all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 3 |
|
User Manual | Users Manual | 986.28 KiB | November 29 2019 | |||
1 2 3 |
|
Internal photo | Internal Photos | 1.36 MiB | November 29 2019 | |||
1 2 3 |
|
External Photos | External Photos | 401.74 KiB | November 29 2019 | |||
1 2 3 |
|
Label | ID Label/Location Info | 88.39 KiB | November 29 2019 | |||
1 2 3 | Block Diagram | Block Diagram | November 29 2019 | confidential | ||||
1 2 3 | Operation Description | Operational Description | November 29 2019 | confidential | ||||
1 2 3 |
|
Power of Attorney Letter | Cover Letter(s) | 39.36 KiB | November 29 2019 | |||
1 2 3 | RF Exposure Info | November 29 2019 | ||||||
1 2 3 | Schematic | Schematics | November 29 2019 | confidential | ||||
1 2 3 | Schematics | Schematics | November 29 2019 | confidential | ||||
1 2 3 | Test Report | November 29 2019 | ||||||
1 2 3 | Test Setup Photos | November 29 2019 | ||||||
1 2 3 |
|
confidentiality Letter | Cover Letter(s) | 84.74 KiB | November 29 2019 | |||
1 2 3 | Operational description | Operational Description | November 29 2019 | confidential | ||||
1 2 3 | Test Setup Photos | November 29 2019 | ||||||
1 2 3 | RF Exposure Info | November 29 2019 |
1 2 3 | User Manual | Users Manual | 986.28 KiB | November 29 2019 |
DS-K1F600-D6E Series Enrollment Station User Manual DS-K1F600-D6E Series Enrollment Station User Manual Legal Information User Manual 2019 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved. About this Manual The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website ( https://
www.hikvision.com/en/ ). Please use this Manual with the guidance and assistance of professionals trained in supporting the Product. Trademarks and other Hikvision's trademarks and logos are the properties of Hikvision in various jurisdictions. Other trademarks and logos mentioned are the properties of their respective owners. Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED AS IS AND WITH ALL FAULTS AND ERRORS. HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. i DS-K1F600-D6E Series Enrollment Station User Manual YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS. Data Protection During the use of device, personal data will be collected, stored and processed. To protect data, the development of Hikvision devices incorporates privacy by design principles. For example, for device with facial recognition features, biometrics data is stored in your device with encryption method; for fingerprint device, only fingerprint template will be saved, which is impossible to reconstruct a fingerprint image. As data controller, you are advised to collect, store, process and transfer data in accordance with the applicable data protection laws and regulations, including without limitation, conducting security controls to safeguard personal data, such as, implementing reasonable administrative and physical security controls, conduct periodic reviews and assessments of the effectiveness of your security controls. ii DS-K1F600-D6E Series Enrollment Station User Manual Available Model Product Name Model Description Enrollment Station DS-K1F600-D6E DS-K1F600-D6E-F Supports enroll face and card No. Supports enroll face, fingerprint, and card No. iii DS-K1F600-D6E Series Enrollment Station User Manual Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. FCC Conditions This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. EU Conformity Statement This product and - if applicable - the supplied accessories too are marked with "CE"
and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014/30/EU, the RoHS Directive 2011/65/EU 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, iv DS-K1F600-D6E Series Enrollment Station User Manual or dispose of it at designated collection points. For more information see:
www.recyclethis.info 2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury
(Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see:www.recyclethis.info v DS-K1F600-D6E Series Enrollment Station User Manual Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into Dangers and Cautions:
Dangers: Neglecting any of the warnings may cause serious injury or death. Cautions: Neglecting any of the cautions may cause injury or equipment damage. Dangers: Follow these safeguards to prevent serious injury or death. Cautions: Follow these precautions to prevent potential injury or material damage. Danger:
All the electronic operation should be strictly compliance with the electrical safety regulations, fire prevention regulations and other related regulations in your local region. Please use the power adapter, which is provided by normal company. The power consumption cannot be less than the required value. Do not connect several devices to one power adapter as adapter overload may cause over-heat or fire hazard. device. Please make sure that the power has been disconnected before you wire, install or dismantle the When the product is installed on wall or ceiling, the device shall be firmly fixed. If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then please contact the service center. Do not ingest battery, Chemical Burn Hazard. This product contains a coin/button cell battery. If the coin/button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death. Keep new and used batteries away from children. If the battery compartment does not close securely, stop using the product and keep it away from children. If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention. If the product does not work properly, please contact your dealer or the nearest service center. Never attempt to disassemble the device yourself. (We shall not assume any responsibility for problems caused by unauthorized repair or maintenance.) Cautions:
Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment damage). Do not place the device in extremely hot (refer to the specification of the device for the detailed operating temperature), cold, dusty or damp locations, and do not expose it to high electromagnetic radiation. vi DS-K1F600-D6E Series Enrollment Station User Manual The device cover for indoor use shall be kept from rain and moisture. Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is forbidden (ignorance can cause fire danger). Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfunction however), and affecting the endurance of sensor at the same time. Please use the provided glove when open up the device cover, avoid direct contact with the device cover, because the acidic sweat of the fingers may erode the surface coating of the device cover. Please use a soft and dry cloth when clean inside and outside surfaces of the device cover, do not use alkaline detergents. Please keep all wrappers after unpack them for future use. In case of any failure occurred, you need to return the device to the factory with the original wrapper. Transportation without the original wrapper may result in damage on the device and lead to additional costs. Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or equivalent type only. Dispose of used batteries according to the instructions provided by the battery manufacturer. Biometric recognition products are not 100% applicable to anti-spoofing environments. If you require a higher security level, use multiple authentication modes. Please take care of your card and report card loss in time when card is lost. Multiple card types are supported. Please select an appropriate card type according to the card performance and the usage scenarios. vii DS-K1F600-D6E Series Enrollment Station User Manual Contents Chapter 1 Overview .................................................................................................................... 1 Chapter 2 Appearance ................................................................................................................ 2 Chapter 3 Activation ................................................................................................................... 3 3.1 Activate via Device ................................................................................................................. 3 3.2 Activate via SADP ................................................................................................................... 4 Chapter 4 Enroll via Device ......................................................................................................... 5 4.1 Enroll Face via Device ............................................................................................................. 5 4.2 Enroll Fingerprint via Device .................................................................................................. 6 4.3 Enroll Card via Device ............................................................................................................ 7 Chapter 5 Enroll via Client Software ............................................................................................ 8 5.1 Enroll Face via Client Software ............................................................................................... 8 5.2 Enroll Fingerprint via Client Software .................................................................................. 10 5.3 Enroll Card via Client Software ............................................................................................. 13 5.4 Get Person Information from Enrollment Station ................................................................ 16 5.5 Import Person Information in Batch .................................................................................... 16 Chapter 6 Basic Operation ........................................................................................................ 18 6.1 Login .................................................................................................................................... 18 6.1.1 Login by Activation Password ...................................................................................... 18 6.1.2 Login by Administrator ................................................................................................ 19 6.2 Add Administrator ................................................................................................................ 20 6.3 Communication Settings ...................................................................................................... 21 6.4 Manage Enrollment ............................................................................................................. 22 6.5 System Settings .................................................................................................................... 23 6.5.1 Set Time ...................................................................................................................... 23 6.5.2 Set Sound .................................................................................................................... 23 6.5.3 Set Enrollment Rule .................................................................................................... 24 viii DS-K1F600-D6E Series Enrollment Station User Manual 6.5.4 Other Settings ............................................................................................................. 25 6.5.5 Set Biometric Parameters ........................................................................................... 26 6.6 Data Management ............................................................................................................... 27 6.6.1 Import User ................................................................................................................. 27 6.6.2 Export Enrolled Data ................................................................................................... 28 6.6.3 Clear Enrolled Data ..................................................................................................... 29 6.7 System Maintenance ............................................................................................................ 29 Appendix A. Tips When Collecting/Comparing Face Picture ...................................................... 31 Appendix B. Tips for Scanning Fingerprint ................................................................................. 32 ix DS-K1F600-D6E Series Enrollment Station User Manual Chapter 1 Overview Introduction Figure 1-1 Product Appearance The enrollment station can realize multiple user information's enrollment on one device. It supports enrolling face picture, fingerprint, 13.56 MHz IC card No., and 125KHz ID card No. Features 3.97-inch LCD touch screen for face recognition, parameters settings, live view, etc. 2 MP wide-angle dual-lens Face anti-spoofing Face recognition distance: 0.3 m to 1 m Deep learning algorithm Face recognition duration 0.2 s/User; face recognition accuracy rate 99%
2,000 user capacity, 2,000 face capacity, 20,000 card capacity, and 20,000 fingerprint capacity Transmits card and user data from or to the client software via TCP/IP protocol and saves the data on the client software Stand-alone operation Manage, search and set device data after logging in the device locally 1 DS-K1F600-D6E Series Enrollment Station User Manual Chapter 2 Appearance Figure 2-1 Appearance Table 2-1 Appearance Description Description No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 PSAM3 Card Slot (Reserved) PSAM4 Card Slot (Reserved) Screen Camera Supplement Light Camera USB Interface Network Interface Power Interface PSAM Card Slot PSAM Card Slot Debugging Port Fingerprint Module Card Presenting Area 2 DS-K1F600-D6E Series Enrollment Station User Manual Chapter 3 Activation You should activate the device before the first login. After powering on the device, the system will switch to Device Activation page. Activation via the device, SADP tool and the client software are supported. The default values of the device are as follows:
The default IP address: 192.0.0.64 The default port No.: 8000 The default user name (super administrator): admin 3.1 Activate via Device If the device is not activated, you can activate the device after it is powered on. On the Activate Device page, create a password and confirm the password. Tap Activate and the device will activated. Figure 3-1 Activation Page Caution The password strength of the device can be automatically checked. We highly recommend you change the password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product. Proper configuration of all passwords and other security settings is the responsibility of the installer and/or end-user. After activation, if you need to add the device to the client software or other platforms, you should edit the device IP address. For details, see Communication Settings. 3 DS-K1F600-D6E Series Enrollment Station User Manual 3.2 Activate via SADP SADP is a tool to detect, activate and modify the IP address of the device over the LAN. Before You Start Get the SADP software from the supplied disk or the official website http://
www.hikvision.com/en/ , and install the SADP according to the prompts. The device and the PC that runs the SADP tool should be within the same subnet. The following steps show how to activate a device and modify its IP address. For batch activation and IP addresses modification, refer to User Manual of SADP for details. Steps 1. Run the SADP software and search the online devices. 2. Find and select your device in online device list. 3. Input new password (admin password) and confirm the password. Caution STRONG PASSWORD RECOMMENDED-We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product. 4. Click Activate to start activation. Status of the device becomes Active after successful activation. 5. Modify IP address of the device. 1) Select the device. 2) Change the device IP address to the same subnet as your computer by either modifying the IP address manually or checking Enable DHCP. 3) Input the admin password and click Modify to activate your IP address modification. 4 DS-K1F600-D6E Series Enrollment Station User Manual Chapter 4 Enroll via Device 4.1 Enroll Face via Device Before You Start Power on and activate the device. For details about the activation, see Activation . Enable Face Required in Set Enrollment Rule after logging in the device backend. Steps 1. Tap 2. Optional: If you have added an administrator's face in Add Administrator and enabled Verify by on the initial page. Administrator in Set Enrollment Rule , you should verify the administrator's permission.
- Make sure the face is in the face recognition frame when authentication. Figure 4-1 Authenticate Administrator Page Note For details about face recognition, see Tips When Collecting/Comparing Face Picture .
- Tap on the right side and enter the administrator's name and password. 3. Enter the User Enrollment page.
- Create an employee ID and tap Add
- Present a card on the card presenting area. 4. Enroll face. 1) Tap 2) Tap to enter the face enrollment page. and follow the instructions to enroll the face. Note Make sure that face is in the face recognition frame. 3) Optional: Tap 4) Tap to enroll the face again. to complete the face enrollment. 5 DS-K1F600-D6E Series Enrollment Station User Manual Note For details about face recognition, see Tips When Collecting/Comparing Face Picture . 5. Optional: Tap to edit the employee ID. 4.2 Enroll Fingerprint via Device Before You Start Power on and activate the device. For details about the activation, see Activation . Set fingers in Select Finger in Set Enrollment Rule after logging in the device backend. Steps 1. Tap 2. Optional: If you have added an administrator's face in Add Administrator and enabled Verify by on the initial page. Administrator in Set Enrollment Rule , you should verify the administrator's permission.
- Make sure the face is in the face recognition frame when authentication. Figure 4-2 Authenticate Administrator Page Note For details about face recognition, see Tips When Collecting/Comparing Face Picture .
- Tap on the right side and enter the administrator's name and password. 3. Enter the User Enrollment page.
- Create an employee ID and tap Add
- Present a card on the card presenting area. 4. Enroll fingerprint. 1) Tap 2) Select a finger on the Select Finger page. to enter the Select Finger page. Note You can set fingers in Set Enrollment Rule . 3) Follow the instructions and press a finger on the fingerprint module. If the fingerprint is enrolled, the enrolled fingerprint on Select Finger page will turn to blue. 6 DS-K1F600-D6E Series Enrollment Station User Manual 4) Optional: Tap the enrolled fingerprint (in blue) and tap OK in the dialogue box to clear the enrolled data and enroll a new fingerprint. 5. Optional: Tap to edit the employee ID. 4.3 Enroll Card via Device Before You Start Power on and activate the device. For details about the activation, see Activation . Set Card Number per User and Card No. Length in Set Enrollment Rule after logging in the device background. Steps 1. Tap 2. Optional: If you have added an administrator's face in Add Administrator and enabled Verify by on the initial page. Administrator in Set Enrollment Rule , you should verify the administrator's permission.
- Make sure the face is in the face recognition frame when authentication. Figure 4-3 Authenticate Administrator Page Note For details about face recognition, see Tips When Collecting/Comparing Face Picture . on the right side and enter the administrator's name and password.
- Tap 3. Enroll card.
- Present card on the card presenting area and tap OK in the dialogue box. Create an employee ID and tap Next.
- Create an employee ID in the input box, and tap Add to enter the User Enrollment page. Tap and present card on the card presenting area. 4. Optional: Tap to edit the employee ID. 7 DS-K1F600-D6E Series Enrollment Station User Manual Chapter 5 Enroll via Client Software 5.1 Enroll Face via Client Software Before You Start Download and install the client software on your computer before enrollment. Power on and activate the device. For details about the activation, see Activation . Follow the steps below to enroll face. Figure 5-1 Flow Diagram of Enrolling Face Steps 1. Connect the device to the network. 2. Place the device on the desk. 3. Login the client software on the computer. 4. Add an organization. 1) Click Person to enter the Person page. 2) Click Add on the upper left of the page. Figure 5-2 Add Organization 3) Create an organization name. Note Up to 10 levels of organizations can be added. 8 DS-K1F600-D6E Series Enrollment Station User Manual The added organizations will be displayed in the list on the left of the page. 5. Add person. 1) Select an organization from the list on the left. 2) Click Add on right panel. 3) Set the person's basic information, including the person's name, gender, email, tel, effective period, and remark. Figure 5-3 Add Person Note Once the person information is expired, the credentials and access control settings of the person will be invalid and the person will have no authorization to access the doors. 6. Enroll the face. face in the photo. actual needs. 1) On the Add window, click Add Face Remote . 2) Enable Verify by Device to check whether the device managed in the client can recognize the 3) Select the enrollment station from the drop-down list. 4) Click Settings and set the enrollment station's IP address, port No., user name and password. 5) Optional: Enable Face Anti-Spoofing function and set the liveness level according to your 6) Click OK. 7) Face the enrollment station's camera and capture a picture according to the instructions on the enrollment station. to capture again. 8) Click 9) Click OK. 7. Confirm to add the person.
- Click Add to add the person and close the Add Person window. 9 DS-K1F600-D6E Series Enrollment Station User Manual
- Click Add and New to add the person and continue to add other persons. 5.2 Enroll Fingerprint via Client Software Before You Start Download and install the client software on your computer before enrollment. Power on and activate the device. For details about the activation, see Activation . Follow the steps below to enroll fingerprint. Figure 5-4 Flow Diagram of Enrolling Fingerprint Steps 1. Connect the device to the network. 2. Place the device on the desk. 3. Login the client software on the computer. 4. Add an organization. 1) Click Person to enter the Person page. 2) Click Add on the upper left of the page. 10 DS-K1F600-D6E Series Enrollment Station User Manual Figure 5-5 Add Organization 3) Create an organization name. Note Up to 10 levels of organizations can be added. The added organizations will be displayed in the list on the left of the page. 5. Add person. 1) Select an organization from the list on the left. 2) Click Add on right panel. 3) Set the person's basic information, including the person's name, gender, email, tel, effective period, and remark. 11 DS-K1F600-D6E Series Enrollment Station User Manual Figure 5-6 Add Person Note Once the person information is expired, the credentials and access control settings of the person will be invalid and the person will have no authorization to access the doors. 6. On the Credential Fingerprint panel, click +. 7. In the pop-up window, select the collection mode as Remote and select Enrollment Station as the fingerprint recorder from the drop-down list. Figure 5-7 Add Fingerprint Page 12 DS-K1F600-D6E Series Enrollment Station User Manual 8. Set the enrollment station's information. 1) Click Settings and set the enrollment station's IP address, port No., user name and password. 2) Click OK. 9. Enroll the fingerprint. 1) Click Start to start enrollment. 2) Follow the instructions on the enrollment station to enroll the fingerprint. 3) Click Add to save the enrollment. 10. Confirm to add the person.
- Click Add to add the person and close the Add Person window.
- Click Add and New to add the person and continue to add other persons. 5.3 Enroll Card via Client Software Before You Start Download and install the client software on your computer before enrollment. Power on and activate the device. For details about the activation, see Activation . Follow the steps below to enroll face. Figure 5-8 Flow Diagram of Enrolling Card Steps 1. Connect the device to the network. 2. Place the device on the desk. 3. Login the client software on the computer. 4. Add an organization. 1) Click Person to enter the Person page. 2) Click Add on the upper left of the page. 13 DS-K1F600-D6E Series Enrollment Station User Manual Figure 5-9 Add Organization 3) Create an organization name. Note Up to 10 levels of organizations can be added. The added organizations will be displayed in the list on the left of the page. 5. Add person. 1) Select an organization from the list on the left. 2) Click Add on right panel. 3) Set the person's basic information, including the person's name, gender, email, tel, effective period, and remark. 14 DS-K1F600-D6E Series Enrollment Station User Manual Figure 5-10 Add Person Note Once the person information is expired, the credentials and access control settings of the person will be invalid and the person will have no authorization to access the doors. 6. On the Add window, click Credential Card . 7. Add the card No. 1) Click + Settings . 2) Set the mode as Remote and select the card enrollment station from the drop-down list. 3) Set the enrollment station's IP address, port No., user name and password. 4) Set the RF card type. The device can recognize the checked card type. 5) Click OK. 8. Enter the card No.
- Enter the card number manually.
- Place the card on the card enrollment station and click Read to get the card No. The card number will display in the Card No. field automatically. 9. Select the card type according to actual needs. Normal Card The card is used for opening doors for normal usage. Duress Card When the person is under duress, he/she can swipe the duress card to open the door. The door will be unlocked and the client will receive a duress event to notify the security personnel. Patrol Card 15 DS-K1F600-D6E Series Enrollment Station User Manual This card is used for the inspection staff to check the their attendance of inspection. By swiping the card on the specified card reader, the person is marked as on duty of inspection at that time. Dismiss Card By swiping the card on the card reader, it can stop the buzzing of the card reader. 10. Click Add. 11. Confirm to add the person.
