DS-PD1-EB-WS2 Wireless Panic Button A Appearance This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the RE Directive 2014/53/EU, the EMC Directive 2014/30/EU, the LVD Directive 2014/35/EU, the RoHS Directive 2011/65/EU. E N G L I S H Diagram References:
A B C C D Appearance Description Register Panic Button Locally Register Panic Button Locally via APP LEDs : General LEDs
(i) From power up: Not learnt
(ii) Learning process
(iii) 8 x Flashes: Learnt
(iv) 18 x Slow ashes: Fault with new battery installed
(v) Signal strength sent to control panel
(vi) Hold up alarm has been activated
(vii) Control panel has not received the signal from HUD Specication Setting devices technical characteristics Hold-up function LED indication Yes Red, Amber, Green
Operating temperature Dimensions (H x W x D) Environmental and operating features
-10C to +40C 72 x 30 x 20 mm Electrical & battery Transmission frequency Range in open space Battery type Battery voltage Threshold 433.6MHZ 300m CR1/3N 3V 2.1V +/- 5%
Certications and warranty Electrical conformity Warranty CE 2 years Battery Information The battery supplied has been chosen to provide long service life whilst, for safety reasons, having limited output current. When disposing of the product, the battery must be disposed of separately in accordance with the local regulations. removed and Indicator Panic Button Panic Button Please register the device winthin 90 seconds after it being powered on. B Learn Panic Button onto Control Panel C Learn Panic Button via APP D LEDs - General LEDs Control Panel With in 50cm Register Detector 1. Make the security control panel enter the registration mode. 2. Register the panic button: Hold any one of the buttons until the two LEDs ash alternately. The green LED will ash 8 times if the registration is nished. 3. Communication Test: press the button to trigger the alarm . Note: The distance between the security control panel and the detector should be less than 50 cm. Unregister Detector Initialize the Detector 1. Remove the battery to power the panic button o. 2. Hold any of the buttons and reinstall the battery to power the detector on at the same time. Release the button while the two LEDs ash once together. When the initialization is completed, the indicator turns to alternately ashing red and green. 1 Log in to the APP Store and input Hik-Connect to search the mobile client. 2 Download and install Hik-Connect to your phone. 3 After installing, tap to run the client. 4 Power on the security control panel. 5 Log in the Hik-Connect and ap the icon + at the upper-right coner of the Hik-Connect page to add the security control panel. You can scan the QR code on the device rear panel or on the package box, or input the device serial No. manually to add the device when the device is in the registration mode. 6 After adding the security control panel, tap the arming status icon on the right of the security control panels name to enter the Partition page. 7 Tap the + icon on the Partition page to add the peripherals.
(i) From power up:
Not learnt
(ii) Learning process
(iii) 8 x ashes: Learnt
(iv) 18 x Slow ashes:
Fault with new battery installed
(vi) Panic alarm has been triggered
(vii) Control panel has not received the signal from HUD
. Product Information FCC Information User Manual COPYRIGHT 2018 Hangzhou Hikvision Digital Technology Co., Ltd. ALL RIGHTS RESERVED. Any and all information, including, among others, wordings, pictures, graphs are the properties of Hangzhou Hikvision Digital Technology Co., Ltd. or its subsidiaries (hereinafter referred to be Hikvision). This user manual (hereinafter referred to be the Manual) cannot be reproduced, changed, translated, or distributed, partially or wholly, by any means, without the prior written permission of Hikvision. Unless otherwise stipulated, Hikvision does not make any warranties, guarantees or representations, express or implied, regarding to the Manual. About this Manual This manual is applicable to Panic Buton. The Manual includes instructions for using and managing the product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to rmware updates or other reasons. Please nd the latest version in the company website
(http://overseas.hikvision.com/en/). Please use this user manual under the guidance of professionals. Trademarks Acknowledgement and other Hikvisions trademarks and logos are the properties of Hikvision in various jurisdictions. Other trademarks and logos mentioned below are the properties of their respective owners. FCC Information Please take attention that changes or modication not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Conditions This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation