NO4 COM4 NC4 NO3 COM3 NC3 NO2 COM2 NC2 NO1 COM1 NC1 b c d NC NO a C N M O C O N C N M O C O N e 2 2 3 60.8 mm m m 5
. 8 2 2 206.5 mm 1 b 1 2 5 2 3 DS-PRP100 Security Radar E N G L I S H Diagram References 1 Indicator a. Power Supply Indicator Solid Green: Detector Power on b. Fault Alarm Indicator Flashing Red: Fault Alarm Occurred Solid Green: Alarm Restored c. Zone Alarm Indicator Solid Red: Zone Alarm Occurred Solid Green: Alarm Restored d. Formatting Indicator Red and Green LED Flashes 3 Times: Formatting Successfully 4 Installation Before You Start:
1 UD16651B a b c d Formatting 2 Loosen the screws on the rear cover to remove the cover. Hold the Reset button while powering the radar on until the red and green LED ashes 3 times. Wiring 3 a. Alarm Output Wiring (4-Ch Weak Current Output) b. Alarm Input Wiring (Reserved) c. DC Power Supply Wiring d. Ethernet (PoE Port) Wiring e. Grounding The recommended installation height is 2.5 m. Make sure that the mounting surface is strong enough to withstand at least 50 N, as well as four times the weight of the device and the bracket. Ceiling Mounting 1. Attach the mounting bracket on the detector with four supplied screws. 2. Loosen the screws on both side of the bracket. 3. Adjust the angle of the detector. 4. Tighten the screws on both sides of the bracket to complete the installation. Pole Mounting 1. Attach the mounting bracket on the detector with four supplied screws. 2. Loosen the screws on both sides of the bracket. 3. Adjust the angle of the detector. 4. Tighten the screws on both sides of the bracket to complete the installation. Test Test the radar after installation to make sure it is properly mounted. Power on the radar and make sure there is no large object in the monitoring area. Make the detector access into the Internet. The radar and the PC that runs the software should be in the same IP segment. 1. Download and install the iVMS-4200 client software. 2. Enter Device Management page, and click Online Device. Note: You should activate the device for the rst usage. Select the device in the Online Device List, click Activate, create a password to activate the device. Scan the QR code to get the User Manual of Security Radar. 3. Select the radar in the Online Device List. Click Add, set the port as 80, and check Import to Group. If the IP segment of the radar is not the same as the PCs, click Add in the Device for Management list and enter the radar IP address in the pop-up window to add the radar. You need to set the port as 80 and check Import to Group. 4. Upload Map: In iVMS-4200 client software, enter E-map, select a radar and click Add map to select a map. 5. Click Edit Scale, draw a path on the map and set the plotting scale. 6. Expand the device group in the list on the left, and drag the radar onto the map. 7. Move along the edge of the required monitoring led. Make sure the target sign (red arrow) is moving within the radar area (gray sector) shown on the added map. If the target sign is not within the sector, you need to adjust the mounting position or angle of the radar. 4 6 1 Set Up Add Zone or Trigger Line for the Detector 1. In iVMS-4200 client software, enter E-map. 2. Click Edit - RadarEdit - AddZone or AddAlarmLine, and click to draw a zone or an alarm line on the radar detection area. 3. Right-click to nish drawing. 4. Set the parameters of the zone or alarm line in the pop-up window. Zone: edit the zone parameters in the pop-up window. Click OK to nish the settings. Alarm Line: set the rule of the line (left->right, left<-right, left<->right). Click OK to nish the settings. Note: The alarm line is not allowed to be crossed. Link the camera to the Zone Before the operation, you need to click RadarArm - AllRadarDisarm on the E-map page or click the selected radar and click disarm to disarm the radar. 1. In iVMS-4200 client software, select the radar on Device Management page and click to enter the conguration page. You can also enter the device IP address in the web browser to enter the conguration page. 2. Click Smart Rule Settings - Camera Linkage Settings. 3. Click + to add cameras to the radar. 4. Select a camera in the Camera IP Address list, and select the radar zone or the alarm line (or whole eld) in the Zone Linkage list or the Alarm Line list. 5. Add the camera to iVMS-4200 client software: In the client software, enter Device Management page, click Add in the Device for Management list, and enter the IP address, user name and password of the camera in the pop-up window. Initial Position settings Calibrate the Speed Dome Before the operation, you need to disable the parking function, and set the initial position of the speed dome. You also need to disarm the radar. a Before calibration, set the initial position of the speed dome to ensure the tracking accuracy. 1. Select a reference object about 50 m away from the speed dome. On the reference object, select a point whose altitude is the same as the speed domes. 2. Enter the IP address of the speed dome in the web browser to enter the web client. Adjust the PTZ buttons on the Live View page to make the reference object displayed in the image, and click to zoom in the reference object. 3. Click , and click the reference point to middle the point in the frame. 4. Enter Conguration - PTZ - Initial Position, and click Set to set the initial position. 3D
Calibration b If the speed dome is installed together with the radar, select the calibration mode as Single Calibration. Otherwise, set the calibration as Multiple Calibration. For single calibration, you can refer to the following steps, and see user manual for multiple calibration. 1. In iVMS-4200 client software, enter Device Management page, click Group. Click Encoding Channels in the group of the radar. Click Import and check cameras to link with the radar. 2. In iVMS-4200 client software, enter E-map page, click Edit - RadarEdit - MasterSlaveEdit. 3. Click the live view window, select the linked camera needs to be calibrated, and double click the live view window to maximum it. 4. Select Single Calibration as the calibration mode. 5. Ask the calibration sta to move in the radar detection eld. Click the track of the calibrate sta, and the color of the selected track will change from red to white. 6. Click Add Cal to add a calibration point. 7. Ask the calibration sta to stand at the calibration point within 20 to 40 m directly in front of the radar. Note: The track disappears if the calibration sta is standing in the place for more than 7 s. If the calibration sta does not move to the calibration point when the track disappears, you need to ask the calibration sta to move again, and click the track of the calibration sta to continue the calibration. 8. Click the added calibration point in the Info list to update the radar position of the calibration sta. 9. Adjust the PTZ buttons on the right of the live view window to update the PTZ position: Click +/- to scale the calibration sta to a t size (The altitude of the calibration sta is about 2/3 of the altitude of the window), and adjust the PTZ to make the object align with the sign + at the center of the frame. 10. Select the live view window of the speed dome, and Check Enable Tracking. 11. Click Sure. For detailed settings, scan the QR code to get the User Manual of Security Radar. DS-PRP100 100 m 10 1.2 m Specication Model Detection range Horizontal angle Distance measurement accuracy Max. target number 5 Velocity range Alarm line Zone Relay output Network interface Communication protocol 9 to -9 m/s 4 8 4-ch weak current output:
DC 5 VC, 0.5 A/125 AVC, 300 mW 1 RJ45 10 M/100 M self-adaptive, supports POE Standard ISAPI protocol, NAL2300 protocol, HTTP, DNS, NTP, TCP, UDP, DHCP, ARP and SSH Exception detection Power Operation temperature Operation humidity Dimension (W H D) IP level Weight Tampering alarm Moving alarm DC 12 V 40 C to 65 C 10% to 90%
DC 12 V IP67 1.73 kg Installation Bracket installation Installation height: 1.2m to 4m Recommended height: 2.5m 6 a 4 50 m H H=h h Edit Map Edit Scale RadarEdit MasterSlaveEdit 2 Edit Map Edit Scale RadarEdit 100 90 80 70 60 50 40 30 20 10 Radar 09-29-2018 16:50:20 09-29-2018 16:51:22
3D 09-29-2018 16:51:22 09-29-2018 16:52:07
Initial Position 10 20 30 40 50 60 70 80 90 100 Radar 1 (-24.29,42) (12,25,34) 1 (-19.79,34) (31,43,17) Product Information COPYRIGHT 2019 Hangzhou Hikvision Digital Technology Co., Ltd. ALL RIGHTS RESERVED. Any and all information, including, among others, wordings, pictures, graphs are the properties of Hangzhou Hikvision Digital Technology Co., Ltd. or its subsidiaries
(hereinafter referred to be Hikvision). This user manual (hereinafter referred to be the Manual) cannot be reproduced, changed, translated, or distributed, partially or wholly, by any means, without the prior written permission of Hikvision. Unless otherwise stipulated, Hikvision does not make any warranties, guarantees or representations, express or implied, regarding to the Manual. About this Manual This Manual is applicable to the Security Radar. The Manual includes instructions for using and managing the product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to rmware updates or other reasons. Please nd the latest version in the company website (http://overseas.hikvision.com/en/). Please use this user manual under the guidance of professionals. Trademarks Acknowledgement and other Hikvisions trademarks and logos are the properties of Hikvision in various jurisdictions. Other trademarks and logos mentioned below are the properties of their respective owners. This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the RE Directive 2014/53/EU, the EMC Directive 2014/30/EU, the LVD Directive 2014/35/EU, the RoHS Directive 2011/65/EU. 2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specic battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see:www.recyclethis.info 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info This product operates in a European non-harmonised frequency band. ISED RSS Warning:
This device complies with Innovation, Science and Economic Development Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'ISED applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. ISED RF exposure statement:
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator& your body.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Le rayonnement de la classe b repecte ISED fixaient un environnement non contrls.Installation et mise en uvre de ce matriel devrait avec changeur distance minimale entre 20 cm ton corps.Lanceurs ou ne peuvent pas coexister cette antenne ou capteurs avec dautres.