- Click Add to add the person and close the Add Person window.
- Click Add and New to add the person and continue to add other persons. 5.4 Get Person Information from Enrollment Station You can get the person information from the device for further operations. Steps Note If the person name stored in the device is empty, the person name will be filled with the issued card No. after importing to the client. The gender of the persons will be Male by default. If the card number or person ID (employee ID) stored on the device already exists in the client database, the person with this card number or person ID will not be imported to the client. 1. Enter Person module. 2. Select an organization to import the persons. 3. Click Get from Device. 4. Select Enrollment Station from the drop-down list. 5. Configure the enrollment station's information. 1) Click Settings. 2) Set the enrollment station's IP address, port, user name of the device administrator, and password. 3) Click OK. 6. Click Get to start importing the person information to the client. The person information, including person details, person's fingerprint information (if configured), and the linked cards (if configured), will be imported to the selected organization. 5.5 Import Person Information in Batch You can import the persons information in batch. Steps 1. Enter the Person module. 16 DS-K1F600-D6E Series Enrollment Station User Manual 2. Select an organization to import the person. 3. Click Get from Device. 4. Select Enrollment Station from the drop-down list. 5. Configure the enrollment station's information. 1) Click Settings. 2) Set the enrollment station's IP address, port, user name of the device administrator, and password. 3) Click OK. 6. Click Export Template and you can export the template to the PC. 7. Edit person's information and save. 8. Click Import and the edited data will be imported to the client software. 17 DS-K1F600-D6E Series Enrollment Station User Manual Chapter 6 Basic Operation 6.1 Login Login the device backend to set the device basic parameters. You should enter the device activation password for the first login. Or if you have add an administrator's face picture, you can login via the added face picture. 6.1.1 Login by Activation Password Login the device backend to set the device basic parameters. You should enter the device activation password for the first login. Steps 1. Long tap on the initial page for 3 s to enter the administrator authentication page. Figure 6-1 Authenticate Administrator Page to enter the password entering page. 2. Tap 3. Enter the administrator's name and password. 4. Tap OK to enter the home page. Figure 6-2 Home Page 18 DS-K1F600-D6E Series Enrollment Station User Manual Note The device will be locked for 30 minutes after 5 failed password attempts. 5. Optional: Tap to exit the page and be back to the initial page. 6.1.2 Login by Administrator Login the device backend to set the device basic parameters. If you have add an administrator's face picture, you can login via the added face picture. Before You Start Add an administrator and add a face picture for the administrator. For details, see Add Administrator . Steps 1. Long tap on the initial page for 3 s to enter the administrator authentication page. 2. Authenticate the administrator's face to enter the home page. Figure 6-3 Authenticate Administrator Page Figure 6-4 Home Page Note The device will be locked for 30 minutes after 5 failed fingerprint or card attempts. 19 DS-K1F600-D6E Series Enrollment Station User Manual 3. Optional: Tap 4. Optional: Tap and you can enter the added admin user name and password to login. and you can exit the page and be back to the initial page. 6.2 Add Administrator The administrator can login the device backend and configure the device parameters. Steps 1. Long tap on the initial page for 3 s and login the device home page. 2. Tap Admin to enter the Administrator page. Figure 6-5 Administrator Page 3. Set the administrator's parameters.
- Edit the super administrator's parameters: Tap admin and edit the super administrator's face and password.
- Add a new administrator: Tap and set the administrator's type, add face and password. Figure 6-6 Administrator Information Page Super Administrator Contains all management and operation permissions. Normal Administrator Supports enrollment management and communication management. During remote configuration, the normal administrator can only gain parameters. 20 DS-K1F600-D6E Series Enrollment Station User Manual 4. Tap to save the settings. Note By default, the system contains a super administrator. You cannot edit its No., name, and type. and you cannot delete it. The administrator's No. and name cannot be edited. Up to 5 administrators can be added. The face and password of the super administrator, normal administrator, and normal user cannot be the same. 6.3 Communication Settings Set the device wired network and wireless network. Set Wired Network Parameters Make sure the device has connected the Ethernet. Long tap on the initial page for 3 s and login the home page. Tap Comm. Wired Network . Figure 6-7 Set Wired Network Set the device IP address, subnet mask, and gateway. Set Wireless Network Parameters The device can connect to the Ethernet via wireless connection. Long tap on the initial page for 3 s and login the home page. Tap Comm. Wi-Fi . Figure 6-8 Wi-Fi Page 21 DS-K1F600-D6E Series Enrollment Station User Manual After enabling WLAN, you should select a Wi-Fi for connection. Enter the Wi-Fi's password, IP address, subnetmask, and gateway. Tap to save the settings. Or enable DHCP and enter the Wi-Fi's password to connect. Tap to save the settings. 6.4 Manage Enrollment You can view the enrolled person information and delete the enrolled data. Steps 1. Long tap on the initial page for 3 s and login the home page. Tap Enrollment. Figure 6-9 Enrollment Management Page 2. You can view all enrolled person's information on this page. 3. You can also perform the following operations. Incomplete View Details Face/
