1 2 3 Hybrid Security Control Panel E N G L I S H Diagram References Appearance 1 Indicators 1 22 AC Power Fault 23 4 5 Link Arm/Disarm Alarm Power O No Fault Power On System Fault Panel is added to Hik-connect account Panel is not added to Hik-connect account Armed Disarmed Alarm Occurred No Alarm Device Tampered Components 26 Lock Nut 27 28 29 Power Interface Wiring Terminal Network Interface 210 211 212 213 Reset Button Battery Connector TAMPER Switch AP&STA Switch Note: Remove the rear cover, and some of the components and interfaces are on the rear panel. Wiring and Installation 2 1. Loosen the screw on the top, press the lock nut, and open the case of the control panel. 2. Route the cables, and secure the rear cover in the installation position with the supplied screws. 3. Fix the SIM card module (should be purchased separately) with four plastic bolts. 4. Fix the telephone module (should be purchased separately) with two plastic bolts. 5. Wire the cables . 1 2 3 4 Telephone Module Wiring Alarm Input/Alarm Output/RS-485 Wiring 21 Alarm Input Wiring a. NC Detector NO Detector b. Unoccupied Zone c. d. Tamper-proof Alarm Output Wiring 22 23 RS-485 Wiring: Wireless Receiver, keypad, etc. Network Power Supply 6. Connect the battery to the control panel. Note: The condition of no SIM card, no battery, AC power o, or network disconnected, will cause Control Panel Fault. 7. Fix the power cables with the cable clip. 8. Close the control panel, and tighten the top screws to complete the installation. TAMPER Screw It is compulsory to secure the TAMPER screw. Set Up 3 Set up via Web Client Log Into the Web Client Default IP Address when using mobile broswer in the AP mode:192.168.8.1. The device must be in the AP mode. Default IP Address when connecting the network cable with computer directly :192.0.0.64 Input the device IP address in the address bar of the web browser. Create a password to activate the device and log into the web client. Add a Camera for the Zone The function varies depends on the model of device. 1. Click System-Network Camera, and you can add cameras for the control panel. 2. Enter the Device Management page, select a zone, and select a camera to link with the zone. You can also link a camera with the zone via APP, refer to the Security Control Panel User Manual for details. Congure Video-Push You can view the alarm video via APP and email. For detailed settings, refer to Security Control Panel User Manual. Set up via APP 1. Log into the App Store or Google Play and input Hik-Connect to search and install the mobile client. 2. Log into the APP with Hik-Connect account. 3. Tap Add Device. Scan the device QR code on the rear panel(on the lable). 4. Tap Connect to a Network. Select Wireless Connection (AP) as the connection mode. 5. Push the AP/STA mode switch to the AP position, tab Conrm. 6. Tap Connect to Wi-Fi on the promt-up window. Select and connect to a stable Wi-Fi , and click Next. 7. Create a password to activate the device. 8. Push the AP/STA mode switch to the STA position. Note: You need to enter the Verication Code (on the device lable which is pasted on the rear panel) before activation if you add the device by entering the device serial No.(SN). Set up via 4200 Client 1. Download and install the iVMS-4200 client. Note: Get the client software from the ocial website:www.hikvision.com. 2. Enter Device Management page, select the device in the Online Device List, click Edit Network Settings, change the port as 80, and click Add to Client. Note: You should activate the device for the rst usage. Restore Default Settings Reboot the device. Boot the device, and hold the reset button for 5s after the Fault indictaor ashes 3 times. The device will prompt a message to indicates the operation status. Specification Model DS-PHA64-W4P Hybrid Security Control Panel with Plastic Case Device connection Alarm input Alarm output Wireless Detector Wireless Output expander Siren Keyfob Partition Zone Alarm output Scheduled arming/disarming SMS notification
(with 3G/4G/GPRS module) Network camera accessing Application &
Protocol Application Protocol Network Wi-Fi Interface &
Component User Others Wired network Cellular Network
