all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 5.11 MiB | May 07 2022 | |||
1 |
|
Internal photo | Internal Photos | 1.86 MiB | May 07 2022 | |||
1 |
|
External photo | External Photos | 887.32 KiB | May 07 2022 | |||
1 |
|
Label | ID Label/Location Info | 182.18 KiB | May 07 2022 | |||
1 |
|
Appendix A for 2.4G WiFi | Test Report | 3.70 MiB | May 07 2022 | |||
1 |
|
Applicant Declaration Letter | Cover Letter(s) | 216.72 KiB | May 07 2022 | |||
1 |
|
Auth letter | Cover Letter(s) | 114.75 KiB | May 07 2022 | |||
1 | Block diagram RF | Block Diagram | May 07 2022 | confidential | ||||
1 | Bolckdiagram unit | Block Diagram | May 07 2022 | confidential | ||||
1 |
|
Confidentiality FCC | Cover Letter(s) | 138.55 KiB | May 07 2022 | |||
1 |
|
MCL | Cover Letter(s) | 127.89 KiB | May 07 2022 | |||
1 |
|
MPE | RF Exposure Info | 683.60 KiB | May 07 2022 | |||
1 | Operational description | Operational Description | May 07 2022 | confidential | ||||
1 | Schematics RF | Schematics | May 07 2022 | confidential | ||||
1 | Schematics unit | Schematics | May 07 2022 | confidential | ||||
1 |
|
Setup photo | Test Setup Photos | 975.48 KiB | May 07 2022 | |||
1 |
|
Test report | Test Report | 2.06 MiB | May 07 2022 |
1 | User Manual | Users Manual | 5.11 MiB | May 07 2022 |
Video Intercom Two-Wire Bundle User Manual Video Intercom Two-Wire Bundle User Manual Legal Information 2021 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved. About this Manual The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website ( https://www.hikvision.com/ ). Please use this Manual with the guidance and assistance of professionals trained in supporting the Product. and other Hikvision's trademarks and logos are the properties of Hikvision in various jurisdictions. Other trademarks and logos mentioned are the properties of their respective owners. Trademarks Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED "AS IS" AND "WITH ALL FAULTS AND ERRORS". HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN i Video Intercom Two-Wire Bundle User Manual CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER PREVAILS. ii Video Intercom Two-Wire Bundle User Manual Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Danger Caution Note Indicates a hazardous situation which, if not avoided, will or could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance degradation, or unexpected results. Provides additional information to emphasize or supplement important points of the main text. iii Video Intercom Two-Wire Bundle User Manual Safety Instruction Warning All the electronic operation should be strictly compliance with the electrical safety regulations, fire prevention regulations and other related regulations in your local region. Please use the power adapter, which is provided by normal company. The power consumption cannot be less than the required value. Do not connect several devices to one power adapter as adapter overload may cause over-heat or fire hazard. dismantle the device. Please make sure that the power has been disconnected before you wire, install or When the product is installed on wall or ceiling, the device shall be firmly fixed. If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then please contact the service center. If the product does not work properly, please contact your dealer or the nearest service center. Never attempt to disassemble the device yourself. (We shall not assume any responsibility for problems caused by unauthorized repair or maintenance.) Caution Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment damage). Do not place the device in extremely hot (refer to the specification of the device for the detailed operating temperature), cold, dusty or damp locations, and do not expose it to high electromagnetic radiation. The device cover for indoor use shall be kept from rain and moisture. Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is forbidden (ignorance can cause fire danger). Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfunction however), and affecting the endurance of sensor at the same time. iv Video Intercom Two-Wire Bundle User Manual Please use the provided glove when open up the device cover, avoid direct contact with the device cover, because the acidic sweat of the fingers may erode the surface coating of the device cover. Please use a soft and dry cloth when clean inside and outside surfaces of the device cover, do not use alkaline detergents. Please keep all wrappers after unpack them for future use. In case of any failure occurred, you need to return the device to the factory with the original wrapper. Transportation without the original wrapper may result in damage on the device and lead to additional costs. Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or equivalent type only. Dispose of used batteries according to the instructions provided by the battery manufacturer. Input voltage should meet both the SELV and the Limited Power Source according to 60950-1 standard. The power supply must conform to LPS. The recommended adaptor models and manufacturers are shown as below. Use the attached adapter, and do not change the adaptor randomly. Model Manufacturer Standard ADS-24S-12 1224GPCN G0549-240-050 TS-A018-120015Ec SHENZHEN HONOR ELECTRONIC CO.,LTD SHENZHEN GOSPELL DIGITAL TECHNOLOGY CO.,LTD SHENZHEN TRANSIN TECHNOLOGIES CO., LTD CEE CEE CEE v Video Intercom Two-Wire Bundle User Manual Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. FCC Conditions This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. vi Video Intercom Two-Wire Bundle User Manual EU Conformity Statement This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014/30/EU, RE Directive 2014/53/EU,the RoHS Directive 2011/
65/EU 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info 2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see:www.recyclethis.info Industry Canada ICES-003 Compliance This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
1. this device may not cause interference, and 2. this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploitation est autorise aux deux conditions suivantes :
vii Video Intercom Two-Wire Bundle User Manual 1. l'appareil ne doit pas produire de brouillage, et 2. l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformment la rglementation d'Industrie Canada, le prsent metteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou infrieur) approuv pour l'metteur par Industrie Canada. Dans le but de rduire les risques de brouillage radiolectrique l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonne quivalente (p.i.r.e.) ne dpasse pas l'intensit ncessaire l'tablissement d'une communication satisfaisante. This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. Cet quipement doit tre install et utilis une distance minimale de 20 cm entre le radiateur et votre corps. viii Video Intercom Two-Wire Bundle User Manual Contents 1 About this Maunal ...................................................................................... 1 2 Appearance ................................................................................................ 2 3 Terminal and Wiring Description ................................................................ 7 3.1 Terminal Description ......................................................................................... 