Fingerprint/
Card Tap Incomplete and the system will list the persons which have not enrolled all data. Tap a person in the list to view details. Tap enrolled data. Tap a person in the list to enter the User Information page. You can delete the enrolled data according to actual requirements. to delete the person and all Note Only parts of the device models support fingerprint recognition function. Refer to the actual page for details. Search Enter a person's employee ID and tap the search icon, or present a card on the card presenting area. The system will enter the User Information page. 22 DS-K1F600-D6E Series Enrollment Station User Manual 6.5 System Settings 6.5.1 Set Time You can set the device time format and the current time. Long tap on the initial page for 3 s and login the device home page. Tap System Time . You can set the device time format and the current time. Figure 6-10 Time Settings Page 6.5.2 Set Sound Enable or disable the Keypad Sound and Voice Volume. You can also adjust the Voice Volume. Long tap on the initial page for 3 s and login the device home page. Tap System Sound . You can enable or disable the device keypad sound and voice volume. Voice volume is also adjustable. Figure 6-11 Sound Settings 23 DS-K1F600-D6E Series Enrollment Station User Manual Note The available volume range is from 0 to 10. The larger the value, the louder the volume. 0 represents disable the voice prompt function. 6.5.3 Set Enrollment Rule Set the enrollment rules before data enrollment. Long tap on the initial page for 3 s and login the home page. Tap System Enrollment Rules . Figure 6-12 Enrollment Rules Page The configurable rules and descriptions are as follows:
Verify by Administrator If enabling the function, you should verify the administrator's permission before enrollment. Employee ID Length Set the employee ID's length when enrolling a person's information. Employee ID Required You must enroll the employee ID when enrolling a person's information. Name Required You must enroll the person's name when enrolling a person's information. Name Length Set the name's length when enrolling a person's information. Verify Name 24 DS-K1F600-D6E Series Enrollment Station User Manual When enter a name in the enroll user page, the system will compare the name with all names in the database to avoid name duplication. Face Required You must enroll the person's face when enrolling a person's information. Select Finger Set the enrolling fingers when enrolling a person's fingerprint. Card Number per User Set the maximum card number that a person can enroll. Card No. Length Set the card No.'s length when enrolling a person's information. 6.5.4 Other Settings You can set the device white light brightness, IR light brightness, and video standard. Long tap on the initial page for 3 s and login the device home page. Tap System. Figure 6-13 System Settings Page White Light Brightness Set the supplement white light's brightness. The brightness range is from 1 to 100. 0 refers to turning off the light. 1 refers to the darkest, and 100 refers to the brightest. IR Light Brightness Set the IR light brightness when the IR light is enabled. The brightness range is from 1 to 100. 0 refers to turning off the light. 1 refers to the darkest, and 100 refers to the brightest. Video Standard Set the video frame rate when performing live view remotely. After changing the standard, you should reboot the device to take effect. PAL 25 DS-K1F600-D6E Series Enrollment Station User Manual 25 frames per second. Suitable for mainland China, Hong Kong (China), the Middle East countries, Europe countries, etc. NTSC 30 frames per second. Suitable for the USA, Canada, Japan, Taiwan (China), Korea, the Philippines, etc. 6.5.5 Set Biometric Parameters You can customize the face parameters to improve the face recognition performance. The configurable parameters includes face anti-spoofing, liveness security level, pitch angle, yaw angle, and pupillary distance. Long tap on the initial page for 3 s and login the home page. Tap Biometric. Parameter Face Anti-Spoofing Figure 6-14 Biometric Parameters Page Table 6-1 Face Picture Parameters Description Enable or disable the face anti-spoofing function. If enabling the function, the device can recognize whether the person is a live one or not. Note Biometric recognition products are not 100% applicable to anti-spoofing environments. If you require a higher security level, use multiple authentication modes. Liveness Security Level After enabling face anti-spoofing function, you can set the matching Pitch Angle security level when performing live face authentication. The maximum pitch angle when starting face authentication. By default, the angle is 30. 26 DS-K1F600-D6E Series Enrollment Station User Manual Parameter Yaw Angle Pupillary Distance Description The maximum yaw angle when starting face authentication. By default, the angle is 45. The minimum resolution between two pupils when starting face recognition. The actual resolution should be larger than the configured value. By default, the resolution is 40. 6.6 Data Management You can import user list, export user list template, export enrolled data, and clear enrolled data. 6.6.1 Import User Import the user information from the USB flash drive to the device. Before You Start Plug the USB flash drive in the USB interface on the device. Steps 1. Long tap on the initial page for 3 s and login the home page. 2. Tap Data. Figure 6-15 Data Management Page 3. Tap Export Template. The template will be exported to the USB flash drive. 4. Edit the exported table and enroll the user information. Note Make sure the edited file is saved in the root directory of the USB flash drive. Requirements of face picture: It should be taken in full-face view, directly facing the camera. Do not wear a hat or head covering when taking the face picture. The format should be JPEG 27 DS-K1F600-D6E Series Enrollment Station User Manual or JPG. The resolution should be more than 640 480 pixel. The picture size should be between 60 KB and 200 KB. 5. Tap Import User. Note Up to 20,000 users can be imported. Result The system will read the user information in the USB flash drive automatically and import the data to the device. 6.6.2 Export Enrolled Data Export enrolled data from the device to the USB flash drive. Before You Start Plug the USB flash drive in the USB interface on the device. Note The supported USB flash drive format is FAT32. The system supports the USB flash drive with the storage of 1G to 32G. Make sure the free space of the USB flash drive is more than 512M. The exported user data is a DB file, which cannot be edited. Steps 1. Long tap on the initial page for 3 s and login the home page. 2. Tap Data. Figure 6-16 Data Management Page 3. Tap Export Enrolled Data. All enrolled data will be exported to the USB flash drive. 28 DS-K1F600-D6E Series Enrollment Station User Manual 6.6.3 Clear Enrolled Data Delete all enrolled data in the device, including all face pictures, fingerprints, card, etc. Long tap on the initial page for 3 s and login the home page. Tap Data. Figure 6-17 Data Management Page Tap Clear Enrolled Data to delete all enrolled data in the device, including all face pictures, fingerprints, card, etc. 6.7 System Maintenance You can view the device system information and capacity. You can also restore the system to factory settings, default settings, and reboot the system. Long tap on the initial page for 3 s and login the home page. Tap Maint.. Figure 6-18 Maintenance Page System Information You can view the device information. Note The page may vary according to different device models. Refers to the actual page for details. 29 DS-K1F600-D6E Series Enrollment Station User Manual Capacity You can view the number of administrator, user, face picture, card, and event. Note Parts of the device models support displaying the fingerprint number. Refers to the actual page for details. Restore to Default All parameters, except for the communication settings, remotely imported user information, will be restored to the default settings. The system will reboot to take effect. Restore to Factory All parameters will be restored to the factory settings. The system will reboot to take effect. Upgrade Plug the USB flash drive in the device USB interface. Tap Upgrade OK , and the device will read the digicap.dav file in the USB flash drive to start upgrading. Reboot The device will reboot after the confirmation. 30 DS-K1F600-D6E Series Enrollment Station User Manual Appendix A. Tips When Collecting/Comparing Face Picture The position when collecting or comparing face picture is as below:
Expression Keep your expression naturally when collecting or comparing face pictures, just like the expression in the picture below. Do not wear hat, sunglasses, or other accessories that can affect the facial recognition function. Do not make your hair cover your eyes, ears, etc. and heavy makeup is not allowed. Posture In order to get a good quality and accurate face picture, position your face looking at the camera when collecting or comparing face pictures. Size Make sure your face is in the middle of the collecting window. 31 DS-K1F600-D6E Series Enrollment Station User Manual Appendix B. Tips for Scanning Fingerprint Recommended Finger Forefinger, middle finger or the third finger. Correct Scanning The figure displayed below is the correct way to scan your finger:
You should press your finger on the scanner horizontally. The center of your scanned finger should align with the scanner center. Incorrect Scanning The figures of scanning fingerprint displayed below are incorrect:
Environment The scanner should avoid direct sun light, high temperature, humid conditions and rain. When it is dry, the scanner may not recognize your fingerprint successfully. You can blow your finger and scan again. 32 DS-K1F600-D6E Series Enrollment Station User Manual Others If your fingerprint is shallow, or it is hard to scan your fingerprint, we recommend you to use other authentication methods. If you have injuries on the scanned finger, the scanner may not recognize. You can change another finger and try again. 33 UD16571B
1 2 3 | Internal photo | Internal Photos | 1.36 MiB | November 29 2019 |
SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 1 of 10 Internal Photos Applicant:
Hangzhou Hikvision Digital Technology Co., Ltd. Address of Applicant:
No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China Equipment Under Test (EUT):
Product Name:
Enrollment Station Model No.:
DS-K1F600-D6E-F Page 1 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 2 of 10 Page 2 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 3 of 10 Page 3 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 4 of 10 Page 4 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 5 of 10 Page 5 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 6 of 10 Page 6 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 7 of 10 Page 7 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 8 of 10 Page 8 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 9 of 10 Page 9 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 10 of 10 End Page 10 of 10
1 2 3 | External Photos | External Photos | 401.74 KiB | November 29 2019 |
SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 1 of 5 External Photos Applicant:
Hangzhou Hikvision Digital Technology Co., Ltd. Address of Applicant:
No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China Equipment Under Test (EUT):
Product Name:
Enrollment Station Model No.:
DS-K1F600-D6E-F Page 1 of 5 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 2 of 5 Page 2 of 5 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 3 of 5 Page 3 of 5 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 4 of 5 Page 4 of 5 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 5 of 5 End Page 5 of 5
1 2 3 | Label | ID Label/Location Info | 88.39 KiB | November 29 2019 |
FIIK VISION Enrollment Station Model: DS-K1F600-D6E-F VP: 12V==-1.5A SN: CC12345678 09/2019 imiliivinil) = CE Made in China FCC ID:2ADTD-K1F600D6EF This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1)this device may not cause harmful interference, and
(2)this device must accept any interference received, a7 including interference that may cause undesired operation. Manufacturer: Hangzhou Hikvision Digital Technology Co.,Ltd. Address: No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China Label location
1 2 3 | Power of Attorney Letter | Cover Letter(s) | 39.36 KiB | November 29 2019 |
Hangzhou Hikvision Digital Technology Co., Ltd. TO:
Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Date: 2019-10-18 Regarding: FCC ID: 2ADTD-K1F600D6EF To whom it may concern:
We, the undersigned, hereby authorize Parlam Zhan to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with Hangzhou Hikvision Digital Technology Co., Ltd. This authorization is valid until further written notice from the applicant. Name (Printed): Xiuying Zhang Title: Senior Certification engineer Signature:
On behalf of Company: Hangzhou Hikvision Digital Technology Co., Ltd. Telephone: +86-0571-88075998-62460
1 2 3 | confidentiality Letter | Cover Letter(s) | 84.74 KiB | November 29 2019 |
No. 555 Qianmo Road, Binjiang District, angzhou 310052, China Confidentiality Request regarding application for FCC ID: 2ADTD-K1F600D6EF SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States Hangzhou Hikvision Digital Technology Co., Ltd. To:
From: Hangzhou Hikvision Digital Technology Co., Ltd. Regarding:
LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commissions rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. Sincerely, Signature:
Printed Name (on file with the FCC associated with the Grantee Code): Xiuying Zhang Title: Senior Certification engineer Company Name: Hangzhou Hikvision Digital Technology Co., Ltd.
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-11-29 | 2422 ~ 2452 | DTS - Digital Transmission System | Original Equipment |
2 | 13.56 ~ 13.56 | DXX - Part 15 Low Power Communication Device Transmitter | ||
3 | 0.125 ~ 0.125 | DCD - Part 15 Low Power Transmitter Below 1705 kHz |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 3 | Effective |
2019-11-29
|
||||
1 2 3 | Applicant's complete, legal business name |
Hangzhou Hikvision Digital Technology Co., Ltd.
|
||||
1 2 3 | FCC Registration Number (FRN) |
0024149825
|
||||
1 2 3 | Physical Address |
No. 555 Qianmo Road, Binjiang District
|
||||
1 2 3 |
Hangzhou
|
|||||
1 2 3 |
Hangzhou, N/A
|
|||||
1 2 3 |
China
|
|||||
app s | TCB Information | |||||
1 2 3 | TCB Application Email Address |
U******@SGS.COM
|
||||
1 2 3 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
1 2 3 |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
|||||
app s | FCC ID | |||||
1 2 3 | Grantee Code |
2ADTD
|
||||
1 2 3 | Equipment Product Code |
K1F600D6EF
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 3 | Name |
X**** Z****
|
||||
1 2 3 | Telephone Number |
+86-5********
|
||||
1 2 3 | Fax Number |
+86-5********
|
||||
1 2 3 |
z******@hikvision.com
|
|||||
app s | Technical Contact | |||||
1 2 3 | Firm Name |
SGS-CSTC Standards Technical Services Co., Ltd.
|
||||
1 2 3 | Name |
P******** Z******
|
||||
1 2 3 | Physical Address |
588 West Jindu Road, Xinqiao, Songjiang
|
||||
1 2 3 |
ShangHai, 201612
|
|||||
1 2 3 |
China
|
|||||
1 2 3 | Telephone Number |
86 21********
|
||||
1 2 3 | Fax Number |
86 21********
|
||||
1 2 3 |
P******@sgs.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 3 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 3 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 3 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 3 | Equipment Class | DTS - Digital Transmission System | ||||
1 2 3 | DXX - Part 15 Low Power Communication Device Transmitter | |||||
1 2 3 | DCD - Part 15 Low Power Transmitter Below 1705 kHz | |||||
1 2 3 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Enrollment Station | ||||
1 2 3 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 3 | Modular Equipment Type | Does not apply | ||||
1 2 3 | Purpose / Application is for | Original Equipment | ||||
1 2 3 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 3 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 3 | Grant Comments | Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter evaluation procedures as documented in this filing. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has a 20 MHz, 40 MHz bandwidth mode. | ||||
1 2 3 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 3 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 3 | Firm Name |
SGS-CSTC Standards Technical Services Co.,Ltd.
|
||||
1 2 3 | Name |
L**** Y********
|
||||
1 2 3 | Telephone Number |
+86 (********
|
||||
1 2 3 |
l******@sgs.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | CC | 2412 | 2462 | 0.036 | |||||||||||||||||||||||||||||||||||
1 | 2 | 15C | CC | 2422 | 2452 | 0.017 | |||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15C | CC | 13.56000000 | 13.56000000 | ||||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
3 | 1 | 15C | CC | 0.12500000 | 0.12500000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC