On the main page of the Client Software, click the configuration page. PersonalManagement to enter 7.5.1 Add Organization Steps 1. In the organization list on the left, click +Add. 2. Enter the Organization Name as desired. 3. Click OK to save the adding. 4. Optional: You can add multiple levels of organizations according to the actual needs. organization. 1) You can add multiple levels of organizations according to the actual needs. 2) Then the added organization will be the sub-organization of the upper-level 56 Video Intercom D Series Door Station User Manual Note Up to 10 levels of organizations can be created. 7.5.2 Modify and Delete Organization You can select the added organization and click to modify its name. You can select an organization, and click X button to delete it. Note The lower-level organizations will be deleted as well if you delete an organization. Make sure there is no person added under the organization, or the organization cannot be deleted. 7.6 Person Management After adding the organization, you can add person to the organization and manage the added person such as issuing cards in batch, importing and exporting person's information in batch, etc. Note Up to 10,000 persons or cards can be added. 7.6.1 Add Person Steps Note Person information is necessary for the video intercom system. And when you set linked device for the person, the intercom between intercom devices can be realized. 1. Select an organization in the organization list and click Add on the Person panel to pop up the adding person dialog. The Person No. will be generated automatically and is editable. 2. Set basic person information. 57 Video Intercom D Series Door Station User Manual 1) Enter basic information: name, gender, tel, birthday details, effective period and email address. The length of person name should be less than 15 characters. 2) Click Add face to upload the photo. Note Note The picture should be in *.jpg format. Click Upload Select the person picture from the local PC to upload it to the client. Click Take Phone Take the person's photo with the PC camera. Take the person's photo with the collection device. Click Remote Collection 3. Issue the card for the person. 1) Click Credential Card . 2) Click + to pop up the Add Card dialog. 3) Select Normal Card as Card Type. 4) Enter the Card No. 5) Click Read and the card(s) will be issued to the person. 4. Link the device to the person. 1) Set the linked devices. Linked Device You can bind the indoor station to the person. Note If you select Analog Indoor Station in the Linked Device, the Door Station field will display and you are required to select the door station to communicate with the analog indoor station. Room No. You can enter the room No. of the person. 2) Click OK to save the settings. 5. Click Add to save the settings. 58 Video Intercom D Series Door Station User Manual 7.6.2 Modify and Delete Person Select the person and click Edit to open the editing person dialog. To delete the person, select a person and click Delete to delete it. Note If a card is issued to the current person, the linkage will be invalid after the person is deleted. 7.6.3 Import and Export Person Information The person information can be imported and exported in batch. Steps to the local PC. dialog. 1. Exporting Person: You can export the added persons' information in Excel format 1) After adding the person, you can click Export Person to pop up the following 2) Click ... to select the path of saving the exported Excel file. 3) Check the checkboxes to select the person information to export. 4) Click OK to start exporting. 2. Importing Person: You can import the Excel file with persons information in batch from the local PC. 1) Click Import Person. template first. 2) You can click Download Template for Importing Person to download the 3) Input the person information to the downloaded template. 4) Click ... to select the Excel file with person information. 5) Click OK to start importing. 7.6.4 Get Person Information from Device If the added device has been configured with person information (including person details, fingerprint, issued card information), you can get the person information from the device and import to the client for further operation. 59 Video Intercom D Series Door Station User Manual Steps Note This function is only supported by the device the connection mothod of which is TCP/IP when adding the device. 1. In the organization list on the left, click to select an organization to import the persons. 2. Click Get from Device to pop up the dialog box. 3. The added device will be displayed. 4. Click to select the device and then click Get to start getting the person information from the device. Note The person information, including person details, person's fingerprint information (if configured), and the linked card (if configured), will be imported to the selected organization. If the person name stored in the device is empty, the person name will be filled with the issued card No. after importing to the client. The gender of the persons will be Male by default. 7.6.5 Change Person to Other Organization You can move the person to another organization if needed. Steps 1. Select the person in the list and click Change Organization. 2. Select the organization to move the person to. 3. Click OK to save the settings. 7.6.6 Add Person in Batch Enter a short description of your task here (optional). Before You Start Enter the prerequisites here (optional). Enter the context of your task here (optional). Steps 1. Enter your first step here. 60 Video Intercom D Series Door Station User Manual Enter the result of your step here (optional). Example Enter an example that illustrates the current task (optional). What to do next Enter the tasks the user should do after finishing this task (optional). 7.6.7 Issue Card in Batch Steps You can issue multiple cards for the person with no card issued in batch. 1. Click Batch Issue Cards to enter the dialog page. All the added person with no card issued will display in the Person(s) with No Card Issued list. 2. Click Settings. Figure 7-2 Issue Card in Batch 61 Video Intercom D Series Door Station User Manual Figure 7-3 Card Settings 3. Select Card Type and Card No. Type. 4. Click OK to save the settings. Result After issuing the card to the person, the person and card information will display in the Person(s) with Card Issued list. 1. On the main page, click AccessControlInfo Access Group to enter the 7.6.8 Permission Settings Add Permissions Steps page. 2. Click +Add to pop up the adding dialog box. 3. Configure the parameters. 1) Enter the Name of the permission. 62 Video Intercom D Series Door Station User Manual 2) Select the Template of the schedule. 3) Check the person to Selected according to your needs. 4) Check the device to Selected according to your needs. 4. Click Save. 5. Check the permission and click Apply All to Device. The status of the permission displays as Applied. 6. Optional: Click Applying Status to check the details. Modify/Delete Permissions On the page of the permission settings, click permission. to edit the parameters of the Select one or more permissions, click Delete to remove the permissions. 7.7 Video Intercom Settings The Video Intercom Management module provides the function of video intercom, checking call logs and managing notice via the iVMS-4200 Client Software. Note For the user with access control module permissions, the user can enter the Access Control module and manage video intercom and search information. You should add the device to the software and configure the person to link the device in Access Control module before your configuration remotely. On the main page, click Intercom on the left bar to enter the Video Intercom page. AccessControlInfo Video Intercom Video 7.7.1 Receive Call from Door Station Steps 1. Select the client software in the device page to start calling the iVMS-4200 Client Software and an incoming call dialog will pop up in the client software. 2. Click Answer to answer the call. Or click Hang Up to decline the call. 3. After you answer the call, you will enter the In Call window. 63 Video Intercom D Series Door Station User Manual Click to adjust the volume of the loudspeaker. Click to adjust the volume of the microphone. Click Hang Up to hang up the dialog. Click to open the door remotely. Note One video intercom device can only connect with one client software. The maximum ring duration can be set from 15s to 60s via the Remote Configuration of the video intercom device. The maximum speaking duration between indoor station and iVMS-4200 can be set from 120s to 600s via the Remote Configuration of indoor station. The maximum speaking duration between door station and iVMS-4200 can be set from 90s to 120s via the Remote Configuration of door station. 7.7.2 Live View via Door Station Steps page. 1. On the main page of the client software, click Main View to enter the Live View 2. In the left list of the window, double-click the device IP or click the play icon to live view. 3. Optional: On the Live View page, control-click and select Capture to get the picture of the live view. 7.7.3 Release Notice You can create different types of notices and send them to the residents. Four notice types are available, including Advertising, Property, Alarm and Notice Information. Before You Start Make sure the person has been added to the client. Steps 1. On the video intercom settings page, click Notice to enter the page. 2. Click +Add to pop up the adding dialog box. 3. Select the person according to your needs. 64 Video Intercom D Series Door Station User Manual 4. Edit the Subject, Type and Information. 5. Click View to select the picture. 6. Click Send. Note Up to 63 characters are allowed in the Subject field. Up to 6 pictures in the JPGE format can be added to one notice. And the maximum size of one picture is 512KB. Up to 1023 characters are allowed in the Information field. 7.7.4 Search Video Intercom Information Search Call Logs Steps 1. On the Video Intercom page, click Call Log to enter the page. 2. Set the search conditions, including call status, device type, start time and end Figure 7-4 Search Call Logs time. Call Status Device Type Click to unfold the drop-down list and select the call status as Dialed, Received or Missed. Or select All to search logs with all statuses. 65 Video Intercom D Series Door Station User Manual Click to unfold the drop-down list and select the device type as Indoor Station, Door Station, Outer Door Station or Analog Indoor Station. Or select All Devices to search logs with all device types. Start Time/End Time Click the time icon to specify the start time and end time of a time period to search the logs. Reset the Settings Click Reset to reset all the configured search conditions. 3. Click Search and all the matched call logs will display on this page. 4. Optional: Check the detailed information of searched call logs, such as call status, ring/speaking duration, device name, resident organization, etc. 5. Optional: Input keywords in the Search field to filter the desired log. 6. Optional: Click Export to export the call logs to your PC. Search Notice Steps Type 1. On the Video Intercom page, click Notice to enter the page. 2. Set the search conditions, including notice type, start time and end time. Select Advertising Information, Property Information, Alarm Information or Notice Information as Type according to your needs. Start Time/End Time Click the time icon to specify the start time and end time of a time period to search the logs. Reset the Settings Click Reset to reset all the configured search conditiions. 3. Click Search and the matched notice will display on this page. 4. Optional: Click Export to export the notices to your PC. 66 Video Intercom D Series Door Station User Manual A. Communication Matrix and Device Command Communication Matrix Scan the following QR code to get the device communication matrix. Note that the matrix contains all communication ports of Hikvision access control and video intercom devices. Figure A-1 QR Code of Communication Matrix Device Command Scan the following QR code to get the device common serial port commands. Note that the command list contains all commonly used serial ports commands for all Hikvision access control and video intercom devices. Figure A-2 Device Command 67 UD19922B
1 | Label | ID Label/Location Info | 88.24 KiB | August 07 2020 |
HIKVISION Door Station Model: DS-KD8023-E6 moavmta I ILIINIATTUMMIIT AN renemn*
Vertenen Case: ABcnEr 0018 TCCIDZADTDADINEEG C2DeBADBtZs This device complies with Part 15 ofthe FCC Rules. Operation is subject to the following two conditions:
(tithis device may not cause harmful interference, and
{Qithis device must accept any interference received, including interference that may cause undesired operation mz Manufacturer: Hangzhou Hikvision Digital Technology Co. Ltd.
" Address: No.555 Qianmo Road, Binjiang District Hangzhou 310052, China
1 | Applicant Declaration Letter | Cover Letter(s) | 128.94 KiB | August 07 2020 |
a) b) c) d) e) f) g) Title:
SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Declaration Applicant Legal Business Name Hangzhou Hikvision Digital Technology Co., Ltd. No. 555 Qianmo Road, Binjiang District Hangzhou 310052, China Address Grantee Code FCC ID Contact Email Contact Phone Authorized Contact Name Xiuying Zhang 2ADTD 2ADTD-KD8023E6 zhangxiuying@hikvision.com
+86-571-88075998 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare;
in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for:
labeling the equipment with the exact FCC ID as specified in this application,
(1)
(2) compliance statement labeling pursuant to the applicable rules,
(3) compliance of the equipment with the applicable technical rules, if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCCs technical requirements. in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. in accordance with ISO17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements.
(1)
(2)
(3) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. the Applicant shall, upon request by SGS, at the Applicants expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a party for these purposes. the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Date:2020/7/30 Applicant Signature:
Print Name:
Xiuying Zhang Senior Certification engineer
*NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database Applicant Declaration Rev:0.0
1 | Power of Attorney Letter | Cover Letter(s) | 39.42 KiB | August 07 2020 |
Hangzhou Hikvision Digital Technology Co., Ltd. TO:
Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Date: 2020-07-30 Regarding: FCC ID: 2ADTD-KD8023E6 To whom it may concern:
We, the undersigned, hereby authorize Parlam Zhan to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with Hangzhou Hikvision Digital Technology Co., Ltd. This authorization is valid until further written notice from the applicant. Name (Printed): Xiuying Zhang Title: Senior Certification engineer Signature:
On behalf of Company: Hangzhou Hikvision Digital Technology Co., Ltd. Telephone: +86-0571-88075998-62460
1 | confidentiality request | Cover Letter(s) | 87.74 KiB | August 07 2020 |
Confidentiality Request regarding application for FCC ID: 2ADTD-KD8023E6 No. 555 Qianmo Road, Binjiang District, angzhou 310052, China SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States Hangzhou Hikvision Digital Technology Co., Ltd. To:
From: Hangzhou Hikvision Digital Technology Co., Ltd. Regarding:
LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commissions rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. Sincerely, Signature:
Printed Name (on file with the FCC associated with the Grantee Code): Xiuying Zhang Title: Senior Certification engineer Company Name: Hangzhou Hikvision Digital Technology Co., Ltd.
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2020-08-07 | 13.56 ~ 13.56 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2020-08-07
|
||||
1 | Applicant's complete, legal business name |
Hangzhou Hikvision Digital Technology Co., Ltd.
|
||||
1 | FCC Registration Number (FRN) |
0024149825
|
||||
1 | Physical Address |
No. 555 Qianmo Road, Binjiang District
|
||||
1 |
Hangzhou, N/A
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
U******@SGS.COM
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2ADTD
|
||||
1 | Equipment Product Code |
KD8023E6
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
X******** Z******
|
||||
1 | Telephone Number |
+86-5********
|
||||
1 | Fax Number |
+86-5********
|
||||
1 |
z******@hikvision.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
SGS-CSTC Standards Technical Services Co., Ltd.
|
||||
1 | Name |
P****** Z********
|
||||
1 | Physical Address |
588 West Jindu Road, Xinqiao, Songjiang
|
||||
1 |
ShangHai, 201612
|
|||||
1 |
China
|
|||||
1 | Telephone Number |
86 21********
|
||||
1 | Fax Number |
86 21********
|
||||
1 |
P******@sgs.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Door Station | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
SGS-CSTC Standards Technical Services Co.,Ltd.
|
||||
1 | Name |
L****** Y****
|
||||
1 | Telephone Number |
+86 (********
|
||||
1 |
l******@sgs.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 13.56000000 | 13.56000000 |