7 3.2 Wiring Description ............................................................................................ 9 4 Installation ................................................................................................ 11 4.1 Install Indoor Station ....................................................................................... 11 4.1.1 Configure Indoor Station Address .......................................................... 11 4.1.2 Wall Mounting ........................................................................................ 12 4.2 Install Door Station ......................................................................................... 14 4.2.1 Configure Sub Module Address .............................................................. 14 4.2.2 One-Module Installation ......................................................................... 16 4.2.3 Two-Module Installation ......................................................................... 23 4.2.4 Three-Module Installation ...................................................................... 31 4.2.5 More-Than-Three Module Installation ................................................... 39 4.3 Install Network Distributor .............................................................................. 52 4.4 Install Analog Distributor ................................................................................ 53 5 Activation ................................................................................................. 55 5.1 Connect to Network ........................................................................................ 55 5.1.1 Connect to Wired Network ..................................................................... 55 5.1.2 Connect to Wireless Network ................................................................. 55 5.2 Activate Device via Client Software ................................................................. 55 ix Video Intercom Two-Wire Bundle User Manual 5.3 Activate via SADP ............................................................................................ 56 5.4 Activate Device via Web .................................................................................. 57 6 Remote Configuration via Web ................................................................ 59 6.1 Login and Logout ............................................................................................. 59 6.1.1 Log in the Web ........................................................................................ 59 6.1.2 Logout ..................................................................................................... 59 6.2 Quick Configuration ........................................................................................ 59 6.3 Device Management ....................................................................................... 60 6.4 Configuration .................................................................................................. 60 6.4.1 System Settings ....................................................................................... 61 6.4.2 Network Settings .................................................................................... 63 6.4.3 Intercom Settings .................................................................................... 64 A. Cables ...................................................................................................... 66 B. Communication Matrix and Device Command ....................................... 68 x Video Intercom Two-Wire Bundle User Manual 1 About this Maunal Get the manual and related software from or the official website (http://
www.hikvision.com). Product Model Two-Wire Door Station DS-KD8003-IME2 Two-Wire Indoor Station Network Distributor Analog Distributor DS-KH1201 DS-KAD7040 DS-KAD1040 1 Video Intercom Two-Wire Bundle User Manual 2 Appearance Two-Wire Door Station No. 1 2 3 4 5 6 7 Figure 2-1 Front and Side Panel Table 2-1 Appearance Description Low Illumination IR Supplement Light Description Microphone Built-in Camera Loudspeaker Call Button Nametag TAMPER 2 Video Intercom Two-Wire Bundle User Manual Figure 2-2 Bottom Panel Table 2-2 Appearance Description Description Network Interface Terminals Module-connecting Interface (output) No. 8 9 10 Two-Wire Indoor Station Figure 2-3 Appearance of Indoor Station Table 2-3 Description No. Description 1 2 3 Screen Microphone Volume-
Description Live View/Switch Terminals Loudspeaker No. 8 9 10 3 Video Intercom Two-Wire Bundle User Manual No. Description No. Description Volume+
Receive/Decline Unlock Door 2 Unlock Door 1 11 12 13 14 Four-Wire Terminal DIP Switch Debugging Port Jumper 4 5 6 7 Note The Debugging Port is used for debugging only. Network Distributor Figure 2-4 Appearance of Distributor 4 Video Intercom Two-Wire Bundle User Manual Table 2-4 Description No. Description No. Description Cascade Input & Output
(Reserved) Cascade Channels Power Input Reset Button 5 6 7 8 Network Interface Power Indicator Cascade Indicator Network Interface
(Supports for PoE Output) 1 2 3 4 Note The appearance may vary according to different device models. Refers to the actual device. Analog Distributor Figure 2-5 Appearance of Distributor 5 Video Intercom Two-Wire Bundle User Manual Table 2-5 Description No. Description No. Description 1 2 3 Cascade Output Terminal 1 Cascade Output Terminal 2 Cascade Output Terminal 3 4 5 6 Cascade Output Terminal 4 Two-Wire Input Terminal Two-Wire Output Terminal 6 Video Intercom Two-Wire Bundle User Manual 3 Terminal and Wiring Description 3.1 Terminal Description Two-Wire Main Unit Terminal Figure 3-1 Two-Wire Main Unit Terminal Table 3-1 Descriptions of Terminals and Interfaces No. Interface Description A1 A2 A3 A4 A5 A6 A7 A8 B1 B2 NC1 NO1 COM NC2 NO2 GND GND AIN2 AIN1 12 VDC Door Lock Relay Output (NC) Door Lock Relay Output (NO) Common Interface Door Lock Relay Output (NC) Door Lock Relay Output (NO) Grounding Reserved Grounding 7 For the access of Door Magnetic 2 For the access of Door Magnetic 1 B3 B4 B5 B6 B7 B8 C L1+
L1-
L2+
L2-
Video Intercom Two-Wire Bundle User Manual No. Interface Description For the access of Exit Button 1 For the access of Exit Button 2 Module-connecting Interface AIN3 AIN4 485-
485+
12 V OUT GND Two-Wire Interface Two-Wire Interface Two-Wire Indoor Station Figure 3-2 Terminal of Indoor Station Table 3-2 Descriptions of Terminal and Interfaces Interface Description For the access of BUS For the access of indoor station 8 Video Intercom Two-Wire Bundle User Manual 3.2 Wiring Description Typical application of the system is shown as below. Figure 3-3 Wiring Note Caution Up to 10 indoor stations can be connected hand-by-hand. Up to 150 indoor stations can be connected to one terminal of the distributor. When connecting the doorbells to indoor stations, up to 85 indoor stations can be connected to one terminal of the distributor. Make sure all the related equipment is power-off during the wiring and installation. Two-Wire door station should be connected to CH1 (48 V,15 W) of the distributor with 2-wire cables. Two-Wire Analog Distributor should be connected to any terminal of CH2 to CH5 (48 V,15 W) of the distributor with 2-wire cables. Network door station can be connected to LAN(PoE) of the distributor with Network Cable. 1 distributor can only connect 1 door station to build the communication. The distributor supports standard PoE. 9 Video Intercom Two-Wire Bundle User Manual Note The distributor can only connect 1 door station. Network door station and two-wire door station can not be connected to the distributor at the same time. 10 Video Intercom Two-Wire Bundle User Manual 4 Installation 4.1 Install Indoor Station 4.1.1 Configure Indoor Station Address DIP switches are used to coding the room No. of indoor station. The No. should be unique. The No. of DIP switches from left to right is 1 ~ 10. Figure 4-1 DIP Switch 11 Video Intercom Two-Wire Bundle User Manual Icon Description Table 4-1 Description Represent 1 in binary mode Represent 0 in binary mode For example, binary value of the following status is: 00 0000 1100. And its decimal value is 12. Figure 4-2 Example 4.1.2 Wall Mounting It supports wall mounting. There are two installation modes. 12 Video Intercom Two-Wire Bundle User Manual Before You Start parts are included. Make sure the device in the package is in good condition and all the assembly The power supply the indoor station supports is 48 VDC. Please make sure your power supply matches your indoor station. Make sure all related equipments are power-off during the installation. Check the product specification for the installation environment. There are 2 size of the gang boxes adapted to the device. Size 1: 75 mm (width) 75 mm (length) 50 mm (depth). Size 2: 55 mm (width) 101 mm (length) 38.5 mm (depth). The dimension of mounting plate is shown as below. Figure 4-3 Mounting Plate Steps 1. Cave a hole in the wall. Note The suggested dimension fo the installation hole should be larger than the gang box. 2. Insert a gang box to the hole chiseled on the wall. 3. Fix the wall mounting plate to the gang box with 2 screws. 13 Video Intercom Two-Wire Bundle User Manual Note If you install the device with a gang box (75 mm(width) 75 mm(length) 46 mm(depth)), the left and right holes will be applied. If you install the device with a gang box (55 mm(width) 101 mm(length) 48.5 mm(depth)), the upper and lower holes will be applied. 4. Hook the indoor station to the wall mounting plate tightly by inserting the plate hooks into the slots on the rear panel of the indoor station, during which the lock catch will be locked automatically. Figure 4-4 Wall Mounting 4.2 Install Door Station 4.2.1 Configure Sub Module Address You need to set the sub module address via DIP switch before installation. 14 Video Intercom Two-Wire Bundle User Manual Steps switch. 1. Remove the rubber cover on the rear panel of the sub module to expose the DIP 2. Set the sub module address according to the DIP rules, and install the rubber Figure 4-5 DIP Switch Bit 1, 2, 3, 4 are used to coding the sub module address. Bit 5, 6, 7 are reserved. Set Bit 8 as on to enable a resistance (120). Valid sub module address is from 1 to 8. The address should be unique for connecting to the main unit. The sub module address and its corresponding switch status are displayed as below. Table 4-2 Description 1 2 3 4 5 6 7 8 ON OFF OFF OFF OFF ON OFF OFF ON ON OFF OFF OFF OFF ON OFF ON OFF ON OFF OFF ON ON ON ON ON OFF OFF OFF OFF OFF ON cover back. Note Sub Module Address Bit 1 Bit 2 Bit 3 Bit 4 15 Video Intercom Two-Wire Bundle User Manual 4.2.2 One-Module Installation One-Module Surface Mounting Before You Start Figure 4-6 Mounting Frame The dimension of one module mounting frame (W H D) is: 117 mm 107 mm The dimensions above are for reference only. The actual size can be slightly different from the theoretical dimension. 1. Paste the installation Sticker 1 onto the wall. Make sure the sticker is placed horizontally via measuring with the gradienter. 2. Drill 4 holes according to the screw holes on the sticker. Note 32.7 mm. Steps Note The suggested size of hole is 6 (diameter) 25 (depth) mm. The suggested length of cables left outside is 100 mm. 16 Video Intercom Two-Wire Bundle User Manual Figure 4-7 Drill Screw Holes 3. Remove the stricker and insert the expansion sleeves into the screw holes. 4. Fix the mounting frame onto the wall with 4 expansion bolts. Figure 4-8 Fix the Mounting Frame 17 Video Intercom Two-Wire Bundle User Manual 5. Connect the cables to the corresponding interfaces of the main unit and insert the main unit into the frame. 6. Fix the cover onto the frame. Figure 4-9 Insert the Main Unit Figure 4-10 Fix the Cover One-Module Flush Mounting 18 Video Intercom Two-Wire Bundle User Manual Before You Start Figure 4-11 Front and Side View of the Gang Box Figure 4-12 Gang Box 19 Video Intercom Two-Wire Bundle User Manual Note Steps Note mm. The dimension of one-module gang box is: 115 (W) 134 (H) 56 (D) mm. The dimension is for reference only. 1. Drill an installation hole, and pull the cables out. The suggested dimension of installation hole is 118 (W) 108 (H) 45.5 (D) The suggested length of cables left outside is 100 mm. Figure 4-13 Drill Installation Hole 2. Remove the plastic sheet of the cable entry. 3. Mark the gang box screw holes on the wall. 1) Route the cables through the gang box hole. 2) Insert the gang box into the installation hole. 3) Mark the gang box screw holes' position with a marker, and take out the gang box. 20 Video Intercom Two-Wire Bundle User Manual 4. Drill 4 holes according to marks on the wall, and insert the expansion sleeves into Figure 4-14 Mark the Screw Holes the screw holes. Note The suggested size of the hole is 6 (diameter) 45 (depth) mm. 5. Route the cables through the gang box hole. Insert the gang box into the installation hole. Fix the gang box with 4 expansion bolts. Figure 4-15 Fix the Gang Box 6. Fill the gap between the gang box and the wall with concrete. Remove the 4 mounting ears with tool after concrete is dry. 21 Video Intercom Two-Wire Bundle User Manual Figure 4-16 Remove the Mounting Ears 7. Connect the cables to the corresponding interfaces of the main unit and insert the unit into the gang box. Figure 4-17 Insert the Main Unit 8. Fix the cover and the main unit with 2 socket head cap screws by using a hexagon wrench (supplied). 22 Video Intercom Two-Wire Bundle User Manual Figure 4-18 Fix the Cover 4.2.3 Two-Module Installation Two-Module Surface Mounting Before You Start Figure 4-19 Mounting Frame 23 Video Intercom Two-Wire Bundle User Manual The dimension of two-module mounting frame (W H D) is: 219 mm 107 mm The dimensions above are for reference only. The actual size can be slightly different from the theoretical dimension. Note 32.7 mm. Steps 1. Paste the installation Sticker 1 onto the wall. Make sure the sticker is placed horizontally via measuring with the gradienter. 2. Drill 4 holes according to the screw holes on the sticker. The suggested size of hole is 6 (diameter) 25 (depth) mm. The suggested length of cables left outside is 270 mm. Figure 4-20 Drill Screw Holes 3. Remove the sticker and insert the expansion sleeves into the screw holes. 4. Fix the mounting frame onto the wall with 4 expansion bolts. 24 Video Intercom Two-Wire Bundle User Manual Figure 4-21 Fix the Mounting Frame 5. Thread the module-connecting line across the thread hole of the frame. Pass the main unit connecting lines across the thread hole to the upper grid. 6. Connect the cables. Figure 4-22 Placement of Lines 1) Connect the lines and module-connecting line to the corresponding interfaces of the main unit, then place the main unit into the upper grid. 2) Connect the other end of the module-connecting line to the input interface of the sub module. 25 Video Intercom Two-Wire Bundle User Manual 3) Organize the cable with cable tie in the package. The suggested cable connection picture as shown below. Figure 4-23 Line Connection Effect Picture 7. Insert the modules into the frame after wiring. The main unit must be placed in the top grid. 8. Use the hexagon wrench in the package to fix the cover onto the frame. Figure 4-24 Insert the Modules 26 Video Intercom Two-Wire Bundle User Manual Figure 4-25 Fix the Cover Two-Module Flush Mounting Before You Start Figure 4-26 Gang Box 27 Video Intercom Two-Wire Bundle User Manual Note Steps Note mm. The dimension of two-module gang box is: 237 (W) 134 (H) 56 (D) mm. The dimension is for reference only. 1. Drill the installation hole, and pull the cable out. The suggested dimension of installation hole is 220 (W) 108 (H) 45.5 (D) The suggested length of cables left outside is 270 mm. Figure 4-27 Drill the Installation Hole 2. Select a cable entry and remove the plastic sheet. 3. Mark the gang box screw holes on the hole. 1) Routs the cables through the gang box hole. 2) Insert the gang box into the installation hole. 3) Mark the gang box screw holes' position with a marker, and take out the gang box. 28 Video Intercom Two-Wire Bundle User Manual Figure 4-28 Mark the Screw Holes 4. Drill 4 holes according to the marks on the wall, and insert the expansion sleeves into the screw holes. The suggested size of hole is 6 (diameter) 45 (depth) mm. 5. Fix the gang box with 4 expansion bolts. Figure 4-29 Fix the Gang Box 6. Fill the gap between the gang box and the wall with concrete. Remove the mounting ears with tool after concrete is dry. 29 Video Intercom Two-Wire Bundle User Manual Figure 4-30 Remove the Mounting Ears 7. Connect cables and insert the modules. 1) Connect Cable 1 and one end of Cable 2 to the corresponding interfaces of the main unit, then insert the main unit into the upper grid. 2) Connect the other end of Cable 2 to the input interface of the sub module. Insert it into the lower grid. Figure 4-31 Connect Cables and Insert the Modules 30 Video Intercom Two-Wire Bundle User Manual Note Cable 1 refers to the cables pulled out from the wall that connected to the main unit. Cable 2 refers to the module-connecting line in the accessory package. 8. Fix the cover with 2 socket head cap screws by using a hexagon wrench (supplied). Figure 4-32 Fix the Cover 4.2.4 Three-Module Installation Three-Module Surface Installation Before You Start Figure 4-33 Mounting Frame 31 Video Intercom Two-Wire Bundle User Manual The dimension of two-module mounting frame (W H D) is: 320.8 mm 107 The dimensions above are for reference only. The actual size can be slightly different from the theoretical dimension. Note mm 32.7 mm. Steps 1. Paste the installation sticker 1 onto the wall. Make sure the sticker is placed horizontally via measuring with the gradienter. 2. Drill 4 holes according to the screw holes on the sticker.The suggested size of hole is 6 (diameter) 25 (depth) mm. The suggested length of cables left outside is 270 mm. Figure 4-34 Drill Screw Holes 3. Remove the sticker and insert the expansion sleeves into the screw holes. 4. Fix the mounting frame onto the wall with 4 expansion bolts. 32 Video Intercom Two-Wire Bundle User Manual Figure 4-35 Fix the Mounting Frame Note The mounting frame should be placed exactly as shown below for this step. The tamper plate should be at the low right of the first grid. Figure 4-36 Mounting Frame 5. Thread the module-connecting line across the thread holes of the frame. Pass the main unit connecting line across the thread hole to the top grid. 33 Video Intercom Two-Wire Bundle User Manual 6. Connect the cables. Figure 4-37 Placement of Lines 1) Connect the lines and module-connecting line 1 to the corresponding interfaces of the main unit, then place the main unit into the upper grid. 2) Connect the other end of the module-connecting line 1 to the input interface of the sub module. Connect two sub modules via module-connecting line 2. 3) Organize the cables with cable tie in the package. The suggested cable connection picture as shown below. Figure 4-38 Line Connection Effect Picture 7. Insert the modules into the frame after wiring. The main unit must be placed in the top grid. 34 Video Intercom Two-Wire Bundle User Manual Figure 4-39 Insert the Modules into the Frame 8. Use the hexagon wrench in the package to fix the cover onto the frame. Figure 4-40 Fix the Cover Three-Module Flush Mounting 35 Video Intercom Two-Wire Bundle User Manual Before You Start Figure 4-41 Gang Box The dimension of one-module gang box is: 338.8(W)134(H)56(D) mm. The dimensions above are for reference only. The actual size can be slightly different from the theoretical dimension. Note Steps 1. Cave the installation hole, and pull the cable out.The suggested dimension of installation hole is 321.8(W)108(H)45.5(D) mm. The suggested length of cables left outside is 270 mm. 36 Video Intercom Two-Wire Bundle User Manual Figure 4-42 Cave the Installation Hole 2. Select a cable entry and remove the plastic sheet. 3. Mark the gang box screw holes on the wall. 1) Route the cables through the gang box hole. 2) Insert the gang box into the installation hole. 3) Mark the gang box screw holes' position with a marker, and take out the gang box. Figure 4-43 Mark the Screw Holes 4. Drill 4 holes according to marks on the wall, and insert the expansion sleeves into the screw holes. The suggested size of hole is 6 (diameter) 45 (depth) mm. 5. Fix the gang box with 4 expansion bolts. 37 Video Intercom Two-Wire Bundle User Manual Figure 4-44 Fix the Gang Box 6. Fill the gap between the gang box and wall with concrete. Remove the mounting ears with tool after concrete is dry. Figure 4-45 Remove the Mounting Ears 7. Connect cables and insert the modules. 1) Connect Cable 1 and one end of Cable 2 to the corresponding interfaces of the main unit, then insert the main unit into the upper grid. 2) Connect the other end of Cable 2 to the input interface of Sub Module 1. Connect one end of Cable 3 to the output interface of Sub Module 1 and insert it into the middle grid. 3) Connect the other end of Cable 3 to the input interface of Sub Module 2. Insert it into the bottom grid. 38 Video Intercom Two-Wire Bundle User Manual Figure 4-46 Connect Cables and Insert Modules Note Cable 1 refers to the cables pulled out from the wall that connected to the main unit. Cable 2 and Cable 3 refer to the module-connecting line in the accessory package. 8. Fix the cover and the main unit with 2 socket head cap screws by using a hexagon wrench (supplied). Figure 4-47 Fix the Cover 4.2.5 More-Than-Three Module Installation More-than-Three Module Surface Mounting 39 Video Intercom Two-Wire Bundle User Manual Before You Start Figure 4-48 Mounting Frame It takes two three-module mounting frames. The dimension of three-module mounting frame (W H D) is: 320.8 mm 107 mm 32.7 mm. The dimensions above are for reference only. The actual size can be slightly different from the theoretical dimension. 1. Paste two Sticker 1 onto the wall. Make sure the stickers are placed horizontally via measuring with the gradienter. 