(with 3G/4G/GPRS module) Standard Encryption Configuration Distance TAMPER Switch Network Interface Telephone Interface RS-485 Terminal Siren Power Interface Battery Interface User Tag Operation Temperature Operation Humidity Dimension (W H D) Up to 56 Up to 8 1 wired siren (on-board connection) 2 wireless sirens 8, valid operation interval: 3 s 8 8 on-board zones, and 56 wired/wireless zones expadable 4 on-board outputs, and 60 wired/wireless outputs expadable Supported Supports up to 8 mobile phone numbers 4 iVMS-4200 (client software) Hik-Connect (mobile client) ISAPI: Supports client software and web client Cloud P2P: Supports cloud P2P privacy protocol DC09: ARC accessible (CID/SIA) 10M/100M Ethernet Supports report push- notification to ARC & Cloud 802.11b/g/n 64/128-bit WEP,WPA/
WPA2,WPA-PSK/WPA2-
PSK,WPS AP Mode Indoor: 50 m Outdoor: 100 m 1, front cover tamper-proof 1, RJ45 10M/100M Ethernet Interface 1, PSTN expander interface 1, extended up to 64 inputs/outputs (with RS-485 module), and 9 wired keypads extendable 1, 12V Lithium battery (-P model) Installer: 1 Administrator: 1 Manufactuer:1 Operator: 45 12 10 C to 55 C (-4 F to +122 F) 10% to 90% (No condensing) Plastic Case: 220 mm (8.6") 152 mm (6.0") 31.5 mm(1.2") 2 21 22 23 24 21 22 23 24 25 26 27 28 29 210 211 212 213 STA AP STA AP 1 Telephone Line Cut Off Indicator 4 2 3 Power Indicator 4 L CON101 N e n o h p e e T l e n L i e n o h p e e T l e n L i e n o h p e e T l e n o h p e e T l Telephone Module Caustic Line GND NULL Line 220V~
CAUTION CABLES CAN ONLY BE ROUTED THROUGH THE REAR PANEL. DO NOT ROUTE THE ANTENNA WIRE THROUGH THE ELECTRICAL BOARD 12VDC Power Adapter Keypad Siren 220V~
Alarm Lamp Alarm Lamp Alarm Lamp Alarm Lamp 2K2 EOL 2K2 EOL 2K2 EOL 2K2 EOL 2K2 EOL 2K2 EOL 2K2 EOL 2K2 EOL N.O N.O N.O N.O N.O N.O N.O N.O N.C N.C N.C N.C N.C N.C N.C N.C N CON101 L 12V G 485+
485 12V_BELL G 12V_AUX G NO/NC1 COM1 NO/NC2 COM2 NO/NC3 COM3 NO/NC4 COM4 Z1 G Z2 Z3 G Z4 Z5 G Z6 Z7 G Z8 AUX-
AUX+
D- D+
23 OR AUX-
AUX+
D- D+
22 C1 PGM1 21 2a 2b Security Control Panel Peripheral Security Detector Security Control Panel Peripheral Security Detector Z C 2.2K NC C Z C 2.2K NO C Dry Contact 2c Security Control Panel Z C 2d 2.2K TAMPER K 2
. 2 C N O N D E T E C T OR Z C Set up via APP 28 25 STA AP STA AP STA AP STA AP CAUTION SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY 25 1 2 3
...... 26 27 CAUTION COPER OR COPER WIRE CANNOT BE EXPOSED AT THE ELECTRICAL TERMINAL CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS 28 CAUTION A TWO-POLE DISCONNECTED DEVICE (BREAKER) SHALL BE PROVIDED WHEN INSTALLED Product Information COPYRIGHT 2019 Hangzhou Hikvision Digital Technology Co., Ltd. ALL RIGHTS RESERVED. Any and all information, including, among others, wordings, pictures, graphs are the properties of Hangzhou Hikvision Digital Technology Co., Ltd. or its subsidiaries (hereinafter referred to be Hikvision). This user manual (hereinafter referred to be the Manual) cannot be reproduced, changed, translated, or distributed, partially or wholly, by any means, without the prior written permission of Hikvision. Unless otherwise stipulated, Hikvision does not make any warranties, guarantees or representations, express or implied, regarding to the Manual. About this Manual This Manual is applicable to the Axiom Security Control Panel Kit. The Manual includes instructions for using and managing the product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to rmware updates or other reasons. Please nd the latest version in the company website (http://overseas.hikvision.com/en/). Please use this user manual under the guidance of professionals. Trademarks Acknowledgement and other Hikvisions trademarks and logos are the properties of Hikvision in various jurisdictions. Other trademarks and logos mentioned below are the properties of their respective owners. This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the RE Directive 2014/53/EU, the EMC Directive 2014/30/EU, the LVD Directive 2014/35/EU, the RoHS Directive 2011/65/EU 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info 2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specic battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see:www.recyclethis.info FCC Information Please take attention that changes or modication not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. FCC Conditions This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation UD15863B-A Note:
The 868 Mhz wireless siren can be enrolled to the hybrid control panel via the wireless receiver that is at the address of 9. The products do not contain the PSTN, 2G, 3G, or 4G function, but support the extension module for PSTN, 2G, 3G and 4G. The AP mode is only Supported by device with Wi-Fi function.