DS-PDD12-EG2 12 m Pet Immune Dual-Tech Detector 1 Disassembling the Detector 2 The Printed Circuit BoardPCB Installation Method - Detector Backplane Installation
(d) PCB
(b) AND/OR Mode
(d) Microwave Module 2 4
(e) Tamper Resisitor Headers 1K,2K2, 4K7,5K6
(c) 50Hz as default 60Hz remove header
(a) PIR Sensor
(f) Terminals
(g) Alarm Resistor Headers 1K, 2K2, 4K7, 5K6, 6K8 3 1
(a) Lens
(b) LED Light Pipe 2019 Hangzhou Hikvision Digital Technology Co., Ltd. It includes instructions on how to use the Product. The software embodied in the Product is governed by the user license agreement covering that Product. About this Manual This Manual is subject to domestic and international copyright protection. Hangzhou Hikvision Digital Technology Co., Ltd.
(Hikvision) reserves all rights to this manual. This manual cannot be reproduced, changed, translated, or distributed, partially or wholly, by any means, without the prior written permission of Hikvision. Trademarks and other Hikvision marks are the property of Hikvision and are registered trademarks or the subject of applications for the same by Hikvision and/or its aliates. Other trademarks mentioned in this manual are the properties of their respective owners. No right of license is given to use such trademarks without express permission. EN50131-1:2006+A1:2009+A2:2017 EN 50131-2-4:2008 Security Grade 2 Environment class II
(c) Lens Holder
(e) Nut
(f) Casing Screw
(j) Sensitivity Settings LOW HIGH AUTO (Default) 4 Installation Method - Bracket Installation 5 Installation Hints 6 The 12 m Lens
(h) Tamper Spring
(i) LED ON/OFF LED ON LED OFF 12m 10m 8m 6m 4m 2m 1m 2.4m 3 Screw Model number PA_3.5 25 4 To use the pet immunity function, please install a pet mask.
(a) Detection Range 85.9 52 zones 4 planes PET Table Sensitivity mode High Auto Weight Low 10 kg 15 kg 5 kg
(c) Microwave Range Control Max: 12 m Medium: 0 to 12 m Min: 0 m
(b) Mounting Height Mounting height range from 1.8 m to 2.4 m. The recommended mounting height is 2.2 m. Note: PET immunity is available up to 12 m and at a height that is below the top plane of view. 1m 2m 4m 6m 8m 10m 12m 1m 2m 4m 6m 8m 10m 12m
(1) Ceiling Bracket Fitting (Non EN compliant)
(2) Wall Bracket Fitting 2 3 3 1 1 2 Note:
Brackets are optional. Brackets sale separately. 7 Resistor Wiring The detector has two method for resistor wiring:
(1) Using headers to select the End of Line resistance (Control panel dependent) on the ALARM/TAMPER header pins.
(2) Select an resistance (Control panel dependent), and add the resistor to ALARM/TAMPER wiring ports of the detector. Note: If EOL (End of Line) wiring is not used, leave the headers OFF. If the headers and the header pins does not match, do not force the header, please select the method 2 to wire the resistor. Method 1 and method 2 should not be used on the ALARM/TAMPER at the same time. TAMPER TAMPER EOL ALARM EOL
ALARM TAMPER TAMPER EOL ALARM EOL
ALARM 1K 2K2 4K7 5K6 1K 2K2 4K7 5K6 TAMPER TAMPER EOL ALARM EOL
ALARM 1K 2K2 4K7 5K6 1K 2K2 4K7 5K6 6K8
(a) Alarm Resistance 1K, 2K2, 4K7, 5K6, 6K8 1K 2K2 4K7 5K6 6K8 1K TAMPER TAMPER EOL ALARM EOL
ALARM
(b) Tamper Resistance 1K 2K2 4K7 5K6 1K, 2K2, 4K7, 5K6 1K 1K 2K2 4K7 5K6 6K8
1K 2K2 4K7 5K6 6K8
103.8 mm 65.7 mm 45.5 mm 99 g
(3.5 oz) NOT READY READY 9 Powering up 10 Dimension and Weight 11 Technical Specification After powering on, the indicator ashes rapidly. Once the detector self test is completed, the LED indicator will go out until the detector detects movement. The connection shows the example:
1. Normal: 1K 2. Alarm: Innite 3. Tamper: 0 K 1K 2K2 4K7 5K6
(1) Normally Closed a. Alarm Control Panel
(2) Single End of Line Wiring
(3) Double End of Line Wiring a. Alarm Control Panel 8 Choose the Connection Type M O C 2 E N O Z M O C 1 E N O Z
a. Alarm Control Panel M O C 2 E N O Z M O C 1 E N O Z
M O C 2 E N O Z M O C 1 E N O Z
The connection shows the example:
1. Normal: 1K 2. Alarm: 2K 3. Tamper: 0 K or innite TAMPER TAMPER EOL ALARM EOL
ALARM TAMPER TAMPER EOL ALARM EOL
ALARM TAMPER TAMPER EOL ALARM EOL
ALARM 1K 2K2 4K7 5K6 6K8 1K 2K2 4K7 5K6 1K 2K2 4K7 5K6 6K8 1K 2K2 4K7 5K6 1K 2K2 4K7 5K6 6K8 b. Detector b. Detector b. Detector 12m, 85.9 Detection range 0.3 to 2 m/s Detection speed High, Auto, Low Sensitivity Yes Auto sensitivity Onboard EOL Yes Digital temperature compensation Yes Technology SEC technology Sealed optics Creep zone protection Direct light lter Tamper protection LED indicators Microwave frequency Microwave range AND/OR mode Pet immunity Power supply Current consumption Operating temperature Storage temperature Operating humidity Installation height Dimension (H W D) Weight Bracket Digital microprocessor based Yes Yes Yes 6500lux Front Green(PIR), Orange(microwave), Blue(alarm) 24Ghz (24.1925Ghz to 24.2125Ghz) Potentiometer adjustment PIR / MW 10Kg (With optional pet mask) 9 to 16 VDC (standard: 12 VDC)
< 15 mA (12 VDC) - Both quiescent and alarm
-10 C ot 55 C (14 F to 131 F)
-20 C ot 60 C (-4 F to 140 F) 10% to 90%
1.8 to 2.4m 103.8 mm 65.7 mm 45.5 mm 99 g Optional wall & ceiling accessory Legal Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, IS PROVIDED AS IS, WITH ALL FAULTS AND ERRORS, AND HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD PARTY. IN NO EVENT WILL HIKVISION, ITS DIRECTORS, OFFICERS, EMPLOYEES, OR AGENTS BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA OR DOCUMENTATION, IN CONNECTION WITH THE USE OF THIS PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE USE OF PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS. HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK ALL RELEVANT LAWS IN YOUR JURISDICTION BEFORE USING THIS PRODUCT IN ORDER TO ENSURE THAT YOUR USE CONFORMS THE APPLICABLE LAW. HIKVISION SHALL NOT BE LIABLE IN THE EVENT THAT THIS PRODUCT IS USED WITH ILLEGITIMATE PURPOSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS. Low is non EN and non INCERT compliant. IC Information CLASS B: CAN ICES-3 (B)/NMB-3(B) Industry Canada ICES-003 Compliance This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploitation est autorise aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformment la rglementation d'Industrie Canada, le prsent metteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou infrieur) approuv pour l'metteur par Industrie Canada. Dans le but de rduire les risques de brouillage radiolectrique l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonne quivalente (p.i.r.e.) ne dpasse pas l'intensit ncessaire l'tablissement d'une communication satisfaisante. This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. Cet quipement doit tre install et utilis une distance minimale de 20 cm entre le radiateur et votre corps. FCC Information Please take attention that changes or modication not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Conditions This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014/30/EU, the LVD Directive 2014/35/EU, the RoHS Directive 2011/65/EU. Class B: This device is intended for mainly home use (Class B) and may be used in all areas B : (B)
. 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info UD17437B Deutsch Espaol Franais Italiano Polski Portugus Svenska