2. Drill 8 holes according to the screw holes on the sticker. Note Steps Note The suggested size of hole is 6 (diameter) 25 (depth) mm. The suggested length of cables left outside is 270 mm. 3. Pull out the cable through the cable hole of the left sticker. 40 Video Intercom Two-Wire Bundle User Manual Figure 4-49 Drill Screw Holes 4. Remove the stickers and insert the expansion sleeves into the screw holes. 5. Thread the module-connecting line (400 mm) and grounding line across the thread hole of both frames. Figure 4-50 Place the Grounding Line and Module-Connecting Line 41 Video Intercom Two-Wire Bundle User Manual Note 2. There are 6 module-connecting lines in the package: 190 mm 4 and 400 mm Take the 400 mm module-connecting line for this step. The green-yellow line in the package is for grounding. 6. Fix the mounting frame onto the wall with 8 expansion bolts. Figure 4-51 Fix the Mounting Frame 7. Pass the main unit connecting line across the thread hole to the top grid of the left frame. Thread the module-connecting line (190 mm) across the thread hole of the frame. The lines should be placed as shown below. Figure 4-52 Placement of Lines 42 Video Intercom Two-Wire Bundle User Manual 8. Connect the cables. 1) Connect the cables from the wall and module-connecting line 1 to the corresponding interfaces of the main unit, then place the main unit into the upper grid. 2) Connect the other end of the module-connecting line 1 to the input interface of the sub module. Connect all sub modules via module-connecting lines. 3) Organize the cable with cable tie in the package. The suggested cable connection picture as shown below. Figure 4-53 Line Connection Effect Picture 43 Video Intercom Two-Wire Bundle User Manual 9. Insert the modules into the frame after wiring. The main unit must be placed in the top grid on the left. 10. Pull the grounding line out and fixed its two end to the screw on the cover. Figure 4-54 Insert the Modules Figure 4-55 Connect the Grounding Line to the Cover 11. Use the hexagon wrench in the package to fix the cover onto the frame. 44 Video Intercom Two-Wire Bundle User Manual Figure 4-56 Fix the Cover More-Than-Three Module Flush Mounting 45 Video Intercom Two-Wire Bundle User Manual Before You Start Figure 4-57 Gang Box Note It takes two three-module gang boxes. The dimension of the gang box is: 338.8 (W) 134 (H) 56 (D) mm. The dimension is for reference only. 46 Video Intercom Two-Wire Bundle User Manual Steps 1. Drill the installation hole, and pull the cable out.The suggested dimension of installation hole is 321.8 (W) 315 (H) 45.5 (D) mm. The suggested length of cables left outside is 270 mm. Figure 4-58 Cave the Installation Hole 2. Connect two gang boxes as below. 3. Select a cable entry and remove the plastic sheet. Figure 4-59 Connect Two Gang Boxes 47 Video Intercom Two-Wire Bundle User Manual 4. Remove the plastic sheets on the side of the gang boxes (shown as 1 and 2) below:
Figure 4-60 Remove the Plastic Sheets 5. Mark the gang box screw holes on the wall. 1) Route the cables through the gang box hole. 2) Insert the gang box into the installation hole. 3) Mark the gang box screw holes' position with a marker, and take out the gang box. Figure 4-61 Mark the Screw Holes 48 Video Intercom Two-Wire Bundle User Manual 6. Drill 8 holes according to the marks on the wall, and insert the expansion sleeves into the screw holes. The suggested size of hole is 6 (diameter) 45 (depth) mm. 7. Fix the gang boxes with 8 expansion bolts. Figure 4-62 Fix the Gang Boxes 8. Fill the gap between the gang box and wall with concrete. Remove the mounting ears with tool after concrete is dry. Route the grounding line through the cable entries. Figure 4-63 Remove the Mounting Ears Note The green-yellow line in the package is for grounding. 9. Connect cables and insert the modules. 49 Video Intercom Two-Wire Bundle User Manual 1) Connect Cable 1 and one end of Cable 2 to the corresponding interfaces of the Main Unit, then place the Main Unit into the upper grid of the left gang box. 2) Connect the other end of Cable 2 to the input interface of Sub Module 1. Connect one end of Cable 3 to the output interface of Sub Module 1 and insert it into the middle grid of the left gang box. 3) Finish the wiring and inserting according to the cable number and the position shown as below. Figure 4-64 Install Mounting Frame The cables connect to each module shown as below. Figure 4-65 Cables Connection 50 Video Intercom Two-Wire Bundle User Manual Note Cable 2,3,5 and 6 are the module-connecting lines (190 mm) in the package. Cable 4 is the module-connecting line (400 mm) in the package. Main unit must be put in the top grid. 10. Pull the grounding line out and fixed its two end to the screw on the cover. Figure 4-66 Connect the Grounding Line to the Cover 11. Fix the cover with 2 socket head cap screws by using a hexagon wrench
(supplied). 51 Video Intercom Two-Wire Bundle User Manual Figure 4-67 Fix the Cover 4.3 Install Network Distributor Before You Start Make sure the device in the package is in good condition. Make sure all the related equipment is power-off during the installation. Check the product specification for the installation environment. 1. Fix the DIN rail onto the wall and pull the clip downward. Steps Note You are required to utilize a matched DIN rail. 2. Lock the distributor to the DIN rail. 52 Video Intercom Two-Wire Bundle User Manual Figure 4-68 Wall Mounting 4.4 Install Analog Distributor It supports wall mounting. Before You Start Make sure the device in the package is in good condition. Make sure all the related equipment is power-off during the installation. Check the product specification for the installation environment. Steps holes. 1. Drill 2 holes according to the screw holes, and insert the expansion sleeves to the 53 Video Intercom Two-Wire Bundle User Manual Figure 4-69 Drill Screw Holes Note The suggested size of the hole is 7.5 (diameter) 25 (Depth) mm. 2. Fix the device to the wall with 2 screws. Figure 4-70 Fix the Device 54 Video Intercom Two-Wire Bundle User Manual 5 Activation 5.1 Connect to Network The network distributor supports two ways to connect to network. 5.1.1 Connect to Wired Network You can connect the device to the network via connecting network cables. 1. Use the network cable to connect your computer to distributor. 2. Enter the default IP address of the device in the address bar of web browser. What to do next Activate the device and login to configure parameters remotely. 5.1.2 Connect to Wireless Network The network distributor supports Wi-Fi AP mode. You can connect the device to the network via wireless network. Steps Steps 1. Enable the Wi-Fi AP mode of the device. 2. Connect the computer to distributor via wireless network. 3. Enter any content in the address bar of web browser, the configuration page of the distributor will pop up automatically. What to do next Activate the device and login to configure parameters remotely. 5.2 Activate Device via Client Software You can only configure and operate the door station after creating a password for the device activation. Default parameters of door station are as follows:
55 Video Intercom Two-Wire Bundle User Manual Default IP Address: 192.0.0.65. Default Port No.: 8000. Default User Name: admin. Steps 1. Run the client software, click Maintenance and Management Device Management Device to enter the page. 2. Click Online Device. 3. Select an inactivated device and click Activate. 4. Create a password, and confirm the password. Note Note We highly recommend you to create a strong password of your own choosing
(using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you change your password regularly, especially in the high security system, changing the password monthly or weekly can better protect your product. 5. Click OK to activate the device. When the device is not activated, the basic operation and remote operation of device cannot be performed. You can hold the Ctrl or Shift key to select multiple devices in the online devices, and click the Activate button to activate devices in batch. 5.3 Activate via SADP SADP is a tool to detect, activate and modify the IP address of the device over the LAN. Before You Start Get the SADP software from the supplied disk or the official website http://
www.hikvision.com/ , and install the SADP according to the prompts. The device and the PC that runs the SADP tool should belong to the same subnet. The following steps show how to activate one device and modify its IP address. For batch activation and IP address modification, refer to User Manual of SADP for details. 56 Video Intercom Two-Wire Bundle User Manual Steps 1. Run the SADP software and search the online devices. 2. Find and select your device in online device list. 3. Input new password (admin password) and confirm the password. Caution STRONG PASSWORD RECOMMENDED-We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product. 4. Click Activate to start activation. Status of the device becomes Active after successful activation. 5. Modify IP address of the device. 1) Select the device. 2) Change the device IP address to the same subnet as your computer by either modifying the IP address manually or checking Enable DHCP. 3) Input the admin password and click Modify to activate your IP address modification. 5.4 Activate Device via Web You are required to activate the device first by setting a strong password for it before you can use the device. 57 Video Intercom Two-Wire Bundle User Manual Default parameters of the door station are as follows:
Default IP Address: 192.0.0.65. Default Port No.: 8000. Default User Name: admin Steps enter the activation page. Note 1. Power on the device, and connect the device to the network. 2. Enter the IP address into the address bar of the web browser, and click Enter to The computer and the device should belong to the same subnet. 3. Create and enter a password into the password field. 4. Confirm the password. 5. Click OK to activate the device. 58 Video Intercom Two-Wire Bundle User Manual 6 Remote Configuration via Web 6.1 Login and Logout 6.1.1 Log in the Web After you activate the device and get the IP address, you can access the device via web browser. 1. Open the web browser and input the IP address of the device in the address bar and then press the Enter key to enter the login page. 2. Enter the user name and password. Steps 3. Click Login. 6.1.2 Logout Click Logout on the upper-right of the page to logout. 6.2 Quick Configuration After login the device ,the wizard page will pop up. Configure the parameters quickly to make the devices in the system work properly. Steps 1. Set the network parameters and click Next.
- Edit IPv4 Address, IPv4 Subnet Mask, and IPv4 Default Gateway manually.
- Enable DHCP, the device will get network parameters automatically. 2. Set two-way communication parameters and click Next. 1) Create a Registration Password. 2) Link related device, including Main Door Station IP, Main Station IP and Private Server IP. 3. Set Start Dialing Address, Start Room No., Batch Adding Devices and Batch Adding Floor No. to configure device parameters in batch. 4. Click Complete to enable the settings. 59 Video Intercom Two-Wire Bundle User Manual 6.3 Device Management You can manage the linked device on the page. Click Device Management to enter the settings page. Add Device Click Add to add the indoor station or sub door station. Enter the parameters and click OK to add. Click Import. Enter the information of the device in the template to import devices in batch. Click Export to export the information to the PC. Select the device and click Delete to remove the selected device from the list. Export Delete Refresh Note Click Update Device Status to get the device information. The refreshing will last 1 to 20 minutes, do not power off during the refreshing. Optional: Set Device Information Click to edit device information. Click to delete device information from the list. Select Status to search devices. 6.4 Configuration 60 Video Intercom Two-Wire Bundle User Manual 6.4.1 System Settings Follow the instructions below to configure the system settings, include System Settings, Maintenance, Security, and User Management, etc. Click Configuration System to enter the settings page. Basic Information Click System Settings Basic Information to enter the settings page. On the page, you can edit Device Name and Device No., and select System Type according to your needs. Click Save to enable the settings. View Source Software License Click System Settings About , and click View License to view the source software license. Maintenance Restore Restore All Click Maintenance Upgrade & Maintenance to enter the settings page. Reboot: Click Reboot to reboot the device. Click Default to reset the parameters to the default settings, except the IP parameters and user information. Click Restore All to restore all parameters to default settings. Export parameters:
1. Click Export to pop up the dialog box. 2. Set and confirm the encryption password. 3. Click OK to export parameters. Import Config. File:
1. Click 2. Click Import and enter the encryption password to import. to select the configuration file. Upgrade: Click Browse to select the upgrade file. 61 Video Intercom Two-Wire Bundle User Manual The upgrading process will last 1 to 10 minutes, do not power off during the upgrading. The device reboots automatically after upgrading. Note Security Service Click Security Security Service to enter the settings page. Enable SSH: When the device needs to be debugged in remote, you can slide Enable SSH. If the device needn't to be debugged in remote, you should disable it to improve the device security. After Settings, click Save to enable the settings. Click Security Cerificate Management to enter the settings page. Certificate Management Certificate Files Select Cerificate Type. Import Passwords Click Create and enter the parameters to create certificate files. Select Certificate Type and click to install the certificate file. Import Communication Certificate Select Certificate Type and click to install the certificate file. User Management Click User Management to enter the settings page. Click to modify user password, and click OK to save the settings. Note We highly recommend you to create a strong password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you change your password regularly, especially in the high 62 Video Intercom Two-Wire Bundle User Manual security system, changing the password monthly or weekly can better protect your product. 6.4.2 Network Settings TCP/IP Settings TCP/IP settings must be properly configured before you operate the device over network. The device supports IPv4. Steps 1. Click Network Basic Settings TCP/IP to enter the settings page. 2. Configure the network parameters.
- Check DHCP, the device will get the parameters automatically.
- Set the IPv4 Address, IPv4 Subnet Mask and IPv4 Default Gateway manually. 3. Click Save to enable the settings. Port Settings Steps 2. Set the ports of the device. HTTP Port 1. Click Network Basic Settings Port to enter the settings page. The default port number is 80, and it can be changed to any port No. which is not occupied. The default server port number is 8000, and it can be changed to any port No. ranges from 2000 to 65535. 3. Click Save to enable the settings. Server Port SIP Setting Steps 1. Click Network Basic Settings SIP to enter the settings page. 63 Video Intercom Two-Wire Bundle User Manual Figure 6-1 SIP Settings 2. Check Enable VOIP Gateway. 3. Configure the SIP parameters. 4. Click Save to enable the settings. HTTP Listening Click Configuration Network Advanced HTTP Listening to enter the settings page. Enter the parameters according to the page and click Save to enable the function. Capture Network Packet Click Network Capture Network Packet to enter the settings page. Slide to adjust the Capture Packet Duration and Capture Packet Size. Click Capture to get the network packet. 6.4.3 Intercom Settings Device No. Settings You can set the No. of the device to manage more than two devices. 64 Video Intercom Two-Wire Bundle User Manual Steps 1. Click Configuration Intercom Device No. to enter the settings page. 2. The Device Type is Decoder Station by default. 3. Edit the Communication No., Building No. and Unit No. 4. Click Save to enable settings. Session Settings You can set session to establish the communication between main station with indoor station, outerdoor station, door station or video intercom server. Click Configuration Intercom Session Settings . Set Registration Password, Main Door Station IP, Main Station IP and Private Server IP. Registrater Number Registration Password The register number of the device. It has been set by default. The registration password of the communicated indoor station, outerdoor station, and door station. Main Door Station IP The IP address of main door station. Main Station IP Private Server IP The IP address of main station. The IP address of private server. Click Save. Call Settings Steps You can set the max. call duration and max. message duration of the device. 1. Click Configuration Intercom Call Settings to enter the settings page. 2. Slide to adjust Max. Call Duration and Max. Message Duration. 65 Video Intercom Two-Wire Bundle User Manual A. Cables Cables and Wiring When there are multiple cores in one parallel line, only one pair of closed cores are allowed to transmit signal. It is not allowed to use multiple pair of cores in one cable to transmit signal. When using parallel lines, it is suggested to use those with shielding layer. If dual core or multiple core parallel lines without shielding layer are routed, stability of signal transmission can be effected. You need to run a test before installation. Impedance of cable should not be over suggested value, or distributor cannot transmit enough power to indoor station or door station. Strong electricity and weak electricity cannot be wired in the same route, they need to be wired separately and the distance should be more than 0.5 meter. All the cables used need to follow the restriction in the following table. Routin g Path Twisted Pair Table A-1 Wiring Cables Parallel Lines 17AW G 20AW G 24AW G 23AW G 17AW G 20AW G 24AW G 23AW G DS-
KAD70 40 -
DS-
KD800 3-IME2 Transm ission Distanc e 50 m Transm ission Distanc e 60 m Transm ission Distanc e 35 m Transm ission Distanc e 35 m Transm ission Distanc e 50 m Transm ission Distanc e 50 m Transm ission Distanc e 35 m Transm ission Distanc e 35 m DS-
KAD70 40 -
Transm ission Distanc Transm ission Distanc Transm ission Distanc Transm ission Distanc Transm ission Distanc Transm ission Distanc Transm ission Distanc Transm ission Distanc 66 Video Intercom Two-Wire Bundle User Manual Twisted Pair Parallel Lines e 100 m e 100 m e 100 m e 100 m e 100 m e 90 m e 80 m e 80 m Transm ission Distanc e 200 m Transm ission Distanc e 200 m Transm ission Distanc e 80 m Transm ission Distanc e 100 m Transm ission Distanc e 120 m Transm ission Distanc e 120 m Transm ission Distanc e 80 m Transm ission Distanc e 80 m Routin g Path DS-
KAD10 40 DS-
KAD10 40 -
DS-
KH120 1 Device Installation Installation environment (temperature, moisture etc.) need to follow requirements in specification or power output can be effected. Power consumption of modular door station (main module and sub modules) should be less than 48W. Please reach local technical support if you are not sure about power consumption of each module. Door station should be connected to CH1 of the video/audio distributor. Up to 15 video/audio distributor can be cascaded. If more distributors are needed, you should cascade network switch supporting 1000Mbps. The whole 2-wire system can have up to 600 devices. Power supply must be certified by Hikvision. 67 Video Intercom Two-Wire Bundle User Manual B. Communication Matrix and Device Command Communication Matrix Scan the following QR code to get the device communication matrix. Note that the matrix contains all communication ports of Hikvision access control and video intercom devices. Figure B-1 QR Code of Communication Matrix Device Command Scan the following QR code to get the device common serial port commands. Note that the command list contains all commonly used serial ports commands for all Hikvision access control and video intercom devices. Figure B-2 Device Command 68 UD25519B
1 | Label | ID Label/Location Info | 182.18 KiB | May 07 2022 |
FAIIK VISION Video Audio Distributor Model: DS-KAD7040 UP: 48V=== 1.9A O/P: 48V=== 0.32A for each output SN: AB1234567 Made in China 04/2022 CAN ICES-3(B)/NMB-3(B) FCC ID:2ADTD-KAD7040 1C:20199-KAD7040 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1)this device may not cause harmful interference, and
(2)this device must accept any interference received, including interference that may cause undesired operation. Manufacturer: Hangzhou Hikvision Digital Technology Co.,Ltd. Address: No.555 Qianmo Road, Binjiang District,Hangzhou 310052, China Tyeeeueeeee Beeeeeeeeee
1 | Applicant Declaration Letter | Cover Letter(s) | 216.72 KiB | May 07 2022 |
a) b) c) d) e) f) g) SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Declaration Applicant Legal Business Name Hangzhou Hikvision Digital Technology Co., Ltd. No. 555 Qianmo Road, Binjiang District, Hangzhou 310052, China Address Grantee Code FCC ID Contact Email Contact Phone Authorized Contact Name Long Cheng 2ADTD 2ADTD-KAD7040 chenglong6@hikvision.com
+8618969187825 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare;
in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for:
labeling the equipment with the exact FCC ID as specified in this application,
(1)
(2) compliance statement labeling pursuant to the applicable rules,
(3) compliance of the equipment with the applicable technical rules, if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCCs technical requirements. in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. in accordance with ISO17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements.
(1)
(2)
(3) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. the Applicant shall, upon request by SGS, at the Applicants expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a party for these purposes. the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Date: 2022-04-22 Applicant Signature:
Print Name:
Title:
*NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database Long Cheng Testing & Certification Engineer Applicant Declaration Rev:0.0
1 | Auth letter | Cover Letter(s) | 114.75 KiB | May 07 2022 |
Hangzhou Hikvision Digital Technology Co., Ltd. TO:
Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Date: 2022-04-22 Regarding: FCC ID: 2ADTD-KAD7040 To whom it may concern:
We, the undersigned, hereby authorize Parlam Zhan to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with Hangzhou Hikvision Digital Technology Co., Ltd. This authorization is valid until further written notice from the applicant. Name (Printed): Long Cheng Signature:
On behalf of Company: Hangzhou Hikvision Digital Technology Co., Ltd. Telephone: +8618969187825 Title: Testing & Certification Engineer
1 | Confidentiality FCC | Cover Letter(s) | 138.55 KiB | May 07 2022 |
Confidentiality Request regarding application for FCC ID: 2ADTD-KAD7040 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States Hangzhou Hikvision Digital Technology Co., Ltd. To:
From: Hangzhou Hikvision Digital Technology Co., Ltd. No. 555 Qianmo Road, Binjiang District, Hangzhou 310052, China Regarding:
LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commissions rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. Sincerely, Signature:
Printed Name (on file with the FCC associated with the Grantee Code): Long Cheng Title: Testing & Certification Engineer Company Name: Hangzhou Hikvision Digital Technology Co., Ltd.
1 | MCL | Cover Letter(s) | 127.89 KiB | May 07 2022 |
Hangzhou Hikvision Digital Technology Co., Ltd. Current Date: 2022-04-22 To:
Dear Sir/Madam, SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. No. 588 West Jindu Road, Songjiang District, Shanghai, China. 201612 Subject: Declaration Letter about Identity of Products
*WE (Hangzhou Hikvision Digital Technology Co., Ltd.) HEREBY DECLARED THAT Product Description Video Audio Distributor Model No. DS-KAD7040UHK, DS-KAD7040CKV, DS-KAD7040UVS, Manufacturers Name Hangzhou Hikvision Digital Technology Co., Ltd. DS-KAD7040KVO, DS-KAD7040HUN Manufacturers Address No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
*Except that the model number, trade name, color and appearance deviation, are identical with the original product as follows:
Note: The definition of identical should be electrically identical. A device will be considered to be electrically identical if no changes are made to the devices schematics, board layouts, component layouts, chip sets, resistors and all other electrical aspects of the device are identical. Model No. ():
DS-KAD7040 Manufacturers Name (): Hangzhou Hikvision Digital Technology Co., Ltd. Manufacturers Address ):
No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China Sincerely, Signature ():
Printed Name ():
Long Cheng Position/Title ():
Testing & Certification Engineer Contact Number ():
+8618969187825
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2022-05-07 | 2422 ~ 2452 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2022-05-07
|
||||
1 | Applicant's complete, legal business name |
Hangzhou Hikvision Digital Technology Co., Ltd.
|
||||
1 | FCC Registration Number (FRN) |
0024149825
|
||||
1 | Physical Address |
No. 555 Qianmo Road, Binjiang District
|
||||
1 |
Hangzhou, N/A
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
U******@SGS.COM
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2ADTD
|
||||
1 | Equipment Product Code |
KAD7040
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
L******** C********
|
||||
1 | Telephone Number |
+8618********
|
||||
1 | Fax Number |
+86-5********
|
||||
1 |
c******@hikvision.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
SGS-CSTC Standards Technical Services Co., Ltd.
|
||||
1 | Name |
P******** Z********
|
||||
1 | Physical Address |
588 West Jindu Road, Xinqiao, Songjiang
|
||||
1 |
ShangHai, 201612
|
|||||
1 |
China
|
|||||
1 | Telephone Number |
+8621********
|
||||
1 | Fax Number |
02161********
|
||||
1 |
P******@sgs.com
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
SGS-CSTC Standards Technical Services Co., Ltd.
|
||||
1 | Name |
P****** Z******
|
||||
1 | Physical Address |
588 West Jindu Road, Xinqiao, Songjiang
|
||||
1 |
ShangHai, 201612
|
|||||
1 |
China
|
|||||
1 | Telephone Number |
+8621********
|
||||
1 | Fax Number |
02161********
|
||||
1 |
P******@sgs.com
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Video Audio Distributor | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter evaluation procedures as documented in this filing. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz and 40MHz bandwidth mode. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Compliance Certification Services (Kunshan) Inc.
|
||||
1 | Name |
J****** C********
|
||||
1 | Telephone Number |
+ 86-******** Extension:
|
||||
1 |
J******@sgs.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2412 | 2462 | 0.035 | ||||||||||||||||||||||||||||||||||||
1 | 2 | 15C | 2422 | 2452 | 0.013 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC